Analytical Validation of Two Assays for Equine Ceruloplasmin Ferroxidase Activity Assessment

被引:1
|
作者
Gualandi, Stefano Cecchini [1 ]
Di Palma, Tommaso [1 ]
Boni, Raffaele [1 ]
机构
[1] Univ Basilicata, Dept Sci, Campus Macchia Romana, I-85100 Potenza, Italy
关键词
ammonium iron(II) sulfate; blood plasma; ceruloplasmin; enzyme; horse; o-dianisidine; oxidase activity; ACUTE-PHASE PROTEINS; SERUM CERULOPLASMIN; OXIDATIVE STRESS; OXIDASE ACTIVITY; LIPID-PEROXIDATION; AUTOMATED-ASSAY; BIOMARKERS; PLASMA; COPPER; COWS;
D O I
10.3390/vetsci10100623
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Ceruloplasmin (Cp) assessment in biological samples exploits the oxidase activity of this enzyme against several substrates, such as p-phenylenediamine (p-P), o-dianisidine (o-D) and, most recently, ammonium iron(II) sulfate (AIS). Once developed in humans, these assays are often used in veterinary medicine without appropriately optimizing in the animal species of interest. In this study, two assays using AIS and o-D as substrates have been compared and validated for Cp oxidase activity assessment in horse's plasma. The optimization of the assays was performed mainly by varying the buffer pH as well as the buffer and the substrate molar concentration. Under the best analytical conditions obtained, the horse blood serum samples were treated with sodium azide, a potent Cp inhibitor. In the o-D assay, 500 mu M sodium azide treatment completely inhibits the enzymatic activity of Cp, whereas, using the AIS assay, a residual analytical signal was still present even at the highest (2000 mu M) sodium azide concentration. Even though the analytical values obtained from these methods are well correlated, the enzymatic activity values significantly differ when expressed in Units L-1. A disagreement between these assays has also been detected with the Bland-Altman plot, showing a progressive discrepancy between methods with increasing analytical values.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Low Serum Ferroxidase I Activity Is Associated With Mortality in Heart Failure and Related to Both Peroxynitrite-Induced Cysteine Oxidation and Tyrosine Nitration of Ceruloplasmin
    Cabassi, Aderville
    Binno, Simone Maurizio
    Tedeschi, Stefano
    Ruzicka, Valerie
    Dancelli, Simona
    Rocco, Rossana
    Vicini, Vanni
    Coghi, Pietro
    Regolisti, Giuseppe
    Montanari, Alberto
    Fiaccadori, Enrico
    Govoni, Paolo
    Piepoli, Massimo
    de Champlain, Jacques
    CIRCULATION RESEARCH, 2014, 114 (11) : 1723 - +
  • [32] Serum ceruloplasmin and ferroxidase activity are decreased in HFE C282Y homozygote male iron-overloaded patients
    Lainé, F
    Ropert, M
    Le Lan, C
    Loréal, O
    Bellissant, E
    Jard, C
    Pouchard, M
    Le Treut, A
    Brissot, P
    JOURNAL OF HEPATOLOGY, 2002, 36 (01) : 60 - 65
  • [33] Functional link between ferroxidase activity of ceruloplasmin and protective effect of apo-lactoferrin: studying rats kept on a silver chloride diet
    Kostevich, Valeria A.
    Sokolov, Alexey V.
    Kozlov, Stanislav O.
    Vlasenko, Anna Yu.
    Kolmakov, Nikolay N.
    Zakharova, Elena T.
    Vasilyev, Vadim B.
    BIOMETALS, 2016, 29 (04) : 691 - 704
  • [34] Functional link between ferroxidase activity of ceruloplasmin and protective effect of apo-lactoferrin: studying rats kept on a silver chloride diet
    Valeria A. Kostevich
    Alexey V. Sokolov
    Stanislav O. Kozlov
    Anna Yu. Vlasenko
    Nikolay N. Kolmakov
    Elena T. Zakharova
    Vadim B. Vasilyev
    BioMetals, 2016, 29 : 691 - 704
  • [35] Validation of quantitative polymerase chain reaction assays for measuring cytokine expression in equine macrophages
    Allen, Charlotte A.
    Payne, Susan L.
    Harville, Melissa
    Cohen, Noah
    Russell, Karen E.
    JOURNAL OF IMMUNOLOGICAL METHODS, 2007, 328 (1-2) : 59 - 69
  • [36] Validation of the CellRox Deep Red® fluorescent probe to oxidative stress assessment in equine spermatozoa
    Lanconi, Renata
    de Arruda, Rubens Paes
    Rodrigues Alves, Maira Bianchi
    Oliveira, Leticia Zoccolaro
    dos Santos, Gabriel De Carli
    Lemes, Kleber Menegon
    Florez-Rodriguez, Shirley Andrea
    Carvalho Celeghini, Eneiva Carla
    ANIMAL REPRODUCTION, 2017, 14 (02) : 437 - 441
  • [37] Validation and comparison of two methods of measuring lactate in equine plasma
    Butudom, P.
    Foreman, J. H.
    Kline, K. H.
    Whittem, E. L.
    EQUINE VETERINARY JOURNAL, 2010, 42 : 155 - 160
  • [38] Assessment of copper status in pregnancy by means of determining the specific oxidase activity of ceruloplasmin
    Louro, MO
    Cocho, JA
    Tutor, JC
    CLINICA CHIMICA ACTA, 2001, 312 (1-2) : 123 - 127
  • [39] Analytical Validation of Cxbladder® Detect, Triage, and Monitor: Assays for Detection and Management of Urothelial Carcinoma
    Harvey, Justin C.
    Cambridge, Lisa M.
    Ellen, Charles W.
    Colonval, Megan
    Hazlett, Jody A.
    Newell, Jordan
    Zhou, Xin
    Guilford, Parry J.
    DIAGNOSTICS, 2024, 14 (18)
  • [40] Analytical validation of bovine plasma ceruloplasmin measurement by p-phenylenediamine oxidation and effect of storage time and freezing temperature
    Hussein Awad Hussein
    Rudolf Staufenbiel
    Acta Veterinaria Scandinavica, 59