Value of dual-source CT dual-energy parameters combined with serum detection of VEGF and CEA in the diagnosis of early lung cancer

被引:3
|
作者
Ren, Liliang [1 ]
Yang, Yulong [2 ]
机构
[1] Yantai Mt Hosp, Imaging Dept, Yantai, Shandong, Peoples R China
[2] Hebei Yanda Hosp, Dept Resp & Crit Care Med, West Side Sibolan West Rd, Langfang 065200, Hebei, Peoples R China
关键词
Dual-source CT; dual-energy; VEGF; CEA; lung cancer; CYFRA21-1; NSE;
D O I
10.1080/02648725.2023.2166708
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
To discuss the value of dual-source CT dual-energy parameters combined with serum detection of vascular endothelial growth factor (VEGF) and carcinoembryonic antigen (CEA) in the diagnosis of early lung cancer (LC). In total, 100 patients with lung lesions in our hospital from January 2020 to January 2022 were selected for retrospective study, and were divided into the lung cancer group (group A) and benign lung disease group (group B) according to the final results of pathological diagnosis, using dual-source CT dual-energy scanning combined with serum detection of VEGF and CEA to analyze the diagnostic values of single detection and combined detection. Among the 100 patients with lung lesions, there were 58 patients with LC and 42 patients with benign lung diseases after pathological examination, with no statistical difference in normalized iodine concentration (NIC) and the increased value of iodine at arterial phase between the two groups (P > 0.05). The NIC value of group A was higher than group B at venous phase (P < 0.05). The serum levels of VEGF and CEA in group A were higher than group B (P < 0.05). The area under the curve, specificity, sensitivity, Youden index and 95% CI of combined diagnosis were higher than single detection of NIC, VEGF and CEA at venous phase. The combined application of dual-source CT dual-energy parameters and serum detection of VEGF and CEA has higher diagnostic value in patients with early LC, which can provide effective reference for clinical diagnosis and treatment, with higher application value in clinic.
引用
收藏
页码:1000 / 1011
页数:12
相关论文
共 50 条
  • [21] Dual-energy CT Radiomics Combined with Quantitative Parameters for Differentiating Lung Adenocarcinoma From Squamous Cell Carcinoma: A Dual-center Study
    Lin, Ze
    Liu, Ying
    Xia, Chengcheng
    Huang, Pei
    Peng, Zhiwei
    Yi, Li
    Wang, Yu
    Yu, Xiao
    Fan, Bing
    Zuo, Minjing
    ACADEMIC RADIOLOGY, 2025, 32 (03) : 1675 - 1684
  • [22] Optimization of keV-settings in abdominal and lower extremity dual-source dual-energy CT angiography determined with virtual monoenergetic imaging
    Sudarski, Sonja
    Apfaltrer, Paul
    Nance, John W., Jr.
    Schneider, David
    Meyer, Mathias
    Schoenberg, Stefan O.
    Fink, Christian
    Henzler, Thomas
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (10) : E574 - E581
  • [23] Dual-Energy CT Material Decomposition: The Value in the Detection of Lymph Node Metastasis from Breast Cancer
    Yel, Ibrahim
    D'Angelo, Tommaso
    Gruenewald, Leon D.
    Koch, Vitali
    Golbach, Rejane
    Mahmoudi, Scherwin
    Ascenti, Giorgio
    Blandino, Alfredo
    Vogl, Thomas J.
    Booz, Christian
    Bucolo, Giuseppe M.
    DIAGNOSTICS, 2024, 14 (05)
  • [24] Comparison of dual-source computed tomography (CT) dual-energy angiography with conventional 3D imaging towards caudomedial vessels
    Li, Daowei
    Liu, Na
    Ma, Qiang
    He, Dan
    BIOMEDICAL RESEARCH-INDIA, 2017, 28 (12): : 5445 - 5449
  • [25] Comparison of Dual- and Single-Source Dual-Energy CT for Diagnosis of Acute Pulmonary Artery Embolism
    Petritsch, Bernhard
    Pannenbecker, Pauline
    Weng, Andreas Max
    Veldhoen, Simon
    Grunz, Jan-Peter
    Bley, Thorsten Alexander
    Kosmala, Aleksander
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2021, 193 (04): : 427 - 436
  • [26] Dual-phase dual-energy CT in patients with lung cancer: assessment of the additional value of iodine quantification in lymph node therapy response
    Baxa, Jan
    Vondrakova, Alena
    Matouskova, Tana
    Ruzickova, Olga
    Schmidt, Bernhard
    Flohr, Thomas
    Sedlmair, Martin
    Ferda, Jiri
    EUROPEAN RADIOLOGY, 2014, 24 (08) : 1981 - 1988
  • [27] Correlation of iodine uptake and perfusion parameters between dual-energy CT imaging and first-pass dual-input perfusion CT in lung cancer
    Chen, Xiaoliang
    Xu, Yanyan
    Duan, Jianghui
    Li, Chuandong
    Sun, Hongliang
    Wang, Wu
    MEDICINE, 2017, 96 (28)
  • [28] Dual-phase dual-energy CT in patients with lung cancer: assessment of the additional value of iodine quantification in lymph node therapy response
    Jan Baxa
    Alena Vondráková
    Táňa Matoušková
    Olga Růžičková
    Bernhard Schmidt
    Thomas Flohr
    Martin Sedlmair
    Jiří Ferda
    European Radiology, 2014, 24 : 1981 - 1988
  • [29] Differential diagnosis of osteoblastic metastases from bone islands in patients with lung cancer by single-source dual-energy CT: Advantages of spectral CT imaging
    Dong Yue
    Zheng Shaowei
    Machida, Haruhiko
    Wang Bing
    Liu Ailian
    Liu Yijun
    Zhang Xin
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (05) : 901 - 907
  • [30] Dual-Source Dual-Energy CT Portal Venous Phase Abdominal CT Scans in Large Body Habitus Patients: Preliminary Observations on Image Quality and Material Decomposition
    Baliyan, Vinit
    Kordbacheh, Hamed
    Serrao, Jessica
    Sahani, Dushyant V.
    Kambadakone, Avinash R.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (06) : 932 - 936