Electrocardiographic markers of subclinical atrial fibrillation detected by implantable loop recorder: insights from the LOOP Study

被引:8
作者
Xing, Lucas Yixi [1 ,2 ]
Diederichsen, Soren Zoga [1 ,3 ]
Hojberg, Soren [3 ]
Krieger, Derk W. [4 ,5 ]
Graff, Claus [6 ]
Olesen, Morten S. [1 ,7 ]
Nielsen, Jonas Bille [1 ]
Brandes, Axel [8 ,9 ,10 ]
Kober, Lars [1 ,11 ]
Haugan, Ketil Jorgen [2 ]
Svendsen, Jesper Hastrup [1 ,11 ]
机构
[1] Copenhagen Univ Hosp, Rigshosp, Dept Cardiol, Inge Lehmanns Vej 7, DK-2100 Copenhagen, Denmark
[2] Zealand Univ Hosp Roskilde, Dept Cardiol, DK-4000 Roskilde, Denmark
[3] Copenhagen Univ Hosp, Bispebjerg Hosp, Dept Cardiol, DK-2400 Copenhagen, Denmark
[4] Mediclin City Hosp, Dept Neurol, Dubai, U Arab Emirates
[5] Mohammed Bin Rashid Univ Med & Hlth Sci, Dept Neurosci, Dubai, U Arab Emirates
[6] Aalborg Univ, Dept Hlth Sci & Technol, DK-9220 Aalborg, Denmark
[7] Univ Copenhagen, Fac Hlth & Med Sci, Dept Biomed Sci, DK-2200 Copenhagen, Denmark
[8] Univ Southern Denmark, Fac Hlth Sci, Dept Clin Res, DK-5000 Odense, Denmark
[9] Odense Univ Hosp, Dept Cardiol, DK-5000 Odense, Denmark
[10] Univ Hosp Southern Denmark Esbjerg, Dept Cardiol, DK-6700 Esbjerg, Denmark
[11] Univ Copenhagen, Fac Hlth & Med Sci, Dept Clin Med, DK-2200 Copenhagen, Denmark
来源
EUROPACE | 2023年 / 25卷 / 05期
基金
欧盟地平线“2020”;
关键词
Atrial fibrillation; Electrocardiography; P-wave; Cardiac arrhythmias; Stroke; PR INTERVAL; RISK; DURATION; INDIVIDUALS; ASSOCIATION;
D O I
10.1093/europace/euad014
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Insights into subclinical atrial fibrillation (AF) development are warranted to inform the strategies of screening and subsequent clinical management upon AF detection. Hence, this study sought to characterize the onset and progression of subclinical AF with respect to 12-lead electrocardiogram (ECG) parameters. Methods and results We included AF-naive individuals aged 70-90 years with additional stroke risk factors who underwent implantable loop recorder (ILR) monitoring in the LOOP Study. Using data from daily ILR recordings and the computerized analysis of baseline ECG, we studied empirically selected ECG parameters for AF detection (>= 6 min), cumulative AF burden, long-lasting AF (>= 24 h), and AF progression. Of 1370 individuals included, 419 (30.6%) developed AF during follow-up, with a mean cumulative AF burden of 1.5% [95% CI: 1.2-1.8]. Several P-wave-related and ventricular ECG parameters were associated with new-onset AF and with cumulative AF burden in AF patients. P-wave duration (PWD), P-wave terminal force in Lead V-1, and interatrial block (IAB) further demonstrated significant associations with long-lasting AF. Among AF patients, we observed an overall reduction in cumulative AF burden over time (IRR 0.70 [95% CI: 0.51-0.96]), whereas IAB was related to an increased risk of progression to AF >= 24 h (HR 1.86 [95% CI: 1.02-3.39]). Further spline analysis also revealed longer PWD to be associated with this progression in AF duration. Conclusion We identified several ECG parameters associated with new-onset subclinical AF detected by ILR. Especially PWD and IAB were robustly related to the onset and the burden of AF as well as progression over time.
引用
收藏
页数:10
相关论文
共 50 条
[31]   Long-term ECG monitoring using an implantable loop recorder for the detection of atrial fibrillation after cavotricuspid isthmus ablation in patients with atrial flutter [J].
Mittal, Suneet ;
Pokushalov, Evgeny ;
Romanov, Alexander ;
Ferrara, Martha ;
Arshad, Aysha ;
Musat, Dan ;
Preminger, Mark ;
Sichrovsky, Tina ;
Steinberg, Jonathan S. .
HEART RHYTHM, 2013, 10 (11) :1598-1604
[32]   Global Results of Implantable Loop Recorder for Detection of Atrial Fibrillation After Stroke: Reveal LINQ Registry [J].
Toyoda, Kazunori ;
Kusano, Kengo ;
Iguchi, Yasuyuki ;
Ikeda, Takanori ;
Morishima, Itsuro ;
Tomita, Hirofumi ;
Asano, Taku ;
Yamane, Teiichi ;
Nakahara, Ichiro ;
Watanabe, Eiichi ;
Koyama, Junjiroh ;
Kato, Ritsushi ;
Morita, Hiroshi ;
Hirano, Teruyuki ;
Soejima, Kyoko ;
Owada, Shingen ;
Abe, Haruhiko ;
Yasaka, Masahiro ;
Nakamura, Toshihiro ;
Kasner, Scott ;
Natale, Andrea ;
Beinart, Sean ;
Amin, Alpesh N. ;
Pouliot, Erika ;
Franco, Noreli ;
Hidaka, Kazuhiro ;
Okumura, Ken .
JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2024, 13 (21)
[33]   Implantable loop recorder monitoring after concomitant surgical ablation for atrial fibrillation (AF): insights from more than 200 continuously monitored patients [J].
Simon Pecha ;
Muhammet Ali Aydin ;
Teymour Ahmadzade ;
Friederike Hartel ;
Boris Hoffmann ;
Daniel Steven ;
Stephan Willems ;
Hermann Reichenspurner ;
Florian Mathias Wagner .
Heart and Vessels, 2016, 31 :1347-1353
[34]   Implantable loop recorder monitoring after concomitant surgical ablation for atrial fibrillation (AF): insights from more than 200 continuously monitored patients [J].
Pecha, Simon ;
Aydin, Muhammet Ali ;
Ahmadzade, Teymour ;
Hartel, Friederike ;
Hoffmann, Boris ;
Steven, Daniel ;
Willems, Stephan ;
Reichenspurner, Hermann ;
Wagner, Florian Mathias .
HEART AND VESSELS, 2016, 31 (08) :1347-1353
[35]   Effectiveness of implantable loop recorder and Hotter electrocardiographic monitoring for the detection of arrhythmias in patients with peripartum cardiomyopathy [J].
Hoevelmann, Julian ;
Sliwa, Karen ;
Briton, Olivia ;
Ntsekhe, Mpiko ;
Chin, Ashley ;
Viljoen, Charle .
CLINICAL RESEARCH IN CARDIOLOGY, 2023, 112 (03) :379-391
[36]   Detection of atrial fibrillation with implantable loop recorders in horses [J].
Buhl, Rikke ;
Hesselkilde, Eva M. ;
Carstensen, Helena ;
Fenner, Merle F. ;
Jespersen, Thomas ;
Tfelt-Hansen, Jacob ;
Michael Sattler, Stefan .
EQUINE VETERINARY JOURNAL, 2021, 53 (02) :397-403
[37]   Left atrial volume and function assessed by cardiac magnetic resonance imaging are markers of subclinical atrial fibrillation as detected by continuous monitoring [J].
Bertelsen, Litten ;
Diederichsen, Soren Zoga ;
Haugan, Ketil Jorgen ;
Brandes, Axel ;
Graff, Claus ;
Krieger, Derk ;
Kronborg, Christian ;
Kober, Lars ;
Hojberg, Soren ;
Vejlstrup, Niels ;
Svendsen, Jesper Hastrup .
EUROPACE, 2020, 22 (05) :724-731
[38]   Implantable loop recorder in Brugada syndrome: Insights from a single-center experience [J].
Arabia, Gianmarco ;
Cerini, Manuel ;
Cersosimo, Angelica ;
Vinciguerra, Paolo ;
Calvi, Emiliano ;
Mitacchione, Gianfranco ;
Aboelhassan, Mohamed ;
Giacopelli, Daniele ;
Curnis, Antonio .
IJC HEART & VASCULATURE, 2024, 51
[39]   Atrial Fibrillation Detection in Patients With an Implantable Loop Recorder After Acute Embolic Stroke of Unknown Source (ESUS) [J].
Kitsiou, Alkisti ;
Kalyani, Malik ;
Ejangue, Ekosso Lucy ;
Hagemeister, Christoph ;
Manegold, Johannes ;
Israel, Carsten ;
Schaebitz, Wolf-Ruediger .
STROKE, 2016, 47
[40]   Implantable Loop Recorder Monitoring is Useful in Detecting a High Incidence of Previously Unrecognized Atrial Fibrillation in Hemodialysis Patients. Preliminary Data From the Monitoring in Dialysis (MiD) Study [J].
Koplan, Bruce A. ;
Tombul, Selcuk A. ;
Tumlin, James A. ;
Charytan, David M. .
CIRCULATION, 2014, 130