Development of Molecular Magnetic Resonance Imaging Tools for Longitudinal Tracking of Carotid Atherosclerotic Disease Using Fast Imaging with Steady-State Precession

被引:1
|
作者
Park, Sung-Jin [1 ]
Chan, Wan Ying [2 ]
Ng, Michael [1 ]
Chung, Yiu Cho [3 ]
Chong, Tze Tec [4 ]
Bhakoo, Kishore [5 ]
Chan, Joyce M. S. [1 ,4 ,6 ]
机构
[1] ASTAR, Inst Bioengn & Bioimaging IBB, Translat Cardiovasc Imaging Grp, Singapore, Singapore
[2] Natl Canc Ctr, Div Oncol Imaging, Singapore, Singapore
[3] Siemens Healthcare Pte Ltd, Singapore, Singapore
[4] SingHealth, Singapore Gen Hosp, Dept Vasc Surg, Singapore, Singapore
[5] ASTAR, Inst Bioengn & Bioimaging IBB, Singapore, Singapore
[6] Nanyang Technol Univ, Lee Kong Chian Sch Med, Singapore, Singapore
关键词
Vulnerable carotid plaque; Stroke; Atherosclerosis; Fast imaging with steady-state precession (FISP); Iron; Magnetic resonance imaging (MRI); Inflammation; PLAQUE INFLAMMATION; IRON-OXIDE; ATHEROMA;
D O I
10.1007/s12975-022-01067-8
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Identification of patients with high-risk asymptomatic carotid plaques remains a challenging but essential step in stroke prevention. Current selection criteria for intervention in carotid disease are still determined by symptomatology and degree of luminal stenosis. This strategy has been less effective in identifying the high-risk asymptomatic individual patients. Inflammation is the key factor that drives plaque instability causing clinical sequelae. Currently, there is no imaging tool in routine clinical practice to assess the inflammatory status within atherosclerotic plaques. Herein we describe the development of a novel molecular magnetic resonance imaging (MRI) strategy to interrogate plaque inflammation, and hence its vulnerability in vivo, using dual-targeted iron particle-based probes and fast imaging with steady-state precession (FISP) sequence, adding further prognostic information to luminal stenosis alone. A periarterial cuff was used to generate high-risk plaques at specific timepoints and location of the carotid artery in an apolipoprotein-E-deficient mouse model. Using this platform, we demonstrated that in vivo dual-targeted iron particles with enhanced FISP can (i) target and characterise high-risk vulnerable plaques and (ii) quantitatively report and track the inflammatory activity within carotid plaques longitudinally. This molecular imaging tool may permit (i) accurate monitoring of the risk of carotid plaques and (ii) timely identification of high-risk asymptomatic patients for prophylactic carotid intervention, achieving early stroke prevention.
引用
收藏
页码:357 / 363
页数:7
相关论文
共 44 条
  • [21] Characterization of Carotid Atherosclerotic Plaques Using 3-Dimensional MERGE Magnetic Resonance Imaging and Correlation With Stroke Risk Factors
    Murata, Kiyoko
    Murata, Nozomu
    Chu, Baocheng
    Watase, Hiroko
    Hippe, Daniel S.
    Balu, Niranjan
    Sun, Jie
    Zhao, Xihai
    Hatsukami, Thomas S.
    Yuan, Chun
    STROKE, 2020, 51 (02) : 475 - 480
  • [22] Comparison of carotid atherosclerotic plaque characteristics between symptomatic patients with transient ischemic attack and stroke using high-resolution magnetic resonance imaging
    Lu, Mingming
    Zhang, Lichen
    Yuan, Fei
    Peng, Peng
    Zhang, Hongtao
    Liu, Shitong
    He, Yao
    Cai, Jianming
    Zhao, Xihai
    BMC CARDIOVASCULAR DISORDERS, 2022, 22 (01)
  • [23] Comparison of carotid atherosclerotic plaque characteristics between symptomatic patients with transient ischemic attack and stroke using high-resolution magnetic resonance imaging
    Mingming Lu
    Lichen Zhang
    Fei Yuan
    Peng Peng
    Hongtao Zhang
    Shitong Liu
    Yao He
    Jianming Cai
    Xihai Zhao
    BMC Cardiovascular Disorders, 22
  • [24] Association between Biomechanical Structural Stresses of Atherosclerotic Carotid Plaques and Subsequent Ischaemic Cerebrovascular Events - A Longitudinal in Vivo Magnetic Resonance Imaging-based Finite element Study
    Sadat, U.
    Teng, Z.
    Young, V. E.
    Walsh, S. R.
    Li, Z. Y.
    Graves, M. J.
    Varty, K.
    Gillard, J. H.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2010, 40 (04) : 485 - 491
  • [25] Fiber tracking using magnetic resonance diffusion tensor imaging and its applications to human brain development
    Watts, R
    Liston, C
    Niogi, S
    Ulug, AM
    MENTAL RETARDATION AND DEVELOPMENTAL DISABILITIES RESEARCH REVIEWS, 2003, 9 (03): : 168 - 177
  • [26] A comparative analysis of ECG-gated steady state free precession magnetic resonance imaging versus transthoracic echocardiography for evaluation of aortic root dimensions
    Hoey, Edward T. D.
    Pakala, Vijaya
    Kassamali, Rahil H.
    Ganeshan, Arul
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2014, 4 (05) : 300 - 306
  • [27] Comparison of 3D-diffusion-prepared segmented steady-state free precession and 2D fast spin echo imaging of femoral artery atherosclerosis
    Katsumi Hayashi
    Venkatesh Mani
    Ajay Nemade
    Stephane Silvera
    Zahi A. Fayad
    The International Journal of Cardiovascular Imaging, 2010, 26 : 309 - 321
  • [28] Comparison of 3D-diffusion-prepared segmented steady-state free precession and 2D fast spin echo imaging of femoral artery atherosclerosis
    Hayashi, Katsumi
    Mani, Venkatesh
    Nemade, Ajay
    Silvera, Stephane
    Fayad, Zahi A.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2010, 26 (03) : 309 - 321
  • [29] Atherosclerotic plaque components in human aortas contrasted by ex vivo imaging using fast spin-echo magnetic resonance imaging and spiral computed tomography
    Halliburton, SS
    Paschal, CB
    INVESTIGATIVE RADIOLOGY, 1996, 31 (11) : 724 - 728
  • [30] Comparison of gradient-echo and steady-state free precession for coronary artery magnetic resonance angiography using a gadolinium-based intravascular contrast agent
    Deshpande, VS
    Cavagna, F
    Maggioni, F
    Schirf, BE
    Omary, RA
    Li, DB
    INVESTIGATIVE RADIOLOGY, 2006, 41 (03) : 292 - 298