Enhancing real-time cell culture monitoring: Automated Raman model optimization with Taguchi method

被引:3
作者
Dong, Xiaoxiao [1 ]
Yan, Xu [1 ,2 ]
Wan, Yuxiang [2 ]
Gao, Dong [2 ]
Jiao, Jingyu [2 ]
Wang, Haibin [2 ]
Qu, Haibin [1 ,3 ]
机构
[1] Zhejiang Univ, Coll Pharmaceut Sci, Pharmaceut Informat Inst, Hangzhou, Peoples R China
[2] Hisun Biopharmaceut Co Ltd, Hangzhou, Peoples R China
[3] Zhejiang Univ, Pharmaceut Informat Inst, Coll Pharmaceut Sci, Hangzhou 310058, Peoples R China
关键词
cell culture; design of experiment; PLS model; Raman spectroscopy; Taguchi analysis; CONCENTRATION PREDICTION; SPECTROSCOPY; SPECTRA; LACTATE;
D O I
10.1002/bit.28688
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Raman spectroscopy has found widespread usage in monitoring cell culture processes both in research and practical applications. However, commonly, preprocessing methods, spectral regions, and modeling parameters have been chosen based on experience or trial-and-error strategies. These choices can significantly impact the performance of the models. There is an urgent need for a simple, effective, and automated approach to determine a suitable procedure for constructing accurate models. This paper introduces the adoption of a design of experiment (DoE) method to optimize partial least squares models for measuring the concentration of different components in cell culture bioreactors. The experimental implementation utilized the orthogonal test table L25(56). Within this framework, five factors were identified as control variables for the DoE method: the window width of Savitzky-Golay smoothing, the baseline correction method, the order of preprocessing steps, spectral regions, and the number of latent variables. The evaluation method for the model was considered as a factor subject to noise. The optimal combination of levels was determined through the signal-to-noise ratio response table employing Taguchi analysis. The effectiveness of this approach was validated through two cases, involving different cultivation scales, different Raman spectrometers, and different analytical components. The results consistently demonstrated that the proposed approach closely approximated the global optimum, regardless of data set size, predictive components, or the brand of Raman spectrometer. The performance of models recommended by the DoE strategy consistently surpassed those built using raw data, underscoring the reliability of models generated through this approach. When compared to exhaustive all-combination experiments, the DoE approach significantly reduces calculation times, making it highly practical for the implementation of Raman spectroscopy in bioprocess monitoring.
引用
收藏
页码:1831 / 1845
页数:15
相关论文
共 39 条
[1]   Raman spectra of biological samples: A study of preprocessing methods [J].
Afseth, Nils Kristian ;
Segtnan, Vegard Herman ;
Wold, Jens Petter .
APPLIED SPECTROSCOPY, 2006, 60 (12) :1358-1367
[2]   Optimization of potassium zinc phosphate anticorrosion pigment by Taguchi experimental design [J].
Alibakhshi, E. ;
Ghasemi, E. ;
Mahdavian, M. .
PROGRESS IN ORGANIC COATINGS, 2013, 76 (01) :224-230
[3]   Developing Global Regression Models for Metabolite Concentration Prediction Regardless of Cell Line [J].
Andre, Silvere ;
Lagresle, Sylvain ;
Da Sliva, Anthony ;
Heimendinger, Pierre ;
Hannas, Zahia ;
Calvosa, Eric ;
Duponchel, Ludovic .
BIOTECHNOLOGY AND BIOENGINEERING, 2017, 114 (11) :2550-2559
[4]   Mammalian cell culture monitoring using in situ spectroscopy: Is your method really optimised? [J].
Andre, Silvere ;
Lagresle, Sylvain ;
Hannas, Zahia ;
Calvosa, Eric ;
Duponchel, Ludovic .
BIOTECHNOLOGY PROGRESS, 2017, 33 (02) :308-316
[5]   Application of wavelet transforms to experimental spectra: Smoothing, denoising, and data set compression [J].
Barclay, VJ ;
Bonner, RF ;
Hamilton, IP .
ANALYTICAL CHEMISTRY, 1997, 69 (01) :78-90
[6]   Cross-Scale Predictive Modeling of CHO Cell Culture Growth and Metabolites Using Raman Spectroscopy and Multivariate Analysis [J].
Berry, Brandon ;
Moretto, Justin ;
Matthews, Thomas ;
Smelko, John ;
Wiltberger, Kelly .
BIOTECHNOLOGY PROGRESS, 2015, 31 (02) :566-577
[7]   In-line monitoring of amino acids in mammalian cell cultures using raman spectroscopy and multivariate chemometrics models [J].
Bhatia, Hemlata ;
Mehdizadeh, Hamidreza ;
Drapeau, Denis ;
Yoon, Seongkyu .
ENGINEERING IN LIFE SCIENCES, 2018, 18 (01) :55-61
[8]   Viable cell density on-line auto-control in perfusion cell culture aided by in-situ Raman spectroscopy [J].
Chen, Gong ;
Hu, Jun ;
Qin, Yongjun ;
Zhou, Weichang .
BIOCHEMICAL ENGINEERING JOURNAL, 2021, 172
[9]   Spectroscopic sensors for in-line bioprocess monitoring in research and pharmaceutical industrial application [J].
Classen, Jens ;
Aupert, Florian ;
Reardon, Kenneth F. ;
Solle, Doerte ;
Scheper, Thomas .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (03) :651-666
[10]   Breaking with trends in pre-processing? [J].
Engel, Jasper ;
Gerretzen, Jan ;
Szymanska, Ewa ;
Jansen, Jeroen J. ;
Downey, Gerard ;
Blanchet, Lionel ;
Buydens, Lutgarde M. C. .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2013, 50 :96-106