Self-absorption correction on 2D X-ray fluorescence maps

被引:0
|
作者
Ge, Mingyuan [1 ]
Yan, Hanfei [1 ]
Huang, Xiaojing [1 ]
Chu, Yong S. [1 ]
机构
[1] Brookhaven Natl Lab, Natl Synchrotron Light Source 2, Upton, NY 11973 USA
关键词
IMAGE-RECONSTRUCTION;
D O I
10.1038/s41598-023-33383-w
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
X-ray fluorescence mapping (XRF) is a highly efficient and non-invasive technique for quantifying material composition with micro and nanoscale spatial resolutions. Quantitative XRF analysis, however, confronts challenges from the long-lasting problem called self-absorption. Moreover, correcting two-dimensional XRF mapping datasets is particularly difficult because it is an ill-posed inverse problem. Here we report a semi-empirical method that can effectively correct 2D XRF mapping data. The correction error is generally less than 10% from a comprehensive evaluation of the accuracy in various configurations. The proposed method was applied to quantify the composition distribution around the grain boundaries in an electrochemically corroded stainless steel sample. Highly localized Cr enrichment was found around the crack sites, which was invisible before the absorption correction.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] X-ray fluorescence computed tomography with absorption correction for biomedical samples
    Yang, Qun
    Deng, Biao
    Du, Guohao
    Xie, Honglan
    Zhou, Guangzhao
    Xiao, Tiqiao
    Xu, Hongjie
    X-RAY SPECTROMETRY, 2014, 43 (05) : 278 - 285
  • [2] A 2D multiresolution image reconstruction method in X-ray computed tomography
    Costin, Marius
    Lazaro-Ponthus, Delphine
    Legoupil, Samuel
    Duvauchelle, Philippe
    Kaftandjian, Valerie
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2011, 19 (02) : 229 - 247
  • [3] PARTIAL INVERSION OF THE 2D ATTENUATED X-RAY TRANSFORM WITH DATA ON AN ARC
    Fujiwara, Hiroshi
    Sadiq, Kamran
    Tamasan, Alexandru
    INVERSE PROBLEMS AND IMAGING, 2022, 16 (01) : 215 - 228
  • [4] Quantitative X-ray fluorescence computed tomography for low-Z samples using an iterative absorption correction algorithm
    Huang, Rong
    Limburg, Karin
    Rohtla, Mehis
    AIP ADVANCES, 2017, 7 (05):
  • [5] Penalized-likelihood image reconstruction for x-ray fluorescence computed tomography with unknown fluorescence attenuation maps
    La Rivière, PJ
    Billmire, DM
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IV, 2004, 5535 : 243 - 252
  • [6] Image quality models for 2D and 3D x-ray imaging systems: A perspective vignette
    Siewerdsen, Jeffrey H. H.
    MEDICAL PHYSICS, 2023, 50 (S1) : 109 - 116
  • [7] Accelerating X-ray Fluorescence Computed Tomography
    La Riviere, P. J.
    Vargas, P.
    Fu, G.
    Meng, L. J.
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 1000 - +
  • [8] Proton Beam X-Ray Fluorescence CT
    Bazalova, M.
    Ahmad, M.
    Fahrig, R.
    Xing, L.
    MEDICAL PHYSICS, 2014, 41 (06) : 449 - 449
  • [9] High spatial resolution x-ray luminescence computed tomography and x-ray fluorescence computed tomography
    Dai, Xianjin
    Sivasubramanian, Kathyayini
    Xing, Lei
    MOLECULAR-GUIDED SURGERY: MOLECULES, DEVICES, AND APPLICATIONS V, 2019, 10862
  • [10] X-ray Fluorescence Computed Tomography (XFCT) Imaging with a Superfine Pencil Beam X-ray Source
    Romero, Ignacio O.
    Fang, Yile
    Lun, Michael
    Li, Changqing
    PHOTONICS, 2021, 8 (07)