Techno-economic evaluation of an off-grid hybrid PV-wind-diesel-battery system with various scenarios of system?s renewable energy fraction

被引:27
作者
Almashakbeh, Atef S. [1 ]
Arfoa, Aouda A. [1 ]
Hrayshat, Eyad S. [2 ]
机构
[1] Tafila Tech Univ, Coll Engn, Dept Mechatron & Power Engn, Tafila 66110, Jordan
[2] Tafila Tech Univ, Coll Engn, Dept Comp Engn & Commun & Elect Engn, Tafila, Jordan
关键词
Hybrid PV-wind-diesel-battery system; techno-economic analysis; sensitivity analysis; storage capacity; renewable energy fraction; HOMER; ELECTRICITY-GENERATION; PERFORMANCE ANALYSIS; SOLAR PHOTOVOLTAICS; POWER-SYSTEM; OPTIMIZATION; FEASIBILITY; ELECTRIFICATION; ISLAND; DESIGN; PLANT;
D O I
10.1080/15567036.2019.1673515
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
An off-grid hybrid PV-wind-diesel-battery system with the best hybrid combination of system?s components is designed to fulfill the electricity demand an off-grid village. For this purpose, five scenarios of system?s renewable energy fractions (namely 0% renewable energy, 25% renewable energy, 50% renewable energy, 75% renewable energy and 100% renewable energy) were modeled, simulated, optimized and analyzed. The results obtained using the Hybrid Optimization of Multiple Energy Resources (HOMER) software of the National Renewable Energy Laboratory (NREL)/USA showed that the hybrid system with 50% renewable energy fraction is the optimal one in terms of both its technical performance and the cost of generated electricity which was found to be $0.202/kWh. It was also proved that deploying this system for electricity generation reduces the emissions by 49% compared to the conventional system comprising only diesel generator sets. Moreover, a sensitivity analysis was conducted to reveal the impact of diesel prices, solar radiation and wind speed on the cost of generated ? by this optimal system ? electricity. The obtained results indicated that diesel price is the most influential factor in the cost of generated electricity. It changes from $0.168/kWh to $0.0.237/kWh for a variation in diesel prices from ?30% to +30% of its current prices. The effect of battery bank?s storage capacity on the performance and cost of electricity, generated by the optimal system was investigated as well. The results showed that varying the storage capacity from ?30% to +30% (from the base case value of 2971 kWh) increases the hybrid system?s capital cost, but reduces each of the excess electricity, diesel generators operation hours, the annual diesel consumption and consequently the CO2 emissions. However, increasing the storage capacity from ?30% till 0% (the base case), reduces the cost of electricity, while increasing the storage capacity from the base case of 0% to +30% does not affect the cost of generated electricity.
引用
收藏
页码:6162 / 6185
页数:24
相关论文
共 66 条
[61]  
The World Bank, 2017, DAT CAT
[62]   Modeling and optimization of batteryless hybrid PV (photovoltaic)/Diesel systems for off-grid applications [J].
Tsuanyo, David ;
Azoumah, Yao ;
Aussel, Didier ;
Neveu, Pierre .
ENERGY, 2015, 86 :152-163
[63]   Environmental impacts of small-scale hybrid energy systems: Coupling solar photovoltaics and lithium-ion batteries [J].
Uctug, Fehmi Gorkem ;
Azapagic, Adisa .
SCIENCE OF THE TOTAL ENVIRONMENT, 2018, 643 :1579-1589
[64]  
Wind Energy Solutions Co, 2018, WES250 BRING REN EN
[65]   Experimental study of electricity generation by Solar PV/diesel hybrid systems without battery storage for off-grid areas [J].
Yamegueu, D. ;
Azoumah, Y. ;
Py, X. ;
Zongo, N. .
RENEWABLE ENERGY, 2011, 36 (06) :1780-1787
[66]   Optimal design of hybrid PV-Diesel-Battery systems for isolated lands: A case study for Kilis, Turkey [J].
Yilmaz, Saban ;
Dincer, Furkan .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 77 :344-352