Removal of Cd(II), Co(II), Cr(III), Ni(II), Pb(II) and Zn(II) ions from wastewater using polyethyleneimine (PEI) cryogels

被引:28
作者
Bagdat, Sema [1 ]
Tokay, Feyzullah [1 ,2 ]
Demirci, Sahin [2 ,3 ]
Yilmaz, Selehattin [2 ]
Sahiner, Nurettin [2 ,3 ,4 ]
机构
[1] Balikesir Univ, Fac Sci, Chem Dept, TR-10145 Balikesir, Turkiye
[2] Canakkale Onsekiz Mart Univ, Fac Sci, Dept Chem, Terzioglu Campus, TR-17100 Canakkale, Turkiye
[3] Canakkale Onsekiz Mart Univ, Nanosci & Technol Res & Applicat Ctr, Terzioglu Campus, TR-17100 Canakkale, Turkiye
[4] Univ S Florida, Dept Chem & Biomol Engn, Tampa, FL 33620 USA
关键词
Cryogel; Macro porous adsorbent; Heavy metal ion removal; Adsorption; Wastewater treatment; POLY(VINYL ALCOHOL)/HYDROXYAPATITE CRYOGELS; CADMIUM SORPTION PROPERTIES; ADSORBENTS; PERFORMANCE; ADSORPTION; ACID;
D O I
10.1016/j.jenvman.2022.117002
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The removal of the target analytes, Cd(II), Co(II), Cr(III), Ni(II), Pb(II), and Zn(II) from contaminated waters was achieved using super porous polyethyleneimine (PEI) cryogels as adsorbent. The optimum values of the sample pH and contact time were determined as 4.0 and 90 min, respectively, for the removal of the analytes. The adsorption capacities of the sorbent were between 19.88 and 24.39 mgg- 1 from 10 mL of 50 mgL-1 target metal ion solutions. The sorption kinetics of metal ions were fitted with the pseudo-second-order model. The adsorption isotherms of the target analytes into PEI cryogel were well-fitted to the Langmuir isotherm model as expected from the material homogeneity. The selectivity of the PEI cryogel in the presence of Na+, Ca2+, Mg2+, NO3-, K+ and Cl- ions even at high concentrations was tested, and the tolerance limits were satisfactory enough, e.g., the adsorption of the target analytes was even not affected in the presence of 2000 mgL-1 Ca2+, K+, Na+, Cl- and 5000 mgL-1 NO3- ions. The PEI cryogels were successfully utilized in different industrial wastewater samples that were spiked with a known amount of analytes. The removal of the analytes from wastewater samples was in the following ranges 91.94-99.86% for Cd(II), 89.59-99.89% for Co(II), 80.35-99.76% for Cr(III), 92.02-99.84% for Ni(II), 83.28-99.86% for Pb(II), and 82.94-98.24% for Zn(II), respectively. The presented novel removal strategy offers a selective, efficient, and easy application for target metal ions from industrial wastewater samples.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Preconcentration of Fe(III), Co(II), Ni(II), Cu(II), Zn(II) and Pb(II) with ethylenediamine-modified graphene oxide
    Zawisza, Beata
    Baranik, Anna
    Malicka, Ewa
    Talik, Ewa
    Sitko, Rafal
    MICROCHIMICA ACTA, 2016, 183 (01) : 231 - 240
  • [22] Effect of sorption on Co (II), Cu (II), Ni (II) and Zn(II) ions precipitation
    Safdar, M.
    Mustafa, S.
    Naeem, A.
    Mahmood, T.
    Waseem, M.
    Tasleem, S.
    Ahmad, T.
    Siddique, M. T.
    DESALINATION, 2011, 266 (1-3) : 171 - 174
  • [23] ADSORPTION BEHAVIOR OF Pb(II), Zn(II), Cd(II) AND Cr(VI) BY MODIFIED ZEOLITE AND BENTONITE
    Kan, Lili
    Shi, Ruoxin
    Shi, Huisheng
    FRESENIUS ENVIRONMENTAL BULLETIN, 2019, 28 (11A): : 8349 - 8356
  • [24] Silica/carbon dot nanosorbent for the detection and removal of Pb(II) and Co(II) ions from wastewater
    Ryabchenko, Egor O.
    Suslov, Arseniy P.
    Morozov, Nikita A.
    Krivoshapkina, Elena F.
    CHEMICAL ENGINEERING JOURNAL, 2024, 500
  • [25] Removal of Pb(II) and Ni(II) ions from aqueous solution by peat
    Sutcu, Hale
    FRESENIUS ENVIRONMENTAL BULLETIN, 2007, 16 (12A): : 1551 - 1555
  • [26] Enhanced removal of Pb(II), Zn(II) and Cd(II) ions by insolubilized humic acid: Characterization and sorption behaviors
    Alnasra, O. A.
    Khalili, F. I.
    Alhnafat, F. A.
    DESALINATION AND WATER TREATMENT, 2024, 320
  • [27] Removal of Cu(II), Cd(II) and Cr(III) ions from aqueous solution by dam silt
    Ouadjenia-Marouf, Fatima
    Marouf, Reda
    Schott, Jacques
    Yahiaoui, Ahmed
    ARABIAN JOURNAL OF CHEMISTRY, 2013, 6 (04) : 401 - 406
  • [28] Amino-functionalized graphene oxide for Cr(VI Cu(II), Pb(II) and Cd(II) removal from industrial wastewater
    Huang, Huayu
    Wang, Yang
    Zhang, Yubin
    Niu, Zhiying
    Li, Xinli
    OPEN CHEMISTRY, 2020, 18 (01): : 97 - 107
  • [29] Long-term effect of heavy metals Cr(III), Zn(II), Cd(II), Cu(II), Ni(II), Pb(II) on the anammox process performance
    Gutwinski, Piotr
    Cema, Grzegorz
    Ziembinska-Buczynska, Aleksandra
    Wyszynska, Karolina
    Surmacz-Gorska, Joanna
    JOURNAL OF WATER PROCESS ENGINEERING, 2021, 39
  • [30] Study of Ni(II), Cu(II), Pb(II), and Zn(II) Removal Using Sludge and Minerals Followed by MF/UF
    Malamis, Simos
    Katsou, Evina
    Haralambous, Katherine J.
    WATER AIR AND SOIL POLLUTION, 2011, 218 (1-4) : 81 - 92