Process control;
integrating plant;
fractional-order control;
internal model control;
Smith predictor;
integrating cascade process;
robustness;
load disturbance;
LOAD FREQUENCY CONTROL;
UNSTABLE PROCESSES;
TID CONTROLLER;
OUTER-LOOP;
DESIGN;
STRATEGY;
SYSTEMS;
D O I:
10.1177/09596518231168510
中图分类号:
TP [自动化技术、计算机技术];
学科分类号:
0812 ;
摘要:
This article proposes an enhanced control of integrating cascade processes. The importance of the scheme shows by controlling a double integrating process with time delay under significant parametric uncertainties and load disturbances. A novel design is proposed based on the Smith predictor principle and uses a fractional-order internal model controller in the outer loop. The required fractional-order tuning parameter follows the desired gain and phase margins. At the same time, another tuning parameter, such as the fractional filter's time constant, is calculated from the desired performance constraint. Numerical analysis and comparison are performed to showcase the feature of the hybrid structure. The simulation results show that the fractional-order internal model controller-based scheme provides enhanced tracking and faster regulation capabilities and works well under nominal and parameter uncertainty conditions.
引用
收藏
页码:1523 / 1541
页数:19
相关论文
共 38 条
[31]
Rayalla R., 2019, Eur J Electr Eng, V21, P139, DOI [10.18280/ejee.210203, DOI 10.18280/EJEE.210203]