Establishing local diagnostic reference levels for computed tomography examinations using size-specific dose estimates

被引:6
|
作者
Alrehily, Faisal A. [1 ]
Alqahtani, Khalid S. [1 ]
Aljohani, Marwan H. [1 ]
Alharbi, Nawaf S. [1 ]
Alharbi, Reyan M. [2 ]
Abdulaal, Osamah M. [1 ]
Alshamrani, Abdullah F. [1 ]
Alsaedi, Abdulrahman S. [3 ]
Al-Murshedi, Sadeq H. [4 ,5 ]
Alhazmi, Fahad H. [1 ]
机构
[1] Taibah Univ, Dept Diag Radiol Technol, Coll Appl Med Sci, Al Madinah Al Munawwarah, Saudi Arabia
[2] King Salman bin Abdulaziz Med City, Dept Radiol, Riyadh, Saudi Arabia
[3] King Fahad Gen Hosp, Dept Nucl Med, Al Madinah Al Munawwarah, Saudi Arabia
[4] AL Zahraa Univ Women, Coll Hlth & Med Technol, Dept Radiol Tech, Karbala, Iraq
[5] Univ Babylon, Coll Educ Pure Sci, Phys Dept, Babylon, Iraq
关键词
CT; DRL; CTDIvol; DLP; SSDE; effective diameter; CT; RADIATION; WEIGHT; CANCER; CHEST;
D O I
10.15537/smj.2023.44.8.20230230
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: To establish local DRL (LDRL) for computed tomography (CT) examinations based on size-specific dose estimates (SSDEs), which consider patient size. The concept of diagnostic reference level (DRL) was introduced to limit patient exposure to unnecessary radiation. However, traditional DRL values do not consider patient size. Methods: Following institutional committee approval, data were collected from CT examinations of adult patients at Madinah General Hospital, Al Madinah Al Munawwarah, Saudi Arabia from January to March 2023. The SSDE was calculated for each patient using the effective diameter (D-eff). Results: The LDRLs of the brain, cervical spine, chest, thoracic spine and kidneys, ureters, and bladder (KUB) examinations were 118 mGy, 12 mGy, 8 mGy, 17 mGy, and 7 mGy, respectively. A strong correlation was observed between SSDEs and the volume computed tomography dose index (CTDIvol) for all examinations except chest scans (p<0.05). Size-specific dose estimates were higher than the CTDIvol, with a greater difference for patients with smaller Deff (p<0.05). Conclusion: The established LDRL was within the international DRL. The use of SSDE has the potential to provide more accurate and relevant data for radiation safety practices; however, widespread adoption of SSDE in new CT scanners is necessary for promoting consistency and standardization methodologies.
引用
收藏
页码:761 / 766
页数:6
相关论文
共 50 条
  • [21] Diagnostic reference levels for routine computed tomography angiography examinations: a systematic review
    Alhailiy, Ali Bahny
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2024, 55 (01):
  • [22] Diagnostic reference levels for computed tomography examinations in pediatric population - A systematic review
    Priyanka
    Kadavigere, Rajagopal
    Sukumar, Suresh
    Pendem, Saikiran
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2021, 17 (04) : 845 - 852
  • [23] A Review of Diagnostic Reference Levels in Computed Tomography
    Dawd, Jemal Edris
    Ozsahin, Dilber Uzun
    Ozsahin, Ilker
    CURRENT MEDICAL IMAGING, 2022, 18 (06) : 623 - 632
  • [24] Analysis of size-specific dose profiles beyond the scan range in water phantoms undergoing computed tomography examinations
    Masoudi, M.
    Faghihi, R.
    Sina, S.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2021, 19 (03): : 551 - 557
  • [25] LOCAL STUDY OF DIAGNOSTIC REFERENCE LEVELS FOR COMPUTED TOMOGRAPHY EXAMINATIONS OF ADULT PATIENTS IN IZMIR, TURKEY
    Yurt, Aysegul
    Ozsoykal, Ismail
    Kandemir, Recep
    Ada, Emel
    RADIATION PROTECTION DOSIMETRY, 2020, 190 (04) : 446 - 451
  • [26] Local diagnostic reference levels for cardiac computed tomography
    Pilat, Wiktoria
    Kidon-Szoltysek, Joanna
    Stasiow, Bartlomiej
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2024, 30 (04):
  • [27] ACCURACY OF SIZE-SPECIFIC DOSE ESTIMATE CALCULATION FROM CENTER SLICE IN COMPUTED TOMOGRAPHY
    Boos, Johannes
    Kroepil, Patric
    Bethge, Oliver Th.
    Aissa, Joel
    Schleich, Christoph
    Sawicki, Lino Morris
    Heinzler, Niklas
    Antoch, Gerald
    Thomas, Christoph
    RADIATION PROTECTION DOSIMETRY, 2018, 178 (01) : 8 - 19
  • [28] A new approach to dose reference levels in pediatric CT: Age and size-specific dose estimation
    Rawashdeh, Mohammad
    Saade, Charbel
    Mousa, Dana S. Al
    Abdelrahman, Mostafa
    Kumar, Praveen
    McEntee, Mark
    RADIATION PHYSICS AND CHEMISTRY, 2023, 205
  • [29] Tailoring CT Dose to Patient Size: Implementation of the Updated 2017 ACR Size-specific Diagnostic Reference Levels
    Klosterkemper, Yan
    Appel, Elisabeth
    Thomas, Christoph
    Bethge, Oliver T.
    Aissa, Joel
    Kroepil, Patric
    Antoch, Gerald
    Boos, Johannes
    ACADEMIC RADIOLOGY, 2018, 25 (12) : 1624 - 1631
  • [30] Diagnostic reference levels and patient doses in computed tomography examinations in Greece
    Simantirakis, G.
    Hourdakis, C. J.
    Economides, S.
    Kaisas, I.
    Kalathaki, M.
    Koukorava, C.
    Manousaridis, G.
    Pafilis, C.
    Tritakis, P.
    Vogiatzi, S.
    Kamenopoulou, V.
    Dimitriou, P.
    RADIATION PROTECTION DOSIMETRY, 2015, 163 (03) : 319 - 324