Analytical Validation of Two Assays for Equine Ceruloplasmin Ferroxidase Activity Assessment

被引:1
|
作者
Gualandi, Stefano Cecchini [1 ]
Di Palma, Tommaso [1 ]
Boni, Raffaele [1 ]
机构
[1] Univ Basilicata, Dept Sci, Campus Macchia Romana, I-85100 Potenza, Italy
关键词
ammonium iron(II) sulfate; blood plasma; ceruloplasmin; enzyme; horse; o-dianisidine; oxidase activity; ACUTE-PHASE PROTEINS; SERUM CERULOPLASMIN; OXIDATIVE STRESS; OXIDASE ACTIVITY; LIPID-PEROXIDATION; AUTOMATED-ASSAY; BIOMARKERS; PLASMA; COPPER; COWS;
D O I
10.3390/vetsci10100623
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Ceruloplasmin (Cp) assessment in biological samples exploits the oxidase activity of this enzyme against several substrates, such as p-phenylenediamine (p-P), o-dianisidine (o-D) and, most recently, ammonium iron(II) sulfate (AIS). Once developed in humans, these assays are often used in veterinary medicine without appropriately optimizing in the animal species of interest. In this study, two assays using AIS and o-D as substrates have been compared and validated for Cp oxidase activity assessment in horse's plasma. The optimization of the assays was performed mainly by varying the buffer pH as well as the buffer and the substrate molar concentration. Under the best analytical conditions obtained, the horse blood serum samples were treated with sodium azide, a potent Cp inhibitor. In the o-D assay, 500 mu M sodium azide treatment completely inhibits the enzymatic activity of Cp, whereas, using the AIS assay, a residual analytical signal was still present even at the highest (2000 mu M) sodium azide concentration. Even though the analytical values obtained from these methods are well correlated, the enzymatic activity values significantly differ when expressed in Units L-1. A disagreement between these assays has also been detected with the Bland-Altman plot, showing a progressive discrepancy between methods with increasing analytical values.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Validation of PON1 enzyme activity assays for longitudinal studies
    Huen, Karen
    Richter, Rebecca
    Furlong, Clement
    Eskenazi, Brenda
    Holland, Nina
    CLINICA CHIMICA ACTA, 2009, 402 (1-2) : 67 - 74
  • [42] Automated assays for trace elements and ferritin measurement in saliva of pigs: Analytical validation and a pilot application to evaluate different iron status
    Ortin-Bustillo, A.
    Vidal, G. Ramis
    Tortosa, D. Escribano
    Lopez-Arjona, M.
    Rubio, C. Peres
    Ceron, J. J.
    Munoz-Prieto, A.
    Pardo-Marin, L.
    Lopez-Martinez, M. J.
    Botia, M.
    Martinez-Subiela, S.
    Tvarijonaviciute, A.
    Tecles, F.
    RESEARCH IN VETERINARY SCIENCE, 2022, 152 : 410 - 416
  • [43] Validation of a commercially available photometric analytical system for assessment of plasma oxidative status in healthy horses
    Vaughn, Sarah A.
    Norton, Natalie A.
    Hurley, David J.
    Hart, Kelsey A.
    VETERINARY IMMUNOLOGY AND IMMUNOPATHOLOGY, 2023, 265
  • [44] Evaluation of a chronic exposure to nanoplastics in goldfish (Carassius auratus): Analytical validation of automated assays for the measurement of
    Blonc, M.
    Brandts, I.
    Canovas, M.
    Franco-Martinez, L.
    Rubio, C. P.
    Tort, L.
    Tvarijonaviciute, A.
    Gravato, C.
    Teles, M.
    ECOLOGICAL INDICATORS, 2023, 147
  • [45] Assessment of copper status in epileptic patients treated with anticonvulsant drugs by measuring the specific oxidase activity of ceruloplasmin
    Tutor-Crespo, MJ
    Hermida, J
    Tutor, JC
    EPILEPSY RESEARCH, 2003, 56 (2-3) : 147 - 153
  • [46] Development and Preliminary Validation of an Equine Brief Pain Inventory for Owner Assessment of Chronic Pain Due to Osteoarthritis in Horses
    Howard, Diane L.
    Lancaster, Bryony
    de Grauw, Janny
    ANIMALS, 2024, 14 (02):
  • [47] Generic Protocols for the Analytical Validation of Next-Generation Sequencing-Based ctDNA Assays: A Joint Consensus Recommendation of the BloodPAC's Analytical Variables Working Group
    Godsey, James H.
    Silvestro, Angela
    Barrett, J. Carl
    Bramlett, Kelli
    Chudova, Darya
    Deras, Ina
    Dickey, Jennifer
    Hicks, James
    Johann, Donald J.
    Leary, Rebecca
    Lee, Jerry S. H.
    McMullen, Joe
    McShane, Lisa
    Nakamura, Katherine
    Richardson, Aaron O.
    Ryder, Matthew
    Simmons, John
    Tanzella, Kelli
    Yee, Laura
    Leiman, Lauren C.
    CLINICAL CHEMISTRY, 2020, 66 (09) : 1156 - 1166
  • [48] Dataset of Partial Analytical Validation of the 1,2-O-Dilauryl-Rac-Glycero-3-Glutaric Acid-(6′-Methylresorufin) Ester (DGGR) Lipase Assay in Equine Plasma
    Peters, Laureen Michele
    Howard, Judith
    DATA, 2023, 8 (03)
  • [49] Serum paraoxonase 1 activity in cats: analytical validation, reference intervals, and correlation with serum amyloid A and alpha-1-acid glycoprotein
    Rossi, Gabriele
    Meazzi, Sara
    Giordano, Alessia
    Paltrinieri, Saverio
    JOURNAL OF VETERINARY DIAGNOSTIC INVESTIGATION, 2020, 32 (06) : 844 - 855
  • [50] Development, validation and greenness assessment of environmentally friendly analytical methods for the quantification of lenalidomide in pharmaceutical formulations
    Demir, Ibrahim
    Bulduk, Ibrahim
    Enginar, Huseyin
    ACTA CHROMATOGRAPHICA, 2024, 36 (04) : 395 - 405