Enhancing electric vehicle penetration and grid operation performance in old residential communities through hybrid AC/DC microgrid reconstruction

被引:12
作者
Yu, Hang [1 ,2 ]
Lei, Xiang [2 ]
Niu, Songyan [1 ,2 ]
Shao, Ziyun [3 ]
Jian, Linni [1 ,2 ,4 ]
机构
[1] Southern Univ Sci & Technol, Jiaxing Res Inst, Jiaxing 314000, Peoples R China
[2] Southern Univ Sci & Technol, Dept Elect & Elect Engn, Shenzhen 518055, Peoples R China
[3] Guangzhou Univ, Sch Elect & Commun Engn, Guangzhou 510006, Peoples R China
[4] Southern Univ Sci & Technol, Shenzhen 518055, Peoples R China
关键词
Electric vehicles (EVs); Hybrid AC; DC microgrid; Coordinated operation strategy; System reconstruction; HIERARCHICAL CONTROL; STRATEGY; OPTIMIZATION; LVDC;
D O I
10.1016/j.apenergy.2023.121459
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The widespread popularity of electric vehicles (EVs) imposes great challenges for distribution grids, such as feeder congestion, voltage deviation, and so forth. Although building new electrical facilities is feasible to release more capacity for EV integration, this is not a wise scheme to be applied in old residential communities owing to huge costs and limited spaces. In light of this, the paper proposes an easy-to-implement and cost-effective hybrid AC/DC microgrid reconstruction scheme for low-voltage distribution grids of old residential communities. The advanced power electronic device called smart interlinking unit (SIU) is incorporated in prior power distribution rooms of residential communities, featuring integrated structure, dedicated interfaces, and flexible control capability. The SIU-based architecture reuses existing redundant transformers and power lines to form AC/DC subgrids. An outstanding transfer capacity improvement and power loss reduction via the DC renovation are quantified. Considering the varied efficiency characteristics of multiple power converters and transformers, a hierarchical coordinated operation strategy is proposed for this architecture to realize the overall energy-saving operation. The optimal operation point tracking and AC/DC voltage regulation are included in the strategy design. Regarding the target scenario in the case study, the adopted reconstruction scheme would achieve a significant 297% of the maximum EV penetration. The real-time voltage regulation for AC and DC feeders is also realized to avoid possible voltage violations. Additionally, the proposed architecture and operation strategy could obtain about 10% of load ratio improvement and 1.5% of average efficiency promotion compared to the traditional AC architecture.
引用
收藏
页数:15
相关论文
共 2 条
  • [1] Enhancing Microgrid Operation Through Electric Vehicle Integration: A Survey
    Sora, James
    Serban, Ioan
    Petreus, Dorin
    IEEE ACCESS, 2024, 12 : 64897 - 64912
  • [2] Enhancing the Dynamic Performance of Hybrid Photovoltaic-Battery DC Microgrid Through Piece-Wise Affine Model-Based Controller With Mode Transition Function
    Dwiono, Wakhyu
    Trilaksono, Bambang Riyanto
    Rachmildha, Tri Desmana
    Rizqiawan, Arwindra
    IEEE ACCESS, 2024, 12 : 169910 - 169927