Enhancing real-time cell culture monitoring: Automated Raman model optimization with Taguchi method

被引:3
|
作者
Dong, Xiaoxiao [1 ]
Yan, Xu [1 ,2 ]
Wan, Yuxiang [2 ]
Gao, Dong [2 ]
Jiao, Jingyu [2 ]
Wang, Haibin [2 ]
Qu, Haibin [1 ,3 ]
机构
[1] Zhejiang Univ, Coll Pharmaceut Sci, Pharmaceut Informat Inst, Hangzhou, Peoples R China
[2] Hisun Biopharmaceut Co Ltd, Hangzhou, Peoples R China
[3] Zhejiang Univ, Pharmaceut Informat Inst, Coll Pharmaceut Sci, Hangzhou 310058, Peoples R China
关键词
cell culture; design of experiment; PLS model; Raman spectroscopy; Taguchi analysis; CONCENTRATION PREDICTION; SPECTROSCOPY; SPECTRA; LACTATE;
D O I
10.1002/bit.28688
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Raman spectroscopy has found widespread usage in monitoring cell culture processes both in research and practical applications. However, commonly, preprocessing methods, spectral regions, and modeling parameters have been chosen based on experience or trial-and-error strategies. These choices can significantly impact the performance of the models. There is an urgent need for a simple, effective, and automated approach to determine a suitable procedure for constructing accurate models. This paper introduces the adoption of a design of experiment (DoE) method to optimize partial least squares models for measuring the concentration of different components in cell culture bioreactors. The experimental implementation utilized the orthogonal test table L25(56). Within this framework, five factors were identified as control variables for the DoE method: the window width of Savitzky-Golay smoothing, the baseline correction method, the order of preprocessing steps, spectral regions, and the number of latent variables. The evaluation method for the model was considered as a factor subject to noise. The optimal combination of levels was determined through the signal-to-noise ratio response table employing Taguchi analysis. The effectiveness of this approach was validated through two cases, involving different cultivation scales, different Raman spectrometers, and different analytical components. The results consistently demonstrated that the proposed approach closely approximated the global optimum, regardless of data set size, predictive components, or the brand of Raman spectrometer. The performance of models recommended by the DoE strategy consistently surpassed those built using raw data, underscoring the reliability of models generated through this approach. When compared to exhaustive all-combination experiments, the DoE approach significantly reduces calculation times, making it highly practical for the implementation of Raman spectroscopy in bioprocess monitoring.
引用
收藏
页码:1831 / 1845
页数:15
相关论文
共 50 条
  • [1] Enhancing real-time cell culture process monitoring through the integration of advanced machine learning techniques: A comparative analysis of Raman and capacitance spectroscopies
    Xu, Feng
    Pinto, Nuno
    Zhou, George
    Ahuja, Sanjeev
    BIOTECHNOLOGY PROGRESS, 2025,
  • [2] Generic Raman-based calibration models enabling real-time monitoring of cell culture bioreactors
    Mehdizadeh, Hamidreza
    Lauri, David
    Karry, Krizia M.
    Moshgbar, Mojgan
    Procopio-Melino, Renee
    Drapeau, Denis
    BIOTECHNOLOGY PROGRESS, 2015, 31 (04) : 1004 - 1013
  • [3] OECT MULTIELECTRODE ARRAY FOR REAL-TIME CELL CULTURE MONITORING
    Salyk, Ota
    Vitecek, Jan
    Safarikova, Eva
    Omasta, Lukas
    Stritesy, Stanislav
    Ehlich, Jiri
    Vala, Martin
    Weiter, Martin
    10TH ANNIVERSARY INTERNATIONAL CONFERENCE ON NANOMATERIALS - RESEARCH & APPLICATION (NANOCON 2018 (R)), 2019, : 336 - 341
  • [4] Raman Spectroscopy as a Real-Time In Situ Analyzer for Cell Culture Bioprocesses
    Pitters, Alexander
    Cuellar, Maryann
    Wiegand, Pat
    Gilliam, Sean
    Lewis, Ian R.
    Lenain, Bruno
    NEW BIOTECHNOLOGY, 2016, 33 : S113 - S113
  • [5] Real-time fouling monitoring with Raman spectroscopy
    Virtanen, Tiina
    Reinikainen, Satu-Pia
    Koegler, Martin
    Manttari, Mika
    Viitala, Tapani
    Kallioinen, Mari
    JOURNAL OF MEMBRANE SCIENCE, 2017, 525 : 312 - 319
  • [6] A machine-learning approach to calibrate generic Raman models for real-time monitoring of cell culture processes
    Tulsyan, Aditya
    Schorner, Gregg
    Khodabandehlou, Hamid
    Wan, Tony
    Coufal, Myra
    Undey, Cenk
    BIOTECHNOLOGY AND BIOENGINEERING, 2019, 116 (10) : 2575 - 2586
  • [7] Automatic real-time calibration, assessment, and maintenance of generic Raman models for online monitoring of cell culture processes
    Tulsyan, Aditya
    Wang, Tony
    Schorner, Gregg
    Khodabandehlou, Hamid
    Coufal, Myra
    Undey, Cenk
    BIOTECHNOLOGY AND BIOENGINEERING, 2020, 117 (02) : 406 - 416
  • [8] Morphological cell image analysis for real-time monitoring of stem cell culture
    Mota, Sakina Mohammed
    Rogers, Robert E.
    Haskell, Andrew W.
    McNeill, Eoin P.
    Giger, Maryellen L.
    Kaunas, Roland R.
    Gregory, Carl A.
    Maitland, Kristen C.
    THREE-DIMENSIONAL AND MULTIDIMENSIONAL MICROSCOPY: IMAGE ACQUISITION AND PROCESSING XXVI, 2019, 10883
  • [9] Real-time model correction using Kalman filter for Raman-controlled cell culture processes
    Dong, Xiaoxiao
    He, Zhuohong
    Yan, Xu
    Gao, Dong
    Jiao, Jingyu
    Sun, Yan
    Wang, Haibin
    Qu, Haibin
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2024, 70
  • [10] Real-time model correction using Kalman filter for Raman-controlled cell culture processes
    Dong, Xiaoxiao
    He, Zhuohong
    Yan, Xu
    Gao, Dong
    Jiao, Jingyu
    Sun, Yan
    Wang, Haibin
    Qu, Haibin
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2024, 70 : 251 - 260