Operation characteristics based on a novel performance model based on capacity utilization rate of a variable refrigerant flow air conditioning system

被引:3
作者
Xiao, Hansong [1 ,2 ]
Liu, Shurong [1 ,2 ]
Ding, Yunxiao [3 ]
Zheng, Chunyuan [3 ]
Luo, Bing [1 ,2 ,3 ]
Niu, Heng [1 ,2 ]
Shi, Jingfeng [1 ,2 ]
Wang, Baolong [1 ,2 ]
Song, Qiang [4 ]
Shi, Wenxing [1 ,2 ]
机构
[1] Tsinghua Univ, Dept Bldg Sci, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Sch Architecture, Beijing Key Lab Indoor Air Qual Evaluat & Control, Beijing 100084, Peoples R China
[3] GD Midea Heating &Ventilating Equipment Co Ltd, Lanzhou 528311, Guangdong, Peoples R China
[4] Haier A C Elect Co Ltd, Qingdao 266101, Peoples R China
关键词
Variable refrigerant flow; Air conditioning system; Energy efficiency; Indoor unit; Performance model; SIMULATION;
D O I
10.1016/j.enbuild.2023.113253
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the context of a large market share, enhancing the actual performance of variable refrigerant flow (VRF) airconditioning systems is of considerable importance. The operating states of indoor units (IUs) significantly influence the energy efficiency of a VRF system with multiple indoor terminals. Therefore, it is challenging to address accurate and concise representation of the operational characteristics of IUs for analyzing their impact on system performance. This study explored a novel performance index called capacity utilization rate (CUR) to illustrate the effect of IUs on system performance and developed a performance model based on this index. Simulation and experimental results demonstrated that energy efficiency and evaporating temperature decrease with a reduction in CUR under specific ambient temperatures and part-load rates. The proposed performance model was applied to real buildings in field tests to examine the operational characteristics of the VRF system. This research offers valuable insights for system design, performance simulation, and performance evaluation of VRF systems.
引用
收藏
页数:14
相关论文
共 34 条
  • [21] Su Y., 2017, ANN ACAD C CHIN ASS
  • [22] Control strategy of compressor and sub-cooler in variable refrigerant flow air conditioning system for high EER and comfortable indoor environment
    Tu, Qiu
    Zhang, Lina
    Cai, Wei
    Guo, Xiujuan
    Yuan, Xiaojun
    Deng, Chenmian
    Zhang, Jie
    [J]. APPLIED THERMAL ENGINEERING, 2018, 141 : 215 - 225
  • [23] Frosting performance variations of variable-frequency air source heat pump in different climatic regions
    Wei, Wenzhe
    Jin, Xinyue
    Dong, Qian
    Ni, Long
    Zhao, Shunan
    Wang, Wei
    Sun, Yuying
    [J]. APPLIED THERMAL ENGINEERING, 2023, 219
  • [24] Precision improvement method for onsite performance measurement of variable refrigerant flow system
    Xiao, Hansong
    Shi, Jingfeng
    Yang, Zixu
    Wang, Baolong
    Shi, Wenxing
    Li, Meng
    [J]. BUILDING AND ENVIRONMENT, 2022, 208
  • [25] All-condition measuring methods for field performance of room air conditioner
    Yang, Zixu
    Ding, Lianrui
    Xiao, Hansong
    Zhang, Guohui
    Wang, Baolong
    Shi, Wenxing
    [J]. APPLIED THERMAL ENGINEERING, 2020, 180
  • [26] Zhang G., 2020, RES MEASUREMENT METH
  • [27] Simulations of the energy performance of variable refrigerant flow system in representative operation modes for residential buildings in the hot summer and cold winter region in China
    Zhang, Guohui
    Li, Xianting
    Shi, Wenxing
    Wang, Baolong
    Li, Ziai
    Cao, Yang
    [J]. ENERGY AND BUILDINGS, 2018, 174 : 414 - 427
  • [28] Refrigerant charge fault diagnosis strategy for VRF systems based on stacking ensemble learning
    Zhang, Li
    Cheng, Yahao
    Zhang, Jianxin
    Chen, Huanxin
    Cheng, Hengda
    Gou, Wei
    [J]. BUILDING AND ENVIRONMENT, 2023, 234
  • [29] [赵德印 Zhao Deyin], 2016, [同济大学学报. 自然科学版, Journal of Tongji University. Natural Science], V44, P915
  • [30] Zhao W., 2010, HEAT VENT AIR COND, V40, P98