Treatment of severe tricuspid regurgitation induced by permanent pacemaker lead: Transcatheter tricuspid valve replacement with the guidance of 3-dimensional printing

被引:13
作者
Mao, Yu [1 ]
Liu, Yang [1 ]
Meng, Xin [2 ]
Ma, Yanyan [1 ]
Li, Lanlan [1 ]
Zhai, Mengen [1 ]
Jin, Ping [1 ]
Lu, Fanglin [3 ]
Yang, Jian [1 ]
机构
[1] Air Force Med Univ, Xijing Hosp, Dept Cardiovasc Surg, Xian, Peoples R China
[2] Air Force Med Univ, Xijing Hosp, Dept Ultrasound Med, Xian, Peoples R China
[3] Naval Mil Med Univ, Changhai Hosp, Dept Cardiovasc Surg, Shanghai, Peoples R China
基金
国家重点研发计划;
关键词
tricuspid regurgitation; transcatheter tricuspid valve replacement; 3-Dimensional printing; LuX-Valve; permanent pacemaker implantation; 1ST-IN-MAN EXPERIENCE; OUTCOMES; REPAIR; INTERVENTIONS; LOCATION; PATIENT; SYSTEM;
D O I
10.3389/fcvm.2023.1030997
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundLead-induced tricuspid regurgitation is one of the complications after permanent pacemaker implantation (PPI) and refers to tricuspid regurgitation (TR) caused by the lead in the right ventricle (RV).ObjectivesTo study the clinical characteristics of severe TR after PPI and the effect of transcatheter tricuspid valve replacement (TTVR) with the guidance of 3-dimensional (3D) printing.MethodsThis study was a single-center, descriptive study. Six patients with severe TR after PPI were enrolled in Xijing Hospital from January 2020 to May 2020. Before TTVR, the 3D printed tricuspid valve (TV) model was used for evaluation in the bench test. LuX-Valve was implanted under the guidance of TEE and x-ray fluoroscopy, and all patients underwent transatrial access. Six patients' data were collected at baseline, before discharge, and 6 months, 1 year and 2 years after TTVR.ResultsThe LuX-Valve was successfully implanted in 6 patients, TR was significantly reduced to <= 2+, and no deaths or cardiopulmonary bypass occurred during procedures. Three cases were caused by TV expansion: Patient #4 had TR caused by lead adhesion to TV, Patient #2 had TR caused by lead winding, and Patient #6 had TR caused by lead impingement on TV. During the 2-year follow-up, TTE revealed that 5 patients had no/trace regurgitation, and one patient (Patient #5) had mild regurgitation. All 6 patients (100.0%) reached primary endpoints.ConclusionTTVR guided by 3D printing is safe and effective in the treatment of severe TR associated with permanent pacemaker lead, providing prospects and possibilities for the precise treatment of TV-related diseases.
引用
收藏
页数:13
相关论文
共 31 条
[1]   Impact of Implantable Transvenous Device Lead Location on Severity of Tricuspid Regurgitation [J].
Addetia, Karima ;
Maffessanti, Francesco ;
Mediratta, Anuj ;
Yamat, Megan ;
Weinert, Lynn ;
Moss, Joshua D. ;
Nayak, Hemal M. ;
Burke, Martin C. ;
Patel, Amit R. ;
Kruse, Eric ;
Jeevanandam, Valluvan ;
Mor-Avi, Victor ;
Lang, Roberto M. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2014, 27 (11) :1164-1175
[2]   Tricuspid Regurgitation and Implantable Devices [J].
Al-Bawardy, Rasha ;
Krishnaswamy, Amar ;
Rajeswaran, Jeevanantham ;
Bhargava, Mandeep ;
Wazni, Oussama ;
Wilkoff, Bruce ;
Tuzcu, Emin Murat ;
Martin, David ;
Thomas, James ;
Blackstone, Eugene ;
Kapadia, Samir .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2015, 38 (02) :259-266
[3]   Tricuspid Regurgitation in Patients With Pacemakers and Implantable Cardiac Defibrillators: A Comprehensive Review [J].
Al-Bawardy, Rasha ;
Krishnaswamy, Amar ;
Bhargava, Mandeep ;
Dunn, Justin ;
Wazni, Oussama ;
Tuzcu, E. Murat ;
Stewart, William ;
Kapadia, Samir R. .
CLINICAL CARDIOLOGY, 2013, 36 (05) :249-254
[4]   Tricuspid Regurgitation Following Implantation of a Pacemaker/Cardioverter-Defibrillator [J].
Al-Mohaissen, Maha A. ;
Chan, Kwan Leung .
CURRENT CARDIOLOGY REPORTS, 2013, 15 (05)
[5]   Management and Outcomes of Transvenous Pacing Leads in Patients Undergoing Transcatheter Tricuspid Valve Replacement [J].
Anderson, Jason H. ;
McElhinney, Doff B. ;
Aboulhosn, Jamil ;
Zhang, Yulin ;
Ribichini, Flavio ;
Eicken, Andreas ;
Whisenant, Brian ;
Jones, Thomas ;
Kornowski, Ran ;
Dvir, Danny ;
Cabalka, Allison K. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (17) :2012-2020
[6]   Case report: Pacemaker lead perforation of a papillary muscle inducing severe tricuspid regurgitation [J].
Andreas, Martin ;
Gremmel, Franz ;
Habertheuer, Andreas ;
Rath, Claus ;
Oeser, Claudia ;
Khazen, Cesar ;
Kocher, Alfred .
JOURNAL OF CARDIOTHORACIC SURGERY, 2015, 10
[7]   Tricuspid regurgitation diagnosis and treatment [J].
Arsalan, Mani ;
Walther, Thomas ;
Smith, Robert L., II ;
Grayburn, Paul A. .
EUROPEAN HEART JOURNAL, 2017, 38 (09) :634-+
[8]   First-in-Man Experience of a Novel Transcatheter Repair System for Treating Severe Tricuspid Regurgitation [J].
Campelo-Parada, Francisco ;
Perlman, Gidon ;
Philippon, Francois ;
Ye, Jian ;
Thompson, Christopher ;
Bedard, Elisabeth ;
Altisent, Omar Abdul-Jawad ;
Del Trigo, Maria ;
Leipsic, Jonathon ;
Blanke, Philipp ;
Dvir, Danny ;
Puri, Rishi ;
Webb, John G. ;
Rodes-Cabau, Josep .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (22) :2475-2483
[9]   Tricuspid Valve Dysfunction Following Pacemaker or Cardioverter-Defibrillator Implantation [J].
Chang, James D. ;
Manning, Warren J. ;
Ebrille, Elisa ;
Zimetbaum, Peter J. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (18) :2331-2341
[10]   Clinical utility of three-dimensional echocardiography in the evaluation of tricuspid regurgitation induced by implantable device leads [J].
Cheng, Yan ;
Gao, Huanhuan ;
Tang, Liyan ;
Li, Jing ;
Yao, Lei .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2016, 33 (11) :1689-1696