Influence of temperature on fouling removal for pipeline based on eco-friendly ultrasonic guided wave technology

被引:5
作者
Huang, Mingkun [1 ]
Han, Cong [1 ]
An, Yang [1 ,2 ]
Qu, Zhigang [1 ,2 ]
Chen, Chuanxian [1 ]
Yin, Wuliang [3 ]
机构
[1] Tianjin Univ Sci & Technol, Coll Elect Informat & Automat, 1038 Dagunan Rd, Tianjin 300222, Peoples R China
[2] Tianjin Univ Sci & Technol, Adv Struct Integr Int Joint Res Ctr, 1038 Dagunan Rd, Tianjin 300222, Peoples R China
[3] Univ Manchester, Sch Elect & Elect Engn, Sackville St Bldg, Manchester M13 9PL, Lancs, England
基金
中国国家自然科学基金;
关键词
Ultrasonic guided waves; Sound pressure; Pipeline descaling; Cavitation threshold; Eco-friendly; HEAT-EXCHANGER; CACO3; WATER;
D O I
10.1007/s10098-022-02438-3
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
When industrial pipelines are used to transport production materials, the scale can easily form on the inner wall of a pipeline due to long-term contact with the liquid medium. Scaling in industrial pipelines is a common problem that poses a great threat to the production process and environmental protection. In this paper, the influence of temperature on the fouling removal process in pipes is studied. A finite element simulation model was established for guided wave propagation in pipes with different temperatures to obtain the acoustic pressure distribution along the pipes, showing that when the temperature increases, the acoustic pressure value on the solid-liquid surface of the pipes increases, and the cavitation threshold decreases. The experimental system for pipe descaling at different temperatures was established, when the temperature is from 20 to 60 degrees C, the descaling rate in the inner wall of the pipe far from the transducer is increased from 77.49 to 93.71%, the descaling rate in the inner wall of the pipe near the transducer is increased from 87.01 to 97.02%. The experimental results showed that the descaling performance is better when the pipeline temperature is higher.Compared with the traditional technology, the pipeline descaling technology based on ultrasonic guided waves is highly efficient, safe and eco-friendly, which can remove the fouling inside pipeline online without affecting the transportation. The above conclusions could provide a reference for further popularizing the application of the descaling technology based on ultrasonic guided wave. [GRAPHICS] .
引用
收藏
页码:1211 / 1221
页数:11
相关论文
共 28 条
  • [2] Experimental fouling investigation with electroless Ni-P coatings
    Al-Janabi, A.
    Malayeri, M. R.
    Mueller-Steinhagen, H.
    [J]. INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2010, 49 (06) : 1063 - 1071
  • [3] Water integration in industrial zones: a spatial representation with direct recycle applications
    Alnouri, Sabla Y.
    Linke, Patrick
    El-Halwagi, Mahmoud
    [J]. CLEAN TECHNOLOGIES AND ENVIRONMENTAL POLICY, 2014, 16 (08) : 1637 - 1659
  • [4] Erosion-corrosion of stainless steels, titanium, tantalum and zirconium
    Bermúdez, MD
    Carrión, FJ
    Martínez-Nicolás, G
    López, R
    [J]. WEAR, 2005, 258 (1-4) : 693 - 700
  • [5] Laboratory and prediction of barium sulfate scaling at high-barium formation water
    BinMerdhah, Amer Badr
    Yassin, Abu Azam Mohd
    Muherei, Mazen Ahmed
    [J]. JOURNAL OF PETROLEUM SCIENCE AND ENGINEERING, 2010, 70 (1-2) : 74 - 83
  • [6] Kinetics study of barium sulphate surface scaling and inhibition with a once-through flow system
    Bukuaghangin, Ogbemi
    Sanni, Olujide
    Kapur, Nikil
    Huggan, Michael
    Neville, Anne
    Charpentier, Thibaut
    [J]. JOURNAL OF PETROLEUM SCIENCE AND ENGINEERING, 2016, 147 : 699 - 706
  • [7] Clean technologies: design aspects
    Bulatov, Igor
    Klemes, Jiri
    [J]. CLEAN TECHNOLOGIES AND ENVIRONMENTAL POLICY, 2010, 12 (02) : 87 - 90
  • [8] Towards cleaner technologies: emissions reduction, energy and waste minimisation, industrial implementation
    Bulatov, Igor
    Klemes, Jiri
    [J]. CLEAN TECHNOLOGIES AND ENVIRONMENTAL POLICY, 2009, 11 (01) : 1 - 6
  • [9] Modeling of condensation heat transfer of pure refrigerants in micro-fin tubes
    Chamra, LM
    Mago, PJ
    Tan, MO
    Kung, CC
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2005, 48 (07) : 1293 - 1302
  • [10] Impact of Deposit Aging and Surface Roughness on Thermal Fouling: Distributed Model
    Coletti, F.
    Ishiyama, E. M.
    Paterson, W. R.
    Wilson, D. I.
    Macchietto, S.
    [J]. AICHE JOURNAL, 2010, 56 (12) : 3257 - 3273