Value of dual-source CT dual-energy parameters combined with serum detection of VEGF and CEA in the diagnosis of early lung cancer

被引:3
作者
Ren, Liliang [1 ]
Yang, Yulong [2 ]
机构
[1] Yantai Mt Hosp, Imaging Dept, Yantai, Shandong, Peoples R China
[2] Hebei Yanda Hosp, Dept Resp & Crit Care Med, West Side Sibolan West Rd, Langfang 065200, Hebei, Peoples R China
关键词
Dual-source CT; dual-energy; VEGF; CEA; lung cancer; CYFRA21-1; NSE;
D O I
10.1080/02648725.2023.2166708
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
To discuss the value of dual-source CT dual-energy parameters combined with serum detection of vascular endothelial growth factor (VEGF) and carcinoembryonic antigen (CEA) in the diagnosis of early lung cancer (LC). In total, 100 patients with lung lesions in our hospital from January 2020 to January 2022 were selected for retrospective study, and were divided into the lung cancer group (group A) and benign lung disease group (group B) according to the final results of pathological diagnosis, using dual-source CT dual-energy scanning combined with serum detection of VEGF and CEA to analyze the diagnostic values of single detection and combined detection. Among the 100 patients with lung lesions, there were 58 patients with LC and 42 patients with benign lung diseases after pathological examination, with no statistical difference in normalized iodine concentration (NIC) and the increased value of iodine at arterial phase between the two groups (P > 0.05). The NIC value of group A was higher than group B at venous phase (P < 0.05). The serum levels of VEGF and CEA in group A were higher than group B (P < 0.05). The area under the curve, specificity, sensitivity, Youden index and 95% CI of combined diagnosis were higher than single detection of NIC, VEGF and CEA at venous phase. The combined application of dual-source CT dual-energy parameters and serum detection of VEGF and CEA has higher diagnostic value in patients with early LC, which can provide effective reference for clinical diagnosis and treatment, with higher application value in clinic.
引用
收藏
页码:1000 / 1011
页数:12
相关论文
共 50 条
  • [31] Optimization of head and neck vascular CT angiography using variable rate bolus tracking technique and third-generation dual-source CT dual-energy scanning
    Lin, Wei-Hua
    Zhang, Fei-Peng
    Wang, Bing-Quan
    Huang, Rui-Gang
    Zhan, A-Lai
    Xiao, Hui-Jun
    BMC MEDICAL IMAGING, 2025, 25 (01):
  • [32] The Application of Iodine Quantitative Information Obtained by Dual-Source Dual-Energy Computed Tomography on Chemoradiotherapy Effect Monitoring for Cervical Cancer: A Preliminary Study
    Jiang, Changqin
    Yang, Pin
    Lei, Junqiang
    Li, Jinkui
    Yan, Kun
    Li, Feilong
    Yan, Ruifeng
    Xia, Lichao
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2017, 41 (05) : 737 - 745
  • [33] Method for determining the half-value layer in computed tomography scans using a real-time dosimeter: Application to dual-source dual-energy acquisition
    Matsubara, Kosuke
    Nagata, Hiroji
    Okubo, Rena
    Takata, Tadanori
    Kobayashi, Masanao
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 44 : 227 - 231
  • [34] Determining the Optimal Energy Level of Virtual Monoenergetic Images in Dual-Source CT for Diagnosis of Bowel Obstruction and Colitis
    Lahuna, Loris
    Greffier, Joel
    Goupil, Jean
    Frandon, Julien
    Pastor, Maxime
    De Oliveira, Fabien
    Beregi, Jean Paul
    Dabli, Djamel
    DIAGNOSTICS, 2023, 13 (23)
  • [35] Dual-Energy CT Perfusion During Pharmacologic Stress for the Assessment of Myocardial Perfusion Defects Using a Second-Generation Dual-Source CT: A Comparison With Cardiac Magnetic Resonance Imaging
    Kim, Sung Mok
    Chang, Sung-A
    Shin, Wonseon
    Choe, Yeon Hyeon
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2014, 38 (01) : 44 - 52
  • [36] Single-source Dual-energy CT as a Part of 18F-FDG PET/CT: Direct Comparison of Iodine-related and Metabolic Parameters in Non-small Cell Lung Cancer
    Baxa, Jan
    Matouskova, Tana
    Ludvik, Jaroslav
    Sedlmair, Martin
    Flohr, Thomas
    Schmidt, Bernhard
    Bejcek, Jiri
    Pesek, Milos
    Ferda, Jiri
    ANTICANCER RESEARCH, 2018, 38 (07) : 4131 - 4137
  • [37] Objective and Subjective Image Quality of Liver Prechyma and Hepatic Metastass with Virtual Monoenergetic Dual-source Dual-energy CT Reconstructions: An Analysis in Patients with Gastrointestinal Stromal Tumor
    Sudarski, Sonja
    Apfaltrer, Paul
    Nance, John W., Jr.
    Meyer, Mathias
    Fink, Christian
    Hohenberger, Peter
    Leidecker, Christianne
    Schoenberg, Stefan O.
    Henzler, Thomas
    ACADEMIC RADIOLOGY, 2014, 21 (04) : 514 - 522
  • [38] Detection of lung cancer using single-exposure dual-energy subtraction chest radiography
    Ide K.
    Mogami H.
    Murakami T.
    Yasuhara Y.
    Miyagawa M.
    Mochizuki T.
    Radiation Medicine, 2007, 25 (5): : 195 - 201
  • [39] Differentiation of small intrahepatic mass-forming cholangiocarcinoma from small liver abscess by dual source dual-energy CT quantitative parameters
    Kim, Ji Eun
    Kim, Hyun Ok
    Bae, Kyungsoo
    Cho, Jae Min
    Choi, Ho Cheol
    Choi, Dae Seob
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 92 : 145 - 152
  • [40] Cancer Patient-Derived Circulating Microparticles Enhance Lung Metastasis in a Rat Model: Dual-Source CT, Cellular, and Molecular Studies
    Ko, Sheung-Fat
    Yip, Hon-Kan
    Zhen, Yen-Yi
    Lee, Chia-Chang
    Li, Jung-Hui
    Lee, Chen-Chang
    Leu, Steve
    Huang, Chung-Cheng
    Ng, Shu-Hang
    Lin, Jui-Wei
    MOLECULAR IMAGING AND BIOLOGY, 2016, 18 (04) : 490 - 499