Off-design performance and control strategies of sCO2 recompression power systems considering compressor operating safety

被引:8
作者
Chang, Zhiyuan [1 ]
Zhao, Yu [1 ]
Zhao, Yuanyang [1 ]
Liu, Guangbin [1 ]
Yang, Qichao [1 ]
Li, Liansheng [1 ]
机构
[1] Qingdao Univ Sci & Technol, Coll Electromech Engn, Qingdao 266061, Peoples R China
基金
中国国家自然科学基金;
关键词
Compressor; Control strategy; Off-design working condition; supercritical CO 2 cycle; Turbine; SUPERCRITICAL CO2 RECOMPRESSION; THERMODYNAMIC ANALYSIS; EXERGOECONOMIC ANALYSES; CARBON-DIOXIDE; GAS-TURBINE; CYCLE; EXERGY; ENERGY; OPTIMIZATION; RECOVERY;
D O I
10.1016/j.applthermaleng.2023.121044
中图分类号
O414.1 [热力学];
学科分类号
摘要
The supercritical carbon dioxide (sCO2) power cycle is a promising power cycle in the field of thermal power generation. The system is often operated under off-design conditions, which would lead to the unsafe or unstable operation of the sCO2 power system. The performance of the sCO2 recompression cycle system under off-design working conditions by different control strategies is investigated in this paper. A one-dimensional design prediction model for centrifugal compressors is introduced to predict off-design system performance and the operating conditions and safety of centrifugal compressors under the 5 control strategies are simulated and compared. To show the difference between the control strategies, the thermal efficiency was compared, the highest thermal efficiency of the system is 11.2 % by the inventory control method, and the lowest thermal efficiency is 5.45 % by the turbine bypass control method. The compressor backflow control method makes the main compressor has a choking risk and the recompressor has a surging risk when the output power of the system is small. The speed variations of centrifugal compressors are 39.55 % (MC) and 34.71 % (RC) using the inventory control method. A hybrid control strategy (the compressor backflow and inventory control strategies) is proposed based on the performance maps of centrifugal compressors. The turbine efficiency is improved by 4.5 % and the system thermal efficiency is improved by 7.1 % by using the hybrid control strategy. The hybrid control strategy can solve the problem of dangerous working conditions of centrifugal compressors. The results of this study can guide the system control and operational safety of sCO2 recompression cycles.
引用
收藏
页数:21
相关论文
共 76 条
  • [1] Generation-IV nuclear power: A review of the state of the science
    Abram, Tim
    Ion, Sue
    [J]. ENERGY POLICY, 2008, 36 (12) : 4323 - 4330
  • [2] REVIEW OF SUPERCRITICAL CO2 POWER CYCLE TECHNOLOGY AND CURRENT STATUS OF RESEARCH AND DEVELOPMENT
    Ahn, Yoonhan
    Bae, Seong Jun
    Kim, Minseok
    Cho, Seong Kuk
    Baik, Seungjoon
    Lee, Jeong Ik
    Cha, Jae Eun
    [J]. NUCLEAR ENGINEERING AND TECHNOLOGY, 2015, 47 (06) : 647 - 661
  • [3] sCO2 power plants for waste heat recovery: design optimization and part-load operation strategies
    Alfani, Dario
    Binotti, Marco
    Macchi, Ennio
    Silva, Paolo
    Astolfi, Marco
    [J]. APPLIED THERMAL ENGINEERING, 2021, 195
  • [4] CARBON DIOXIDE CONDENSATION CYCLES FOR POWER PRODUCTION
    ANGELINO, G
    [J]. JOURNAL OF ENGINEERING FOR POWER, 1968, 90 (03): : 287 - &
  • [5] Ashcroft JA, 2009, SUP CO2 POW CYCL S, P29
  • [6] Aungier R.H., 2000, CENTRIFUGAL COMPRESS
  • [7] The Modeling of Coal-related CO2 Emissions and Projections into Future Planning
    Aydin, G.
    [J]. ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2014, 36 (02) : 191 - 201
  • [8] Balje O.E., 1981, Turbomachines (A Guide to Design, Selection, and Theory)
  • [9] FLOW LOSSES IN ABRUPT ENLARGEMENTS AND CONTRACTIONS
    BENEDICT, RP
    CARLUCCI, NA
    SWETZ, SD
    [J]. JOURNAL OF ENGINEERING FOR POWER, 1966, 88 (01): : 73 - &
  • [10] Brenes B.M., Design of supercritical carbon dioxide centrifugal compressors, P165