Design, optimization, and evaluation of a wet electrostatic precipitator (ESP) for aerosol collection

被引:9
|
作者
Badami, Mohammad Mahdi [1 ]
Tohidi, Ramin [1 ]
Aldekheel, Mohammad [1 ,2 ]
Farahani, Vahid Jalali [1 ]
Verma, Vishal [3 ]
Sioutas, Constantinos [1 ,4 ]
机构
[1] Univ Southern Calif, Dept Civil & Environm Engn, Los Angeles, CA 90089 USA
[2] Kuwait Univ, Dept Civil Engn, POB 5969, Safat 13060, Kuwait
[3] Univ Illinois, Dept Civil & Environm Engn, Urbana, IL 61801 USA
[4] Univ Southern Calif, Civil & Environm Engn, 3620 S Vermont Ave KAP210, Los Angeles, CA 90089 USA
基金
美国国家卫生研究院;
关键词
Wet electrostatic precipitator; Particulate matter; Particle concentrators; Total organic carbon; Corona discharge; DTT; ENRICHMENT SYSTEM VACES; POLYCYCLIC AROMATIC-HYDROCARBONS; COARSE AMBIENT PARTICLES; PARTICULATE MATTER PM; SIMULTANEOUS IN-VIVO; OZONE GENERATION; REACTIVE OXYGEN; SOURCE APPORTIONMENT; SAMPLING ARTIFACTS; SEMIVOLATILE AEROSOLS;
D O I
10.1016/j.atmosenv.2023.119858
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study, we developed, optimized, and evaluated in lab and field experiments a wet electrostatic precipitator (ESP) for the collection of ambient PM2.5 (particulate matter with aerodynamic diameter <2.5 & mu;m) into ultrapure water by applying an electrostatic charge to the particles. We operated the wet ESP at different flow rates and voltages to identify the optimal operating conditions. According to our experimental measurements, a flow rate of 125 lpm and an applied positive voltage of 11 kV resulted in a lower ozone generation of 133 ppb and a particle collection efficiency exceeding 80-90% in all size ranges. For the field tests, the wet ESP was compared with the versatile aerosol concentration enrichment system (VACES) connected to a BioSampler, a PTFE filter sampler, and an OC/EC analyzer (Sunset Laboratory Inc., USA) as a reference. The chemical analysis results indicated the wet ESP concentrations of metal and trace elements were in very good agreement with those measured by the VACES/BioSampler and PTFE filter sampler. Moreover, our results showed comparable total organic carbon (TOC) concentrations measured by the wet ESP, BioSampler, and OC/EC analyzer, while somewhat lower TOC concentrations were measured by the PTFE filter sampler, possibly due to the limitations of extracting water-insoluble organic carbon (WIOC) from a dry substrate in the latter sampler. The comparable TOC content in the wet ESP and BioSampler samples differs from previous findings that showed higher TOC content in BioSampler samples compared to those collected by dry ESP. The results of the Dithiothreitol (DTT) assay showed comparable DTT activity in the VACES/BioSampler and wet ESP PM samples while slightly lower in the PTFE filter samples. Overall, our results suggest that the wet ESP could be a promising alternative to other conventional sampling methods.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] An efficient thumbtack-cylinder type wet electrostatic precipitator for moxa smoke aerosol control
    Yu, Zhenhui
    Liu, Jingxian
    Shen, Ruiqing
    Li, Guodong
    Lv, Chao
    Zhu, Mian
    POWDER TECHNOLOGY, 2023, 424
  • [32] Exploring the role of sulfuric acid aerosol in corona discharge through a honeycomb wet electrostatic precipitator
    Wang, Yifan
    Gao, Wenchao
    Zhang, Xuefeng
    Zhang, Hao
    Liu, Wenju
    Chen, Yaoji
    Shao, Lingyu
    Wu, Zhicheng
    Dai, Haobo
    Zheng, Chenghang
    Gao, Xiang
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2021, 146 : 763 - 769
  • [33] Performance of a Wet Electrostatic Precipitator in Marine Applications
    Jarvinen, Anssi
    Lehtoranta, Kati
    Aakko-Saksa, Paeivi
    Karppanen, Mikko
    Murtonen, Timo
    Martikainen, Jarno
    Kuusisto, Jarmo
    Nyyssonen, Sami
    Koponen, Paivi
    Piimakorpi, Pekka
    Friman, Eero
    Orasuo, Varpu
    Rintanen, Jaakko
    Jokiluoma, Juha
    Kuittinen, Niina
    Ronkko, Topi
    JOURNAL OF MARINE SCIENCE AND ENGINEERING, 2023, 11 (02)
  • [34] A CLOSER LOOK AT ELECTROSTATIC PRECIPITATOR WET BOTTOMS
    BALASIC, PJ
    PEACOS, MM
    TAPPI, 1980, 63 (06): : 41 - 43
  • [35] Study on Promoting Coal-fired Dust Collection by Chemical Coagulation in Wet Electrostatic Precipitator
    Zhai X.
    Xiao L.
    Han Y.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2023, 43 (02): : 651 - 658
  • [36] Electrostatic dust collection in the gas inlet and outlet of an electrostatic precipitator
    Eigenwillig, S
    GEFAHRSTOFFE REINHALTUNG DER LUFT, 1996, 56 (01): : 23 - 25
  • [37] Collection of airborne microorganisms by a new electrostatic precipitator
    Mainelis, G. (mainelis@envsci.rutgers.edu), 1600, Elsevier Ltd (33):
  • [38] COLLECTION OF IRON OXIDE FUMES WITH AN ELECTROSTATIC PRECIPITATOR
    SMITH, WM
    COY, DW
    BLAST FURNACE AND STEEL PLANT, 1966, 54 (09): : 830 - &
  • [39] Collection of airborne microorganisms by a new electrostatic precipitator
    Mainelis, G
    Adhikari, A
    Willeke, K
    Lee, SA
    Reponen, T
    Grinshpun, SA
    JOURNAL OF AEROSOL SCIENCE, 2002, 33 (10) : 1417 - 1432
  • [40] UNSTEADY MODELING OF POWDERED ACTIVATED CARBON DEPOSITION ON COLLECTION ELECTRODE OF A LAB-SCALE ELECTROSTATIC PRECIPITATOR (ESP)
    Khakpour, Yasmin
    Clack, Herek L.
    PROCEEDINGS OF THE ASME FLUIDS ENGINEERING DIVISION SUMMER MEETING, 2012, VOL 1, PTS A AND B, SYMPOSIA, 2012, : 307 - 313