Validation of an accelerometer system for measuring physical activity and sedentary behavior in healthy children and adolescents

被引:4
作者
Milther, Camilla [1 ]
Winther, Laerke [1 ]
Stahlhut, Michelle [2 ,3 ]
Curtis, Derek John [4 ]
Aadahl, Mette [2 ,5 ]
Kristensen, Morten Tange [3 ,5 ,6 ]
Sorensen, Jette Led [1 ,5 ]
Dall, Christian Have [3 ,5 ,6 ]
机构
[1] Mary Elizabeths Hosp, Rigshosp, Copenhagen, Denmark
[2] Copenhagen Univ Hosp, Ctr Clin Res & Prevent, Bispebjerg, Denmark
[3] Copenhagen Univ Hosp, Frederiksberg, Denmark
[4] Child Ctr Copenhagen, Child & Youth Adm, Copenhagen, Denmark
[5] Univ Copenhagen, Inst Clin Med, Copenhagen, Denmark
[6] Copenhagen Univ Hosp, Dept Phys & Occupat Therapy, Bispebjerg, Denmark
关键词
Validity; Accelerometer; Children; Adolescents; Physical activity; Sedentary behavior; ACTIVITY MONITOR; CEREBRAL-PALSY; VALIDITY; RELIABILITY; COMPARABILITY; AGREEMENT; YOUTH;
D O I
10.1007/s00431-023-05014-z
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
The study aims to assess the concurrent validity of the SENS -motion (R) accelerometer system for device-based measurement of physical activity and sedentary behavior in healthy children and adolescents. Thirty-six healthy children and adolescents (mean +/- standard deviation (SD) age, 10.2 +/- 2.3 years) were fitted with three SENS sensors while performing standardized activities including walking, fast walking, sitting/lying, and arm movements. Data from the sensors were compared with video observations (reference criteria). The agreement between SENS -motion((R)) and observation was analyzed using Student's t-test and illustrated in Bland-Altman plots. The concurrent validity was further evaluated using intraclass correlation coefficient (ICC) and was expressed as standard error of measurement (SEM) and minimal detectable change (MDC). Strong agreement was found between SENS and observation for walking time, sedentary time, and lying time. In contrast, moderate agreement was observed for number of steps, sitting time, and time with and without arm movement. -ICC2.1 values were overall moderate to excellent (0.5-0.94), with correspondingly low SEM% for walking time, sedentary time, lying time, and time with arm movement (2-9%). An acceptable SEM% level was reached for both steps and sitting time (11% and 12%). For fast walking time, the results showed a weak agreement between the measurement methods, and the ICC value was poor. Conclusion: SENS -motion((R)) seems valid for detecting physical activity and sedentary behavior in healthy children and adolescents with strong agreement and moderate to excellent ICC values. Furthermore, the explorative results on arm movements seem promising.
引用
收藏
页码:3639 / 3647
页数:9
相关论文
共 41 条
[1]   Examining the validity of the ActivPAL monitor in measuring posture and ambulatory movement in children [J].
Aminian, Saeideh ;
Hinckson, Erica A. .
INTERNATIONAL JOURNAL OF BEHAVIORAL NUTRITION AND PHYSICAL ACTIVITY, 2012, 9
[2]   Measurement of physical activity in clinical practice using accelerometers [J].
Arvidsson, D. ;
Fridoltsson, J. ;
Borjesson, M. .
JOURNAL OF INTERNAL MEDICINE, 2019, 286 (02) :137-153
[3]   THE LEVEL AND TEMPO OF CHILDRENS PHYSICAL ACTIVITIES - AN OBSERVATIONAL STUDY [J].
BAILEY, RC ;
OLSON, J ;
PEPPER, SL ;
PORSZASZ, J ;
BARSTOW, TJ ;
COOPER, DM .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1995, 27 (07) :1033-1041
[4]   Reliability and Construct Validity of the SENS Motion (R) Activity Measurement System as a Tool to Detect Sedentary Behaviour in Patients with Knee Osteoarthritis [J].
Bartholdy, Cecilie ;
Gudbergsen, Henrik ;
Bliddal, Henning ;
Kjaergaard, Morten ;
Lykkegaard, Kasper Lundberg ;
Henriksen, Marius .
ARTHRITIS, 2018,
[5]   Smallest real difference, a link between reproducibility and responsiveness [J].
Beckerman, H ;
Roebroeck, ME ;
Lankhorst, GJ ;
Becher, JG ;
Bezemer, PD ;
Verbeek, ALM .
QUALITY OF LIFE RESEARCH, 2001, 10 (07) :571-578
[6]  
Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
[7]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[8]   Validation of the Phillips et al. GENEActiv accelerometer wrist cut-points in children aged 5-8 years old [J].
Duncan, Michael J. ;
Wilson, Susie ;
Tallis, Jason ;
Eyre, Emma .
EUROPEAN JOURNAL OF PEDIATRICS, 2016, 175 (12) :2019-2021
[9]   Validity and Comparability of a Wrist-Worn Accelerometer in Children [J].
Ekblom, Orjan ;
Nyberg, Gisela ;
Bak, Elin Ekblom ;
Ekelund, Ulf ;
Marcus, Claude .
JOURNAL OF PHYSICAL ACTIVITY & HEALTH, 2012, 9 (03) :389-393
[10]  
Elhakeem A, 2015, INT J BEHAV NUTR PHY, V12, DOI [10.1186/s12966-015-0274-5, 10.1186/s12966-015-0250-0]