Flash evaporation strategy of organic Rankine cycle for geothermal power performance enhancement: A case study

被引:9
作者
Xie, Yingchun [1 ]
Nie, Yutai [2 ]
Li, Tailu [3 ,4 ]
Zhang, Yao [3 ]
Wang, Jingyi [3 ]
机构
[1] Tianjin Univ, Sch Environm Sci & Engn, Tianjin 300350, Peoples R China
[2] Xian Jiaotong Liverpool Univ, Sch Adv Technol, Suzhou 215123, Peoples R China
[3] Hebei Univ Technol, Sch Energy & Environm Engn, Tianjin 300401, Peoples R China
[4] Hebei Univ Technol, Energy & Environm Engn, Xiping Rd, Tianjin 300401, Peoples R China
基金
中国国家自然科学基金;
关键词
Flash evaporation; Organic rankine cycle; Organic rankine flash cycle; Thermodynamic performance; Geothermal power generation; WORKING FLUID SELECTION; WASTE HEAT-RECOVERY; EXERGY ANALYSIS; FUEL-CELL; ENERGY; ORC; OPTIMIZATION; GENERATION; SYSTEM; RESOURCES;
D O I
10.1016/j.renene.2023.05.065
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The performance of organic Rankine cycle (ORC) is poor due to the high irreversible losses in evaporator. To improve system performance, organic Rankine single flash cycle (ORSFC) and organic Rankine double flash cycle (ORDFC) are proposed, in which the traditional evaporation process is split into incomplete evaporation and flash evaporation. Thermal and exergetic efficiencies are taken as the objective functions, and the effects of the related operating parameters and the number of the flash stage on the thermodynamic performance of the system is conducted. The results show that for the ORSFC and ORDFC, in the direction of the rise of the heat source temperature, the net power output increases, the optimal evaporation temperature and flash temperature corresponding to different performance criteria also gradually increase. Besides, the dryness of the evaporator outlet is inversely proportional to the net power output, while it is directly proportional to the system efficiencies. When the dryness increases by 0.1, the net power output of the ORSFC and ORDFC decreases by an average of 148.5 kW, the thermal efficiency and exergetic efficiency of the ORSFC and ORDFC increase by an average of 0.56% and 1.37%, respectively. Moreover, with the flash stages increase, the performance criteria are improved at different magnitude. When a specific thermodynamic parameter is optimized, the ORDFC always obtains the best value for this parameter.
引用
收藏
页码:57 / 69
页数:13
相关论文
共 46 条
[41]   Study of working fluid selection of organic Rankine cycle (ORC) for engine waste heat recovery [J].
Wang, E. H. ;
Zhang, H. G. ;
Fan, B. Y. ;
Ouyang, M. G. ;
Zhao, Y. ;
Mu, Q. H. .
ENERGY, 2011, 36 (05) :3406-3418
[42]  
[王贵玲 Wang Guiling], 2020, [地学前缘, Earth Science Frontiers], V27, P1, DOI 10.13745/j.esf.2020.1.1
[43]   Working Fluids Selection for Flashing Organic Rankine Regeneration Cycle Driven by Low-Medium Heat Source [J].
Wang, Lingbao ;
Bu, Xianbiao ;
Li, Huashan ;
Wang, Hanzhi ;
Ma, Weibin .
ENVIRONMENTAL PROGRESS & SUSTAINABLE ENERGY, 2018, 37 (03) :1201-1209
[44]   Thermodynamic analysis and optimization of four organic flash cycle systems for waste heat recovery [J].
Wang, Qi ;
Wu, Weifeng ;
Li, Dantong ;
Wang, Jiangfeng ;
He, Zhilong .
ENERGY CONVERSION AND MANAGEMENT, 2020, 221
[45]   Cycle and turbine optimisation for an ORC operating with two-phase expansion [J].
White, Martin T. .
APPLIED THERMAL ENGINEERING, 2021, 192
[46]   A review of geothermal energy resources, development, and applications in China: Current status and prospects [J].
Zhu, Jialing ;
Hu, Kaiyong ;
Lu, Xinli ;
Huang, Xiaoxue ;
Liu, Ketao ;
Wu, Xiujie .
ENERGY, 2015, 93 :466-483