Shear bond strength of adhesive precoated brackets: A comparative in vitro study

被引:2
|
作者
Miller, Mary [1 ]
Mon, Htwe H. [2 ]
Xu, Xiaoming [2 ]
Chapple, Andrew [3 ]
Dupree, Peter [4 ]
Ballard, Richard W. [1 ]
Armbruster, Paul [1 ]
机构
[1] LSU Hlth New Orleans, Sch Dent, Dept Orthodont, 1100 Florida Ave, New Orleans, LA 70119 USA
[2] LSU Hlth New Orleans, Sch Dent, Dept Prosthodont, 1100 Florida Ave, New Orleans, LA 70119 USA
[3] LSU Hlth New Orleans, Sch Publ Hlth, Dept Biostat, 2020 Gravier St, New Orleans, LA 70112 USA
[4] LSU Hlth New Orleans, Sch Dent, Dept Comprehens Dent, 1100 Florida Ave, New Orleans, LA 70119 USA
关键词
Shear bond strength; Adhesives; Adhesive precoated; brackets; Orthodontic brackets; SELF-ETCHING PRIMER; ORTHODONTIC BRACKETS; SYSTEMS;
D O I
10.1016/j.ortho.2023.100752
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective > This study compared the shear bond strength of orthodontic precoated brackets from different manufacturers. Methods > Sixty extracted human premolar teeth were divided into six groups (n = 10). The groups were bonded with one of the following brackets: 3MTM Unitek VictoryTM SeriesTM with APC, 3MTM Unitek ClarityTM Advanced CeramicTM with APC, TP Nu-Edge (R) NX Cobalt-Chromium and TP In-Vu (R) ceramic Readi-Base (R) both with eXact (R) orthodontic adhesive, 3MTM Unitek Clarity Advanced CeramicTM and 3MTM Unitek VictoryTM SeriesTM both with TransbondTM XT Adhesive. Each group was tested for shear bond strength using a universal testing machine. Each sample was observed under a dissecting microscope and received an adhesive remnant index (ARI) score. Statistical analysis was performed using Tukey's Standardized Range (HSD) Test to make comparisons among all groups and a Wilcoxon rank-sum test to evaluate for pairwise comparisons between the groups. The P-values < 0.05 were considered significant. Results > The ceramic control was not statistically different from the metal control, 3MTM VictoryTM APCTM, TP In-Vu (R) ceramic eXact (R) or TP Nu-EDGE (R) eXact (R) in terms of shear bond strength (7.69 +/- 1.41 MPa, 7.72 +/- 1.25 MPa, 8.70 +/- 1.93 MPa, 4.90 +/- 1.76 MPa, 5.33 +/- 0.78 MPa, respec-tively). However, it was statistically different from 3MTM Ceramic APCTM (10.29 +/- 2.78 MPa). In terms of modulus, there were no statistical differences. TP's Nu-edge (R) had the lowest average ARI score, but was not statistically different when compared to the other groups. Conclusion > 3MTM Unitek's Ceramic APC had a statistically higher SBS than the non-precoated brackets and TP Orthodontics' precoated brackets. However, all SBS were 4.9 MPA or above, which is deemed clinically acceptable in terms of laboratory forces. There was no statistical difference between manufacturing companies or precoated vs. non-precoated modulus and ARI scores.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] INFLUENCE OF DENTAL EROSION ON SHEAR BOND STRENGTH OF CERAMIC BRACKETS BONDED WITH TWO DIFFERENT ADHESIVE SYSTEMS: AN IN VITRO STUDY
    Menezes-Junior, Laerte Ribeiro
    Vieira Bittencourt, Marcos Alan
    Fernandes Vilela, Andomar Bruno
    Soares, Carlos Jose
    Nobrega, Diego Figueiredo
    de Melo Marinho, Renata Marques
    Rode, Sigmar de Mello
    Salata Nahsan, Flavia Pardo
    Paranhos, Luiz Renato
    BIOSCIENCE JOURNAL, 2021, 37
  • [22] Comparison of the shear bond strength of new and recycled metallic brackets using different adhesive materials. An in vitro study
    Ibarra, R. Nicole
    Saez, Mackarena
    Rojas, Victor
    Oyonarte, Rodrigo
    EUROPEAN ORAL RESEARCH, 2023, 57 (02) : 96 - 102
  • [23] Does the Seating Force Affect the Shear Bond Strength of Brackets? An In Vitro Study
    Sokucu, Oral
    Yesildal, Seher
    Oksayan, Ridvan
    Simsek, Irfan
    TURKISH JOURNAL OF ORTHODONTICS, 2016, 29 (01) : 6 - 9
  • [24] Effects of Ultrasonic Instrumentation on the Shear Bond Strength of Ceramic Brackets: An In Vitro Study
    Rajamanickam, Preethi
    Ramasamy, Navaneethan
    JOURNAL OF ADVANCED ORAL RESEARCH, 2023, 14 (01) : 81 - 87
  • [25] Effect of bonding protocol on shear bond strength of orthodontic brackets: An in vitro study
    Munhoz, Tais
    MATERIA-RIO DE JANEIRO, 2014, 19 (03): : 212 - 217
  • [26] A comparative study of shear bond strength according to sandblasting on recycled brackets.
    Lee, YH
    Nahm, DS
    JOURNAL OF DENTAL RESEARCH, 2000, 79 (05) : 1273 - 1273
  • [27] Shear bond strength of a new dental adhesive used to bond brackets to unetched enamel
    Harari, D
    Gillis, I
    Redlich, M
    EUROPEAN JOURNAL OF ORTHODONTICS, 2002, 24 (05) : 519 - 523
  • [28] Evaluation of shear bond strength and adhesive remnant index of metal APC™ Flash-Free adhesive system: A comparative in vitro study with APC™ II and uncoated metal brackets
    Akl, Roula
    Ghoubril, Joseph
    Le Gall, Michel
    Shatila, Rania
    Philip-Alliez, Camille
    INTERNATIONAL ORTHODONTICS, 2022, 20 (04)
  • [29] The Shear Bond Strengths of Metal and Ceramic Brackets: An in-Vitro Comparative Study
    Reddy, Y. G.
    Sharma, Rohit
    Singh, Ammandeep
    Agrawal, Vishal
    Agrawal, Vijay
    Chaturvedi, Saurab
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2013, 7 (07) : 1495 - 1497
  • [30] An in vitro study of orthodontic brackets bonded to transition dental zirconia: Shear bond strength, adhesive remnant index, and surface irregularities
    Roberts, Gabrielle
    Xu, Xiaoming
    Kee, Edwin
    Chapple, Andrew
    Bartels, Virgil
    Armbruster, Paul
    Ballard, Richard
    INTERNATIONAL ORTHODONTICS, 2025, 23 (01)