共 50 条
Intraocular Lens Exchange: Indications, Comparative Outcomes by Technique, and
被引:2
作者:
Patel, Veshesh
[1
]
Pakravan, Parastou
[1
]
Lai, James
[1
]
Watane, Arjun
[1
,2
]
Mehra, Divy
[1
]
Eatz, Tiffany Alyssa
[1
]
Patel, Nimesh
[1
,3
]
Yannuzzi, Nicolas A.
[1
]
Sridhar, Jayanth
[1
]
机构:
[1] Univ Miami, Miller Sch Med, Bascom Palmer Eye Inst, 900 NW 17th St, Miami, FL 33136 USA
[2] Yale Sch Med, Dept Ophthalmol & Visual Sci, New Haven, CT USA
[3] Harvard Med Sch, Mass Eye & Ear, Boston, MA USA
来源:
CLINICAL OPHTHALMOLOGY
|
2023年
/
17卷
关键词:
intraocular lens;
dislocation;
Yamane;
techniques;
cataracts;
complications;
CATARACT-SURGERY;
COUNTING FINGERS;
HAND MOTION;
COMPLICATIONS;
CHAMBER;
DISLOCATION;
SECONDARY;
D O I:
10.2147/OPTH.S399857
中图分类号:
R77 [眼科学];
学科分类号:
100212 ;
摘要:
Purpose: To describe the indications, outcomes, and complications associated with intraocular lens (IOL) exchange.Patients and Methods: To determine the relative frequency of postoperative complications between techniques for all patients undergoing IOL exchange from May 1, 2014 through August 31, 2020.Results: IOL exchange was performed in 511 eyes of 489 patients (59.7% men; mean age: 67.0 +/- 13.9 years, median time from cataract procedure to IOL exchange: 47.5 months). Mean uncorrected visual acuity significantly improved from 20/192 Snellen equivalent (logMAR 0.981) preoperatively to 20/61 (logMAR 0.487) at last follow-up (P < 0.001). Overall, 384 eyes (78.7%) met their desired refractive outcome within +/- 1.0 diopter (D). The most frequent complication was cystoid macular edema (CME) (n=39, 7.6%). Iris-sutured technique was associated with significantly greater frequency of subsequent IOL dislocation (10.3%) than 4-point scleral sutured (0%, P = 0.002), anterior chamber IOL (ACIOL, 1.5%, P = 0.01), and 2-point scleral sutured (0%, P = 0.03) techniques. Yamane scleral-fixation technique was associated with significantly greater frequency of developing IOL tilt (11.8%) than ACIOL (0%, P = 0.002), 4-point scleral sutured (1.1%, P = 0.01), 2-point scleral sutured (0%, P = 0.04), and iris-sutured (0%, P = 0.04) techniques.Conclusion: IOL exchange significantly improved uncorrected visual acuity and more than three-quarters of eyes met the refractive goal. Certain techniques were associated with complications, including subsequent dislocation associated with iris-sutured technique and IOL tilt associated with Yamane scleral-fixation technique. This information may help guide surgeons in deciding between procedural techniques for individual patients during IOL exchange preoperative planning.
引用
收藏
页码:941 / 951
页数:11
相关论文