Value of dual-source CT dual-energy parameters combined with serum detection of VEGF and CEA in the diagnosis of early lung cancer

被引:3
|
作者
Ren, Liliang [1 ]
Yang, Yulong [2 ]
机构
[1] Yantai Mt Hosp, Imaging Dept, Yantai, Shandong, Peoples R China
[2] Hebei Yanda Hosp, Dept Resp & Crit Care Med, West Side Sibolan West Rd, Langfang 065200, Hebei, Peoples R China
关键词
Dual-source CT; dual-energy; VEGF; CEA; lung cancer; CYFRA21-1; NSE;
D O I
10.1080/02648725.2023.2166708
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
To discuss the value of dual-source CT dual-energy parameters combined with serum detection of vascular endothelial growth factor (VEGF) and carcinoembryonic antigen (CEA) in the diagnosis of early lung cancer (LC). In total, 100 patients with lung lesions in our hospital from January 2020 to January 2022 were selected for retrospective study, and were divided into the lung cancer group (group A) and benign lung disease group (group B) according to the final results of pathological diagnosis, using dual-source CT dual-energy scanning combined with serum detection of VEGF and CEA to analyze the diagnostic values of single detection and combined detection. Among the 100 patients with lung lesions, there were 58 patients with LC and 42 patients with benign lung diseases after pathological examination, with no statistical difference in normalized iodine concentration (NIC) and the increased value of iodine at arterial phase between the two groups (P > 0.05). The NIC value of group A was higher than group B at venous phase (P < 0.05). The serum levels of VEGF and CEA in group A were higher than group B (P < 0.05). The area under the curve, specificity, sensitivity, Youden index and 95% CI of combined diagnosis were higher than single detection of NIC, VEGF and CEA at venous phase. The combined application of dual-source CT dual-energy parameters and serum detection of VEGF and CEA has higher diagnostic value in patients with early LC, which can provide effective reference for clinical diagnosis and treatment, with higher application value in clinic.
引用
收藏
页码:1000 / 1011
页数:12
相关论文
共 50 条
  • [1] Comparison of serum tumor markers combined with dual-source CT in the diagnosis of lung cancer
    Shan, Yuqing
    Yin, Xiangyuan
    Zhao, Na
    Wang, Jie
    Yang, Shouxiang
    MINERVA MEDICA, 2023, 114 (06) : 795 - 801
  • [2] Dual-Energy and Dual-Source CT: Is There a Role in the Abdomen and Pelvis?
    Fletcher, Joel G.
    Takahashi, Naoki
    Hartman, Robert
    Guimaraes, Luis
    Huprich, James E.
    Hough, David M.
    Yu, Lifeng
    McCollough, Cynthia H.
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2009, 47 (01) : 41 - +
  • [3] Initial experience of dual-energy lung perfusion CT using a dual-source CT system in children
    Goo, Hyun Woo
    PEDIATRIC RADIOLOGY, 2010, 40 (09) : 1536 - 1544
  • [4] Initial experience of dual-energy lung perfusion CT using a dual-source CT system in children
    Hyun Woo Goo
    Pediatric Radiology, 2010, 40 : 1536 - 1544
  • [5] Dual-Source Dual-Energy CT in Submandibular Sialolithiasis: Reliability and Radiation Burden
    Pulickal, Geoiphy George
    Singh, Dinesh
    Lohan, Rahul
    Chawla, Ashish
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 213 (06) : 1291 - 1296
  • [6] Quantitative imaging of chemical composition using dual-energy, dual-source CT
    Liu, Xin
    Primak, Andrew N.
    Yu, Lifeng
    McCollough, Cynthia H.
    Morin, Richard L.
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [7] In vivo measurement of iron concentration using dual-source, dual-energy CT
    Weavers, Paul T.
    Jacobsen, Megan
    Liu, Xin
    Morin, Richard L.
    McCollough, Cynthia H.
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [8] Review of the application of dual-energy CT combined with radiomics in the diagnosis and analysis of lung cancer
    Zhang, Rongyu
    Zheng, Hao
    Lin, Jie
    Wang, Junna
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2025, 26 (04):
  • [9] Dual-energy perfusion CT of non-diseased lung segments using dual-source CT: correlation with perfusion SPECT
    Kunihiro, Yoshie
    Okada, Munemasa
    Matsunaga, Naofumi
    Sano, Yuichi
    Kudomi, Shohei
    Suga, Kazuyoshi
    Kido, Shoji
    JAPANESE JOURNAL OF RADIOLOGY, 2013, 31 (02) : 99 - 104
  • [10] Diagnostic value of Flash dual-source CT coronary artery imaging combined with dual-energy myocardial perfusion imaging for coronary heart disease
    Zhao, Rui-Ping
    Hao, Zhi-Ru
    Song, Zhi-Jun
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2014, 7 (04) : 865 - 868