Value of dual-source CT dual-energy parameters combined with serum detection of VEGF and CEA in the diagnosis of early lung cancer

被引:3
作者
Ren, Liliang [1 ]
Yang, Yulong [2 ]
机构
[1] Yantai Mt Hosp, Imaging Dept, Yantai, Shandong, Peoples R China
[2] Hebei Yanda Hosp, Dept Resp & Crit Care Med, West Side Sibolan West Rd, Langfang 065200, Hebei, Peoples R China
关键词
Dual-source CT; dual-energy; VEGF; CEA; lung cancer; CYFRA21-1; NSE;
D O I
10.1080/02648725.2023.2166708
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
To discuss the value of dual-source CT dual-energy parameters combined with serum detection of vascular endothelial growth factor (VEGF) and carcinoembryonic antigen (CEA) in the diagnosis of early lung cancer (LC). In total, 100 patients with lung lesions in our hospital from January 2020 to January 2022 were selected for retrospective study, and were divided into the lung cancer group (group A) and benign lung disease group (group B) according to the final results of pathological diagnosis, using dual-source CT dual-energy scanning combined with serum detection of VEGF and CEA to analyze the diagnostic values of single detection and combined detection. Among the 100 patients with lung lesions, there were 58 patients with LC and 42 patients with benign lung diseases after pathological examination, with no statistical difference in normalized iodine concentration (NIC) and the increased value of iodine at arterial phase between the two groups (P > 0.05). The NIC value of group A was higher than group B at venous phase (P < 0.05). The serum levels of VEGF and CEA in group A were higher than group B (P < 0.05). The area under the curve, specificity, sensitivity, Youden index and 95% CI of combined diagnosis were higher than single detection of NIC, VEGF and CEA at venous phase. The combined application of dual-source CT dual-energy parameters and serum detection of VEGF and CEA has higher diagnostic value in patients with early LC, which can provide effective reference for clinical diagnosis and treatment, with higher application value in clinic.
引用
收藏
页码:1000 / 1011
页数:12
相关论文
共 50 条
  • [41] The Relationship between Quantitative Parameters of Dual-energy CT and HIF-1α Expression in Non-Small Cell Lung Cancer
    Meng, Xi-Wen
    Pi, Ya-Wen
    Wang, Guang-Li
    Qi, Shu-Na
    Zhang, Gui-Hui
    Cheng, Yu-Xia
    CURRENT MEDICAL IMAGING, 2024, 20
  • [42] Quantitative evaluation of iodine and fat using dual-energy CT for assessments of the tumor aggressiveness in lung cancer
    Mariko Doai
    Naoko Tsuchiya
    Yuka Nishino
    Hisao Tonami
    Katsuo Usuda
    Hidetaka Uramoto
    Munetaka Matoba
    Hiroji Nagata
    Egyptian Journal of Radiology and Nuclear Medicine, 53
  • [43] Quantitative evaluation of iodine and fat using dual-energy CT for assessments of the tumor aggressiveness in lung cancer
    Doai, Mariko
    Tsuchiya, Naoko
    Nishino, Yuka
    Tonami, Hisao
    Usuda, Katsuo
    Uramoto, Hidetaka
    Matoba, Munetaka
    Nagata, Hiroji
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2022, 53 (01)
  • [44] Clinical application of dual-source CT in the evaluation of patients with lung cancer: correlation with perfusion scintigraphy and pulmonary function tests
    Fraioli, F.
    Serra, G.
    Liberali, S.
    Fiorelli, A.
    Liparulo, V.
    Zaccagna, F.
    Ciccariello, G.
    Catalano, C.
    Passariello, R.
    RADIOLOGIA MEDICA, 2011, 116 (06): : 842 - 857
  • [45] Diagnostic accuracy of coronary CT angiography combined with dual-energy myocardial perfusion imaging for detection of myocardial infarction
    Han, Ruijuan
    Sun, Kai
    Lu, Bin
    Zhao, Ruiping
    Li, Kuncheng
    Yang, Xinchun
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2017, 14 (01) : 207 - 213
  • [46] Myeloma bone disease imaging on a 1st-generation clinical photon-counting detector CT vs. 2nd-generation dual-source dual-energy CT
    Winkelmann, Moritz T.
    Hagen, Florian
    Le-Yannou, Lucie
    Weiss, Jakob
    Riffel, Philipp
    Gutjahr, Ralf
    Faby, Sebastian
    Nikolaou, Konstantin
    Horger, Marius
    EUROPEAN RADIOLOGY, 2023, 33 (04) : 2415 - 2425
  • [47] Myeloma bone disease imaging on a 1st-generation clinical photon-counting detector CT vs. 2nd-generation dual-source dual-energy CT
    Moritz T. Winkelmann
    Florian Hagen
    Lucie Le-Yannou
    Jakob Weiss
    Philipp Riffel
    Ralf Gutjahr
    Sebastian Faby
    Konstantin Nikolaou
    Marius Horger
    European Radiology, 2023, 33 : 2415 - 2425
  • [48] Dual-energy snap-shot perfusion CT in suspect pulmonary nodules and masses and for lung cancer staging
    Sudarski, Sonja
    Hagelstein, Claudia
    Weis, Meike
    Schoenberg, Stefan O.
    Apfaltrer, Paul
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (12) : 2393 - 2400
  • [49] Dual-Energy Computed Tomography for the Diagnosis of Mediastinal Lymph Node Metastasis in Lung Cancer Patients: A Preliminary Study
    Hu, Xiaoli
    Gu, Qianbiao
    Zhang, Kun
    Deng, Dong
    Li, Lei
    Li, Ping
    Shen, Hongrong
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2021, 45 (03) : 490 - 494
  • [50] Cancer Patient–Derived Circulating Microparticles Enhance Lung Metastasis in a Rat Model: Dual-Source CT, Cellular, and Molecular Studies
    Sheung-Fat Ko
    Hon-Kan Yip
    Yen-Yi Zhen
    Chia-Chang Lee
    Jung-Hui Li
    Chen-Chang Lee
    Steve Leu
    Chung-Cheng Huang
    Shu-Hang Ng
    Jui-Wei Lin
    Molecular Imaging and Biology, 2016, 18 : 490 - 499