Techno-economic evaluation of an off-grid hybrid PV-wind-diesel-battery system with various scenarios of system?s renewable energy fraction

被引:24
作者
Almashakbeh, Atef S. [1 ]
Arfoa, Aouda A. [1 ]
Hrayshat, Eyad S. [2 ]
机构
[1] Tafila Tech Univ, Coll Engn, Dept Mechatron & Power Engn, Tafila 66110, Jordan
[2] Tafila Tech Univ, Coll Engn, Dept Comp Engn & Commun & Elect Engn, Tafila, Jordan
关键词
Hybrid PV-wind-diesel-battery system; techno-economic analysis; sensitivity analysis; storage capacity; renewable energy fraction; HOMER; ELECTRICITY-GENERATION; PERFORMANCE ANALYSIS; SOLAR PHOTOVOLTAICS; POWER-SYSTEM; OPTIMIZATION; FEASIBILITY; ELECTRIFICATION; ISLAND; DESIGN; PLANT;
D O I
10.1080/15567036.2019.1673515
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
An off-grid hybrid PV-wind-diesel-battery system with the best hybrid combination of system?s components is designed to fulfill the electricity demand an off-grid village. For this purpose, five scenarios of system?s renewable energy fractions (namely 0% renewable energy, 25% renewable energy, 50% renewable energy, 75% renewable energy and 100% renewable energy) were modeled, simulated, optimized and analyzed. The results obtained using the Hybrid Optimization of Multiple Energy Resources (HOMER) software of the National Renewable Energy Laboratory (NREL)/USA showed that the hybrid system with 50% renewable energy fraction is the optimal one in terms of both its technical performance and the cost of generated electricity which was found to be $0.202/kWh. It was also proved that deploying this system for electricity generation reduces the emissions by 49% compared to the conventional system comprising only diesel generator sets. Moreover, a sensitivity analysis was conducted to reveal the impact of diesel prices, solar radiation and wind speed on the cost of generated ? by this optimal system ? electricity. The obtained results indicated that diesel price is the most influential factor in the cost of generated electricity. It changes from $0.168/kWh to $0.0.237/kWh for a variation in diesel prices from ?30% to +30% of its current prices. The effect of battery bank?s storage capacity on the performance and cost of electricity, generated by the optimal system was investigated as well. The results showed that varying the storage capacity from ?30% to +30% (from the base case value of 2971 kWh) increases the hybrid system?s capital cost, but reduces each of the excess electricity, diesel generators operation hours, the annual diesel consumption and consequently the CO2 emissions. However, increasing the storage capacity from ?30% till 0% (the base case), reduces the cost of electricity, while increasing the storage capacity from the base case of 0% to +30% does not affect the cost of generated electricity.
引用
收藏
页码:6162 / 6185
页数:24
相关论文
共 50 条
  • [41] Analysis of Hybrid Solar/Wind/Diesel Renewable Energy System for off-grid Rural Electrification
    Barzola, Julio
    Espinoza, Mayken
    Cabrera, Fausto
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2016, 6 (03): : 1146 - 1152
  • [42] Techno-economic and reliability assessment of an off-grid solar-powered energy system
    Saini, Krishna Kumar
    Sharma, Pavitra
    Mathur, Hitesh Datt
    Gautam, Aditya R.
    Bansal, Ramesh C.
    APPLIED ENERGY, 2024, 371
  • [43] Techno-Economic Evaluation of a Hybrid PV-Wind Power Generation System
    Dursun, Bahtiyar
    Gokcol, Cihan
    Umut, Ilhan
    Ucar, Erdem
    Kocabey, Sureyya
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2013, 10 (02) : 117 - 136
  • [44] Techno-economic and environmental analysis of an off-grid hybrid system using solar panels, wind turbine, diesel generator, and batteries for a rural health clinic considering
    Hai, Tao
    Shami, Hayder Oleiwi
    Ahmed, Mohsen
    Agarwal, Diwakar
    Rajab, Husam
    Mohammed, Adil Ismaeel
    Hussein, Abbas Hameed Abdul
    Hasan, Dheyaa Flayih
    Mushtaq, Hiba
    Singh, Narinderjit Singh Sawaran
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2024, 19 : 2195 - 2209
  • [45] Techno-economic analysis of a PV/WT/biomass off-grid hybrid power system for rural electrification in northern Morocco using HOMER
    El-Maaroufi, Abdellah
    Daoudi, Mohammed
    Laamara, Rachid Ahl
    RENEWABLE ENERGY, 2024, 231
  • [46] Techno-economic analysis of off-grid renewable energy power station: A case study
    Liu Liqun
    Liu Chunxia
    PRZEGLAD ELEKTROTECHNICZNY, 2012, 88 (7A): : 94 - 98
  • [47] Techno-Economic Analysis of Hybrid PV/Wind System Connected to Utility Grid
    Alharthi, Yahya Z.
    Siddiki, Mahbube K.
    Chaudhry, Ghulam M.
    2019 IEEE TEXAS POWER AND ENERGY CONFERENCE (TPEC), 2019,
  • [48] Papers Improved techno-economic optimization of an off-grid hybrid solar/wind/gravity energy storage system based on performance indicators
    Emrani, Anisa
    Berrada, Asmae
    Arechkik, Ameur
    Bakhouya, Mohamed
    JOURNAL OF ENERGY STORAGE, 2022, 49
  • [49] Autonomous smart switching control for off-grid hybrid PV/battery/diesel power system
    Soudan, Bassel
    Darya, Abdollah
    ENERGY, 2020, 211
  • [50] Control and Techno-Economic Analysis of PV-Diesel-Battery based Hybrid Microgrid System
    Barua, Ashutosh
    Jain, Arvind Kumar
    Gupta, Manish
    Mishra, Pankaj Kumar
    2017 CONFERENCE ON INFORMATION AND COMMUNICATION TECHNOLOGY (CICT), 2017,