Intraocular Lens Exchange: Indications, Comparative Outcomes by Technique, and

被引:2
作者
Patel, Veshesh [1 ]
Pakravan, Parastou [1 ]
Lai, James [1 ]
Watane, Arjun [1 ,2 ]
Mehra, Divy [1 ]
Eatz, Tiffany Alyssa [1 ]
Patel, Nimesh [1 ,3 ]
Yannuzzi, Nicolas A. [1 ]
Sridhar, Jayanth [1 ]
机构
[1] Univ Miami, Miller Sch Med, Bascom Palmer Eye Inst, 900 NW 17th St, Miami, FL 33136 USA
[2] Yale Sch Med, Dept Ophthalmol & Visual Sci, New Haven, CT USA
[3] Harvard Med Sch, Mass Eye & Ear, Boston, MA USA
来源
CLINICAL OPHTHALMOLOGY | 2023年 / 17卷
关键词
intraocular lens; dislocation; Yamane; techniques; cataracts; complications; CATARACT-SURGERY; COUNTING FINGERS; HAND MOTION; COMPLICATIONS; CHAMBER; DISLOCATION; SECONDARY;
D O I
10.2147/OPTH.S399857
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To describe the indications, outcomes, and complications associated with intraocular lens (IOL) exchange.Patients and Methods: To determine the relative frequency of postoperative complications between techniques for all patients undergoing IOL exchange from May 1, 2014 through August 31, 2020.Results: IOL exchange was performed in 511 eyes of 489 patients (59.7% men; mean age: 67.0 +/- 13.9 years, median time from cataract procedure to IOL exchange: 47.5 months). Mean uncorrected visual acuity significantly improved from 20/192 Snellen equivalent (logMAR 0.981) preoperatively to 20/61 (logMAR 0.487) at last follow-up (P < 0.001). Overall, 384 eyes (78.7%) met their desired refractive outcome within +/- 1.0 diopter (D). The most frequent complication was cystoid macular edema (CME) (n=39, 7.6%). Iris-sutured technique was associated with significantly greater frequency of subsequent IOL dislocation (10.3%) than 4-point scleral sutured (0%, P = 0.002), anterior chamber IOL (ACIOL, 1.5%, P = 0.01), and 2-point scleral sutured (0%, P = 0.03) techniques. Yamane scleral-fixation technique was associated with significantly greater frequency of developing IOL tilt (11.8%) than ACIOL (0%, P = 0.002), 4-point scleral sutured (1.1%, P = 0.01), 2-point scleral sutured (0%, P = 0.04), and iris-sutured (0%, P = 0.04) techniques.Conclusion: IOL exchange significantly improved uncorrected visual acuity and more than three-quarters of eyes met the refractive goal. Certain techniques were associated with complications, including subsequent dislocation associated with iris-sutured technique and IOL tilt associated with Yamane scleral-fixation technique. This information may help guide surgeons in deciding between procedural techniques for individual patients during IOL exchange preoperative planning.
引用
收藏
页码:941 / 951
页数:11
相关论文
共 50 条
  • [41] Comparison of Safety and Efficacy of Four-Point Scleral Intraocular Lens Fixation and the Yamane Technique
    Blagun, Natalia
    Krix-Jachym, Karolina
    Rekas, Marek
    OPHTHALMOLOGY AND THERAPY, 2024, 13 (07) : 1955 - 1966
  • [42] Refractive errors after sutureless intrascleral fixation of intraocular lens
    Kakisu, Masato
    Baba, Takayuki
    Tatsumi, Tomoaki
    Iwase, Takehito
    Nizawa, Tomohiro
    Miura, Gen
    Yamamoto, Shuichi
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2021, 259 (10) : 3003 - 3009
  • [43] Indications, Complications, and Early Postoperative Course of Recovery of Intraocular Lens Exchange Surgery: a Single-Center Retrospective Study
    Silva, Marcio
    Orguel, Selim
    Becker, Matthias
    Freiberg, Florentina Joyce
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2023, 240 (04) : 415 - 420
  • [44] Comparative evaluation of visual outcomes after bilateral implantation of an advanced or conventional monofocal intraocular lens
    Lopes, Diogo
    Loureiro, Tomas
    Carreira, Rita
    Rodrigues Barros, Sandra
    Cardoso, Joao Nobre
    Campos, Paul
    Machado, Ines
    Campos, Nuno
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (01) : 229 - 234
  • [45] Incidence of Intraocular Lens Exchange after Cataract Surgery
    Elsayed, Maram E. A. Abdalla
    Ahmad, Khabir
    Al-Abdullah, Abdulelah A.
    Malik, Rizwan
    Khandekar, Rajiv
    Martinez-Osorio, Hernan
    Mura, Marco
    Schatz, Patrik
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [46] One Year Outcomes and Stability of a Novel Scleral Anchored Intraocular Lens
    Abed, Edoardo
    Forlini, Matteo
    Bendo, Edlira
    Imburgia, Aurelio
    Mularoni, Alessandro
    Gizzi, Corrado
    Santino, Giuseppe
    Corazza, Daniele
    Costa, Giacomo
    JOURNAL OF OPHTHALMOLOGY, 2021, 2021
  • [47] Secondary intraocular lens interventions: predisposing factors, indications and coincident procedures
    Lichtinger, Alejandro
    Kim, Peter
    Yeung, Sonia N.
    Amiran, Maoz D.
    Alangh, Manreet
    Rootman, David S.
    INTERNATIONAL OPHTHALMOLOGY, 2013, 33 (02) : 111 - 115
  • [48] Outcomes of secondary intraocular lens implantation in the Infant Aphakia Treatment Study
    VanderVeen, Deborah K.
    Drews-Botsch, Carolyn D.
    Nizam, Azhar
    Bothun, Erick D.
    Wilson, Lorri B.
    Wilson, M. Edward
    Lambert, Scott R.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (02) : 172 - 177
  • [49] A comparative study of the visual outcomes between a new trifocal and an extended depth of focus intraocular lens
    Ruiz-Mesa, Ramon
    Abengozar-Vela, Antonio
    Ruiz-Santos, Maria
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2018, 28 (02) : 182 - 187
  • [50] Secondary intraocular lens interventions: predisposing factors, indications and coincident procedures
    Alejandro Lichtinger
    Peter Kim
    Sonia N. Yeung
    Maoz D. Amiran
    Manreet Alangh
    David S. Rootman
    International Ophthalmology, 2013, 33 : 111 - 115