Preparation and Application of a Fast, Naked-Eye, Highly Selective, and Highly Sensitive Fluorescent Probe of Schiff Base for Detection of Cu2+

被引:7
作者
Liu, Juan [1 ]
Cheng, Peng-Yu [1 ]
Chen, Sai [1 ]
Wang, Meng [1 ]
Wei, Kai [1 ]
Li, Yuan [1 ]
Cao, Yao-Yao [1 ]
Wang, Xing [2 ]
Li, Hong-Lei [1 ]
机构
[1] Nanjing Med Univ, Dept Pharm, Kangda Coll, Lianyungang 222000, Peoples R China
[2] China Pharmaceut Univ, Sch Pharm, Nanjing 211198, Peoples R China
关键词
fluorescent probe of Schiff base; copper ion; high sensitivity and selectivity; good anti-interference ability; low detection limit; COPPER IONS; COUMARIN; CHEMOSENSOR; SENSOR; RECOGNITION; DISORDERS; DFT;
D O I
10.3390/chemosensors11110556
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fluorescent probe, N '-((3-methyl-5-oxo-1-phenyl-4, 5-dihydro-1H-pyrazol-4-yl) methylene)-2-oxo-2H-chromene-3-carbohydrazide (MPMC), was synthesized and characterized. Characterizations of the synthetic MPMC were conducted via proton nuclear magnetic resonance ((HNMR)-H-1) spectroscopy and carbon-13 nuclear magnetic resonance spectroscopy (C-13 NMR). The fluorescence emission behaviors of the MPMC probe towards diverse metal ions were detected, and the probe exhibited high sensitivity and selectivity towards Cu2+ over other metal ions via the quenching of its fluorescence. Furthermore, the existence of other metal actions made no apparent difference to the fluorescence intensity of the MPMC-Cu2+ system; that is, MPMC displayed a good anti-interference ability. Job's plot of the MPMC and copper ions indicated that the detection limit was 10.23 nM (R-2 = 0.9612) for the assayed actions, with a stoichiometric ratio of 1:1 for MPMC and Cu2+. Additionally, the color of the MPMC probe solution changed from nearly colorless to yellow in the presence of Cu2+ in visible light, and the color change could be observed by the naked eye. Similarly, the color resolved from bright yellow into blue in ultraviolet light. Moreover, reusability studies indicated that the MPMC probe was reusable. The pH effect of the MPMC probe on Cu2+ had a broad range of pH detection, i.e., from 4.0 to 11.0. The response time of the MPMC probe for determining Cu2+ was within 1 min. The recognition of Cu2+ via MPMC performed on pre-treated paper under sunlight and UV light both had a distinct colour change. Thus, the solid-state method for detecting Cu2+ with the naked eye was both economical and convenient.
引用
收藏
页数:14
相关论文
共 42 条
[1]   Reversed-phase switchable-hydrophilicity solvent liquid-liquid microextraction of copper prior to its determination by smartphone digital image colorimetry [J].
Al-Nidawi, Mais ;
Alshana, Usama .
JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2021, 104
[2]   Gold nanostar-enhanced chemiluminescence probe for highly sensitive detection of Cu(II) ions [J].
Amjadi, Mohammad ;
Abolghasemi-Fakhri, Zahra .
SENSORS AND ACTUATORS B-CHEMICAL, 2018, 257 :629-634
[3]   Quinazoline copper(II) ensemble as turn-on fluorescence sensor for cysteine and chemodosimeter for NO [J].
Anand, Thangaraj ;
Sivaraman, Gandhi ;
Chellappa, Duraisamy .
JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2014, 281 :47-52
[4]   Fluorescence "Turn On-Off" Sensing of Copper (II) Ions Utilizing Coumarin-Based Chemosensor: Experimental Study, Theoretical Calculation, Mineral and Drinking Water Analysis [J].
Arslan, Fatma Nur ;
Geyik, Gonul Akin ;
Koran, Kenan ;
Ozen, Furkan ;
Aydin, Duygu ;
Elmas, Sukriye Nihan Karuk ;
Gorgulu, Ahmet Orhan ;
Yilmaz, Ibrahim .
JOURNAL OF FLUORESCENCE, 2020, 30 (02) :317-327
[5]   A coumarin-pyrazolone based fluorescent probe for selective colorimetric and fluorimetric fluoride detection: Synthesis, spectroscopic properties and DFT calculations [J].
Babur, Banu ;
Seferoglu, Nurgul ;
Seferoglu, Zeynel .
JOURNAL OF MOLECULAR STRUCTURE, 2018, 1161 :218-225
[6]   A novel fluorescence turn-on coumarin-pyrazolone based monomethine probe for biothiol detection [J].
Babur, Banu ;
Seferoglu, Nurgul ;
Ocal, Muge ;
Sonugur, Gizem ;
Akbulut, Hakan ;
Seferoglu, Zeynel .
TETRAHEDRON, 2016, 72 (30) :4498-4502
[7]   Detection of radium at the attogram per gram level in copper by inductively coupled plasma mass spectrometry after cation-exchange chromatography [J].
Bonin, Melodie ;
Lariviere, Dominic ;
Povinec, Pavel P. .
ANALYTICAL METHODS, 2020, 12 (17) :2272-2278
[8]   Copper homeostasis and neurodegenerative disorders (Alzheimer's, prion, and Parkinson's diseases and amyotrophic lateral sclerosis) [J].
Gaggelli, Elena ;
Kozlowski, Henryk ;
Valensin, Daniela ;
Valensin, Gianni .
CHEMICAL REVIEWS, 2006, 106 (06) :1995-2044
[9]   Multivariate Optimization of Ultrasound-Assisted Extraction Procedure for the Determination of Ca, Fe, K, Mg, Mn, P, and Zn in Pepper Samples by ICP OES [J].
Gamela, Raimundo R. ;
Costa, Vinicius C. ;
Pereira-Filho, Edenir R. .
FOOD ANALYTICAL METHODS, 2020, 13 (01) :69-77
[10]   Synthesis and application of a "turn on" fluorescent probe for glutathione based on a copper complex of coumarin hydrazide Schiff base derivative [J].
He, Guangjie ;
Hua, Xiaobo ;
Yang, Nan ;
Li, Linlin ;
Xu, Jinhe ;
Yang, Linlin ;
Wang, Qingzhi ;
Ji, Liguo .
BIOORGANIC CHEMISTRY, 2019, 91