Performance investigation on the bypass ejector for a proton exchange membrane fuel cell system

被引:12
作者
Han, Jiquan [1 ,2 ]
Besagni, Giorgio [1 ]
Mereu, Riccardo [1 ]
Inzoli, Fabio [1 ]
Feng, Jianmei [2 ]
Peng, Xueyuan [2 ,3 ]
机构
[1] Politen Milano, Dept Energy, Via Lambruschini 4, I-20156 Milan, Italy
[2] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Xian 710049, Peoples R China
[3] Xi An Jiao Tong Univ, State Key Lab Multiphase Flow Power Engn, Xian 710049, Peoples R China
关键词
Ejector; Proton exchange membrane fuel cell; Hydrogen recirculation; Computational fluid dynamics; COMPUTATIONAL FLUID-DYNAMICS; R744 2-PHASE EJECTOR; STEAM EJECTOR; STRUCTURE OPTIMIZATION; AUXILIARY ENTRAINMENT; RECIRCULATION SYSTEM; NUMERICAL ASSESSMENT; NOZZLE EJECTOR; REFRIGERATION; DESIGN;
D O I
10.1016/j.applthermaleng.2024.122349
中图分类号
O414.1 [热力学];
学科分类号
摘要
The poor entrainment performance of the conventional ejector is a significant problem that makes it hard to use in proton exchange membrane fuel cell (PEMFC) systems. This study aims to evaluate the entrainment performance of a bypass ejector for a 100 kW PEMFC system. The effects of three critical geometric parameters, namely the axial position, width, and angle of the bypass inlet, on the entrainment performance are thoroughly investigated. The results demonstrate that the bypass flow exhibits a significant performance improvement in the critical mode. In contrast, the performance improvement is negligible and even negative in the subcritical mode. After careful evaluation of the entrainment performance across various stack powers, the optimal axial position, width, and angle of the bypass inlet are found to be 1.1, 2 mm, and 10(degrees), respectively. A comparative analysis between the bypass ejector and the conventional ejector underscores a significant advantage for the former, exhibiting a remarkable 22.1 % increase in the hydrogen entrainment ratio at the stack power of 101 kW. Nevertheless, the entrainment performance of the bypass ejector diminishes when operating at low stack powers below 24 kW.
引用
收藏
页数:20
相关论文
共 50 条
[21]   Comprehensive Experimental Investigation of Operational Parameter Sensitivity in Proton Exchange Membrane Fuel Cell Performance [J].
Feng, Renhua ;
Hua, Zhanye ;
Yu, Jing ;
Wang, Shaoyang ;
Shi, Laihua ;
Shu, Xing ;
Yan, Ziyi ;
Guo, Jiayi .
BATTERIES-BASEL, 2025, 11 (07)
[22]   Numerical investigation of gas channel shape effect on proton exchange membrane fuel cell performance [J].
Rezazadeh, Sajad ;
Ahmadi, Nima .
JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2015, 37 (03) :789-802
[23]   Passive hydrogen recovery schemes using a vacuum ejector in a proton exchange membrane fuel cell system [J].
Hwang, Jenn-Jiang .
JOURNAL OF POWER SOURCES, 2014, 247 :256-263
[24]   Numerical investigation of gas channel shape effect on proton exchange membrane fuel cell performance [J].
Sajad Rezazadeh ;
Nima Ahmadi .
Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2015, 37 :789-802
[25]   A comparative study of single and dual ejector concepts for anodic recirculation system in high-performance vehicular proton exchange membrane fuel cells [J].
Tri, Dat Truong Le ;
Vu, Hoang Nghia ;
Nguyen, Huu Linh ;
Kim, Younghyeon ;
Yu, Sangseok .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2023, 48 (70) :27344-27360
[26]   Performance of a membrane humidifier for a proton exchange membrane fuel cell [J].
Li Z.-Y. ;
Li N. ;
Li Q.-Y. ;
Bao C. ;
Teng Y. .
Gongcheng Kexue Xuebao/Chinese Journal of Engineering, 2022, 44 (06) :1090-1097
[27]   Numerical studies on wide-operating-range ejector based on anodic pressure drop characteristics in proton exchange membrane fuel cell system [J].
Pei, Pucheng ;
Ren, Peng ;
Li, Yuehua ;
Wu, Ziyao ;
Chen, Dongfang ;
Huang, Shangwei ;
Jia, Xiaoning .
APPLIED ENERGY, 2019, 235 :729-738
[28]   Regulation of anode gas pressure for durable and secure operation of proton exchange membrane fuel cells with variable-flow-rate ejector [J].
Tri, Dat Truong Le ;
Nguyen, Huu Linh ;
Woo, Jongbin ;
Kim, Younghyeon ;
Yu, Sangseok .
CASE STUDIES IN THERMAL ENGINEERING, 2024, 60
[29]   Effects of Different Channel Geometries of Metallic Bipolar Plates on Proton Exchange Membrane Fuel Cell Performance [J].
Busque, Raquel ;
Bossio, Matias ;
Brigido, Albert ;
Lara, Antoni .
ENERGIES, 2023, 16 (23)
[30]   Performance of a proton exchange membrane fuel cell stack [J].
Johnson, R ;
Morgan, C ;
Witmer, D ;
Johnson, T .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2001, 26 (08) :879-887