X-ray fluorescence mapping (XRF) is a highly efficient and non-invasive technique for quantifying material composition with micro and nanoscale spatial resolutions. Quantitative XRF analysis, however, confronts challenges from the long-lasting problem called self-absorption. Moreover, correcting two-dimensional XRF mapping datasets is particularly difficult because it is an ill-posed inverse problem. Here we report a semi-empirical method that can effectively correct 2D XRF mapping data. The correction error is generally less than 10% from a comprehensive evaluation of the accuracy in various configurations. The proposed method was applied to quantify the composition distribution around the grain boundaries in an electrochemically corroded stainless steel sample. Highly localized Cr enrichment was found around the crack sites, which was invisible before the absorption correction.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Metal Artifact Reduction Based on Beam Hardening Correction and Statistical Iterative Reconstruction for X-ray Computed Tomography
    Zhang, Yanbo
    Mou, Xuanqin
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [42] Low-dose x-ray phase-contrast and absorption CT using equally sloped tomography
    Fahimian, Benjamin P.
    Mao, Yu
    Cloetens, Peter
    Miao, Jianwei
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (18) : 5383 - 5400
  • [43] Digital X-Ray 3D-Microtomograph for Testing Materials and Components Used in Electronics
    Syryamkin, V. I.
    RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING, 2016, 52 (09) : 504 - 511
  • [44] Digital X-ray 3D-microtomograph for testing materials and components used in electronics
    V. I. Syryamkin
    Russian Journal of Nondestructive Testing, 2016, 52 : 504 - 511
  • [45] Model-Based 3-D X-Ray Induced Acoustic Computerized Tomography
    Pandey, Prabodh Kumar
    Wang, Siqi
    Sun, Leshan
    Xing, Lei
    Xiang, Liangzhong
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2023, 7 (05) : 532 - 543
  • [46] Improvement in methodology for testing iterative reconstruction algorithms in 3D X-ray tomography
    Donaire, JG
    García, I
    IMAGING SCIENCE JOURNAL, 2005, 53 (04) : 214 - 225
  • [47] Fast 3D reconstruction method for differential phase contrast X-ray CT
    McCann, Michael T.
    Nilchian, Masih
    Stampanoni, Marco
    Unser, Michael
    OPTICS EXPRESS, 2016, 24 (13): : 14564 - 14581
  • [48] Fluorescence background subtraction technique for hybrid fluorescence molecular tomography/x-ray computed tomography imaging of a mouse model of early stage lung cancer
    Ale, Angelique
    Ermolayev, Vladimir
    Deliolanis, Nikolaos C.
    Ntziachristos, Vasilis
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (05)
  • [49] Imaging Experiment of Multi-Pinhole Based X-Ray Fluorescence Computed Tomography Using Rat Head Phantoms
    Sasaya, Tenta
    Oouchi, Tsuyoshi
    Yuasa, Tetsuya
    Seo, Seung-Jun
    Jeon, Jae-Geun
    Kim, Jong-Ki
    Sunaguchi, Naoki
    Hyodo, Kazuyuki
    Zeniya, Tsutomu
    2019 27TH EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO), 2019,
  • [50] 3-D Inspection Method for Industrial Product Assembly Based on Single X-Ray Projections
    Li, Xuan
    Wang, Sukai
    Chen, Ping
    Wang, Liming
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70