Optimal Placement of Phasor Measurement Unit in Smart Grids Considering Multiple Constraints

被引:4
|
作者
Chen, Tengpeng [1 ,2 ]
Ren, He [1 ]
Sun, Yuhao [3 ]
Kraft, Markus [4 ,5 ,6 ]
Amaratunga, Gehan A. J. [7 ]
机构
[1] Xiamen Univ, Dept Instrumental & Elect Engn, Xiamen, Peoples R China
[2] Shenzhen Res Inst Xiamen Univ, Shenzhen, Peoples R China
[3] CTC Intelligence Shenzhen Technol Co Ltd, Shenzhen, Peoples R China
[4] Univ Cambridge, Dept Chem Engn & Biotechnol, Cambridge, England
[5] Cambridge Ctr Adv Res & Educ Singapore, CREATE Tower, Singapore, Singapore
[6] Nanyang Technol Univ, Sch Chem & Biomed Engn, Singapore, Singapore
[7] Univ Cambridge, Dept Engn, Cambridge, England
基金
中国国家自然科学基金; 新加坡国家研究基金会;
关键词
Phasor measurement units; State estimation; Noise measurement; Loss measurement; Power systems; Maximum likelihood estimation; Observability; Phasor measurement unit (PMU); smart grids; optimal placement; state estimation (SE); OPTIMAL PMU PLACEMENT; ROBUST STATE ESTIMATION; CHANNEL CAPACITY; SYSTEM; WAMS; ALGORITHM;
D O I
10.35833/MPCE.2022.000003
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The distribution of measurement noise is usually assumed to be Gaussian in the optimal phasor measurement unit (PMU) placement (OPP) problem. However, this is not always accurate in practice. This paper proposes a new OPP method for smart grids in which the effects of conventional measurements, limited channels of PMUs, zero-injection buses (ZIBs), single PMU loss contingency, state estimation error (SEE), and the maximum SEE variance (MSEEV) are considered. The SEE and MSEEV are both obtained using a robust t-distribution maximum likelihood estimator (MLE) because t-distribution is more flexible for modeling both Gaussian and non-Gaussian noises. The A-and G-optimal experimental criteria are utilized to form the SEE and MSEEV constraints. This allows the optimization problem to be converted into a linear objective func- tion subject to linear matrix inequality observability con- straints. The performance of the proposed OPP method is verified by the simulations of the IEEE 14-bus, 30-bus, and 118-bus systems as well as the 211-bus practical distribution system in China.
引用
收藏
页码:479 / 488
页数:10
相关论文
共 50 条
  • [41] Phasor Measurement Units Optimal Placement and Performance Limits for Fault Localization
    Jamei, Mahdi
    Ramakrishna, Raksha
    Tesfay, Teklemariam
    Gentz, Reinhard
    Roberts, Ciaran
    Scaglione, Anna
    Peisert, Sean
    IEEE JOURNAL ON SELECTED AREAS IN COMMUNICATIONS, 2020, 38 (01) : 180 - 192
  • [42] Accurate Fault Detection Of Distribution Network With Optimal Placement of Phasor Measurement Unit
    Ray, Papia
    Beura, Subal
    PROCEEDINGS OF THE 2019 INTERNATIONAL CONFERENCE ON INTELLIGENT SUSTAINABLE SYSTEMS (ICISS 2019), 2019, : 76 - 81
  • [43] Genetic algorithm-based phasor measurement unit placement method considering observability and security criteria
    Mueller, Heloisa H.
    Castro, Carlos A.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2016, 10 (01) : 270 - 280
  • [44] Optimal phasor measurement unit placement for numerical observability in the presence of conventional measurements using semi-definite programming
    Korres, George N.
    Manousakis, Nikolaos M.
    Xygkis, Themistoklis C.
    Lofberg, Johan
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2015, 9 (15) : 2427 - 2436
  • [45] On Phasor Measurement Unit Placement against State and Topology Attacks
    Kim, Jinsub
    Tong, Lang
    2013 IEEE INTERNATIONAL CONFERENCE ON SMART GRID COMMUNICATIONS (SMARTGRIDCOMM), 2013, : 396 - 401
  • [46] Phasor measurement unit placement techniques for complete and incomplete observability
    Nuqui, RF
    Phadke, AG
    IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (04) : 2381 - 2388
  • [47] Empowering grid intelligence: a comprehensive review on optimal placement and diverse applications of synchronized phasor measurement units in modern power systems
    Sneha, Boya
    Babu, Rohit
    Mahapatra, Sheila
    INTERNATIONAL JOURNAL OF SYSTEM ASSURANCE ENGINEERING AND MANAGEMENT, 2025, 16 (02) : 622 - 650
  • [48] Optimal placement of Phasor Measurement Unit considering System Observability Redundancy Index: case study of the Kenya power transmission network
    Okendo, Edwin Otieno
    Wekesa, Cyrus Wabuge
    Saulo, Michael Juma
    HELIYON, 2021, 7 (07)
  • [49] An investment decision model for the optimal placement of phasor measurement units
    Mousavian, Seyedamirabbas
    Feizollahi, Mohammad Javad
    EXPERT SYSTEMS WITH APPLICATIONS, 2015, 42 (21) : 7276 - 7284
  • [50] Optimal Placement of Phasor Measurement Units for Transmission Grid Observability
    Shafiullah, Md
    Rana, Md Juel
    Alam, Md Shafiul
    Uddin, Muhammad Athar
    2016 INTERNATIONAL CONFERENCE ON INNOVATIONS IN SCIENCE, ENGINEERING AND TECHNOLOGY (ICISET 2016), 2016,