Femoral neck system and cannulated compression screws in the treatment of non-anatomical reduction Pauwels type-III femoral neck fractures: A finite element analysis

被引:7
作者
Zhong, Zhou [1 ]
Lan, Xuejun [2 ]
Xiang, Zhou [1 ]
Duan, Xin [1 ,3 ]
机构
[1] Sichuan Univ, West China Hosp, Dept Orthoped Surg, 37 Guoxue Lane, Chengdu 610041, Peoples R China
[2] Sichuan Univ, West China Hosp, Dept Hlth Management Ctr, Gen Practice Ctr, 37 Guoxue Lane, Chengdu 610041, Peoples R China
[3] Sichuan Fifth Peoples Hosp, Dept Orthoped Surg, Chengdu 610000, Peoples R China
基金
中国国家自然科学基金;
关键词
Femoral neck fractures; Cannulated compression screws; Femoral neck system; Biomechanics; Finite element analysis; DYNAMIC HIP SCREW; INTERNAL-FIXATION; MANAGEMENT; POSITION; ANGLE; RISK;
D O I
10.1016/j.clinbiomech.2023.106060
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: High shear force is a major factor detrimental to the healing of vertical femoral neck fractures. In addition to firm fixation, reduction quality is crucial for postoperative stability. The present study aimed to compare the biomechanical stability of the newly invented femoral neck system and three inverted-triangle cannulated compression screws treatments for non-anatomical reduction of Pauwels type-III femoral neck fractures. Methods: A total of 18 non-anatomical reduction Pauwels type-III femoral neck fracture finite element models were fabricated and fixed using three inverted-triangle cannulated compression screws or the femoral neck system. A 1950-N force was applied to the femoral head to simulate the physiological load during a single-leg stance. Parameters of the maximum total deformation, the interfragmentary gap, and the maximum von Mises stress of the implants and the proximal femur were analyzed. Findings: The results of the maximum total deformation, interfragmentary gap, and maximum von Mises stress of the implants in the negative-negative buttress model fixed by the femoral neck system were the largest among all groups (3.58 mm, 0.252 mm, and 729.68 MPa, respectively). In contrast, the anatomical-anatomical reduction model fixed by three inverted-triangle cannulated compression screws demonstrated the minimum total deformation, interfragmentary gap, and minimum von Mises stress of implants (1.107 mm, 0.09 mm, and 189.83 MPa, respectively). Interpretation: Anatomical reduction or positive buttress in femoral neck fractures should be recommended during fracture reduction. The femoral neck system showed weaker biomechanical stability than three inverted-triangle cannulated compression screws in treating Pauwels type-III femoral neck fractures.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Modified cannulated screw fixation in the treatment of Pauwels type III femoral neck fractures: A biomechanical study
    Zhou, Lin
    Lin, Jiaming
    Huang, Anfei
    Gan, Weidong
    Zhai, Xu
    Sun, Kai
    Huang, Shiqing
    Li, Zhizhong
    CLINICAL BIOMECHANICS, 2020, 74 : 103 - 110
  • [42] Femoral neck fractures in non-geriatric patients: femoral neck system versus cannulated cancellous screw
    Kenmegne, Guy Romeo
    Zou, Chang
    Fang, Yue
    He, Xuanhong
    Lin, Yixiang
    Yin, Yijie
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [43] Finite element comparative analysis of three different internal fixation methods in the treatment of Pauwels type III femoral neck fractures
    Ma, Ji
    Zhao, Ziying
    Zhi, Xiaodong
    Wang, Hao
    Wang, Wei
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [44] Additional Screw Added to the Femoral Neck System Could Enhance the Stability of Pauwel Type III Femoral Neck Fractures: a Finite Element Analysis
    Cha, Yonghan
    Park, Sunghoon
    Jung, Chang-Ho
    Kim, Jin-Woo
    Yoo, Jun-Il
    Kim, Jung-Taek
    Jeon, Yongho
    Han, Kyeong Jin
    CLINICS IN ORTHOPEDIC SURGERY, 2025, 17 (02) : 204 - 215
  • [45] A Comparative Analysis of Femoral Neck System and Three Cannulated Screws Fixation in the Treatment of Femoral Neck Fractures: A Six-Month Follow-Up
    Zhang, Ya-zhong
    Lin, Yan
    Li, Chao
    Yue, Xi-jun
    Li, Gao-yu
    Wang, Bin
    Wang, Yun-qing
    Zhu, Zi-qiang
    ORTHOPAEDIC SURGERY, 2022, 14 (04) : 686 - 693
  • [46] Femoral neck system vs. cannulated screws on treating femoral neck fracture: a meta-analysis and system review
    Zhou, Yimin
    Li, Zongyang
    Lao, Kecheng
    Wang, Zixiu
    Zhang, Li
    Dai, Shiyou
    Fan, Xiao
    FRONTIERS IN SURGERY, 2023, 10
  • [47] Biomechanical and clinical evaluation of interlocking hip screw in Pauwels III femoral neck fractures: A comparison with inverted triangle cannulated screws
    Zhang, Jian
    Jiang, Haozheng
    Dai, Wei
    Hersi, Salad Abdirahman
    Cheong, John Chun Tien Chui Wan
    Chu, Zhenchen
    Lou, Zhiyuan
    Zhang, Deqiang
    Liu, Changjian
    Tian, Kang
    Tang, Xin
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [48] Novel screw fixation placement configuration for the treatment of Pauwels type III femoral neck fractures: a finite element analysis
    Petra Adamović
    Janoš Kodvanj
    Dejan Blažević
    Srećko Sabalić
    Medical & Biological Engineering & Computing, 2023, 61 : 1005 - 1015
  • [49] Comparison Between Femoral Neck Systems and Cannulated Cancellous Screws in Treating Femoral Neck Fractures: A Meta-Analysis
    Tian, Peng
    Kuang, Lan
    Li, Zhi-jun
    Xu, Gui-jun
    Fu, Xin
    GERIATRIC ORTHOPAEDIC SURGERY & REHABILITATION, 2022, 13
  • [50] Proximal Femoral Locking Plate With Cannulated Screws for the Treatment of Femoral Neck Fractures
    Lin, Dasheng
    Lian, Kejian
    Ding, Zhenqi
    Zhai, Wenliang
    Hong, Jiayuan
    ORTHOPEDICS, 2012, 35 (01) : E1 - E5