Research on a new method of "blocking-sealing" dust control and removal in fully mechanized heading face

被引:25
|
作者
Xie, Sen [1 ,2 ,3 ]
Yu, Haiming [1 ,2 ,3 ]
Ye, Yuxi [1 ,2 ,3 ]
Zhao, Junwei [1 ,2 ,3 ]
Hou, Chuangen [1 ,2 ,3 ]
Zhao, Dongliang [1 ,2 ,3 ]
机构
[1] Shandong Univ Sci & Technol, Coll Safety & Environm Engn, Qingdao 266590, Peoples R China
[2] Shandong Univ Sci & Technol, State Key Lab Min Disaster Prevent & Control Cofoo, Qingdao 266590, Peoples R China
[3] Shandong Univ Sci & Technol, Minist Sci & Technol, Qingdao 266590, Peoples R China
基金
中国国家自然科学基金;
关键词
Fully mechanized heading face; Blocking-sealing; Local dust control; Dust pollution; Negative pressure dust removal; NUMERICAL-SIMULATION; AIR-FLOW; POLLUTION CHARACTERISTICS; CONTROL TECHNOLOGY; RESPIRABLE DUST; CAVING FACE; MINING FACE; COAL-DUST; DIFFUSION; FIELD;
D O I
10.1016/j.energy.2023.129031
中图分类号
O414.1 [热力学];
学科分类号
摘要
The fully mechanized heading face has the disadvantages of a large open space, difficult to seal, and low dust reduction efficiency. To overcome these issues, a new "blocking-sealing" method for cutting the produced dust was proposed in this study. The impact mechanism of ventilation parameters on dust pollution was analyzed using the CFD-DPM method. The results show that in the original state, the transverse offset airflow generated by the roller of the heading machine carries high-concentration dust into the sidewalk space, the length of the highconcentration dust area of more than 570 mg/m(3) in the sidewalk space is about 16 m. After using the new method, the distribution of airflow mechanical energy between the sidewalk space and the bracket-coal wall space was redistributed. When the air suction volume was 600 m(3)/min, the high-concentration dust area basically disappeared. By increasing the air volume ratio to 1:1.5, the dust concentration in the original highconcentration dust area of the sidewalk space was basically lower than 172 mg/m(3). When the side opening of the dust exhaust duct for suction (SO), the dust removal efficiency in the local area of the sidewalk reached 80.7%, which provides a new method for clean coal production.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Research on multi-radial swirling flow for optimal control of dust dispersion and pollution at a fully mechanized tunnelling face
    Hua, Yun
    Nie, Wen
    Wei, Wenle
    Liu, Qiang
    Liu, Yanghao
    Peng, Huitian
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2018, 79 : 293 - 303
  • [22] Law of respirable dust pollution induced by cutting-advancing support in a fully mechanized mining face and spatial stereoscopic dust control and removal technology
    Song, Shuzheng
    Zhou, Gang
    Sun, Biao
    Zhou, Genru
    Wei, Honglei
    Wang, Yunna
    Fu, Zhenkun
    Liu, Zhen
    Meng, Long
    ENVIRONMENT DEVELOPMENT AND SUSTAINABILITY, 2024,
  • [23] The Study of Ventilation Dust Removal System in fully mechanized caving face with large inclination based on Fluent
    Lu Guang-li
    Yao Xi-wen
    Li Xing
    3RD INTERNATIONAL WORKSHOP ON MINE HAZARDS PREVENTION AND CONTROL, 2013, 94 : 134 - 139
  • [24] Research on dust dispersion law of fully mechanized mining faces under different inclinations and tracking closed dust control method
    Zhou, Gang
    Kong, Yang
    Meng, Qunzhi
    Jiang, Bingyou
    Liu, Yongwei
    Li, Gang
    Sun, Biao
    Wang, Jinli
    Yan, Dong
    Li, Zhenhua
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [25] Numerical simulation and field test of dust control effect of exhaust ventilation in fully mechanized face
    Ma, Wei
    Mo, Jinming
    3RD INTERNATIONAL CONFERENCE ON AIR POLLUTION AND ENVIRONMENTAL ENGINEERING, 2020, 631
  • [26] Analysis on dust prevention law of new barrier strategy in fully mechanized coal mining face
    Zhao, Junwei
    Yu, Haiming
    Dong, Hui
    Xie, Sen
    Cheng, Yu
    Xia, Zongwei
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2024, 187 : 1527 - 1539
  • [27] Ventilation dust removal system in high inclination-angle fully mechanized caving face based on FLUENT
    Yao, Xi-Wen
    Lu, Guang-Li
    Xu, Kai-Li
    Wang, Yan-Tong
    Dongbei Daxue Xuebao/Journal of Northeastern University, 2014, 35 (10): : 1497 - 1501
  • [28] Study on spray dust removal law for cleaner production at fully mechanized mining face with large mining height
    Xie, Yao
    Cheng, Weimin
    Yu, Haiming
    Wang, Yuhuan
    POWDER TECHNOLOGY, 2021, 389 : 48 - 62
  • [29] Study on the Atomization and Dust-Reduction Performance of a New Type of External Pneumatic Vortex Fog Curtain Dust Removal Device in Fully Mechanized Excavation Face
    Jing, Deji
    An, Rina
    Chen, Jingxu
    Ge, Shaocheng
    Sun, Liying
    ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2020, 2020
  • [30] Dust-laying method of coal seam water infusion on fully-mechanized caving face
    Cheng Weimin
    Wu Lirong
    Zhou Gang
    Zheng Yangxin
    Wang Gang
    Guo Yanpei
    Guo Yunxiang
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL 6, PTS A AND B, 2006, 6 : 1707 - 1711