Convolution Based Time Domain Fault Location Method for Lines in MMC-HVDC Grids With Distributed and Frequency Dependent Line Model

被引:12
作者
Nie, Yuan [1 ,2 ,3 ,4 ]
Liu, Yu [5 ,6 ]
Pan, Ruiyu [1 ]
Lu, Dayou [1 ]
Fan, Rui [7 ]
机构
[1] ShanghaiTech Univ, Sch Informat Sci & Technol, Shanghai 201210, Peoples R China
[2] Chinese Acad Sci, Shanghai Adv Res Inst, Shanghai 201210, Peoples R China
[3] Chinese Acad Sci, Shanghai Inst Microsyst & Informat Technol, Shanghai 200050, Peoples R China
[4] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[5] ShanghaiTech Univ, Sch Informat Sci & Technol SIST, Shanghai 201210, Peoples R China
[6] Minist Educ, Key Lab Control Power Transmiss & Convers, Shanghai 200240, Peoples R China
[7] Univ Denver, Sch Engn & Comp Sci, Denver, CO 80208 USA
基金
中国国家自然科学基金;
关键词
Fault location; Mathematical models; Time-domain analysis; HVDC transmission; Frequency dependence; Multilevel converters; MMC-HVDC grids; frequency dependent line model; DYNAMIC STATE ESTIMATION; TRANSMISSION-LINES; TRAVELING-WAVE; NATURAL FREQUENCY; PROTECTION; PARAMETERS; ALGORITHM;
D O I
10.1109/TPWRD.2023.3294951
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, a convolution based time domain model based fault location method for lines is proposed in modular multilevel converter based high voltage direct current (MMC-HVDC) grids. The proposed method accurately considers the effect of distributed and frequency dependent line parameters. Two terminal measurements with 5 ms data window are utilized to calculate the accurate voltage distribution on the whole line to locate faults with relatively low sampling rate (10 kHz). First, since the existing convolution based frequency dependent line model (FDLM) is not suitable for the fault location problem, an improved convolution based FDLM is proposed. Second, to calculate the accurate voltage distributions along the line, improved curve fitting methods for the coefficients of the FDLM are proposed. Finally, to make the algorithm more practical, the convolution based time domain fault location algorithm is specially designed to greatly decrease the calculation burden. Simulation results prove the necessity of the improved curve fitting method, and demonstrate that the proposed method can accurately consider the frequency dependency of line. The proposed method shows much improved fault location results than the Bergeron model based methods in MMC-HVDC grids.
引用
收藏
页码:3860 / 3874
页数:15
相关论文
共 45 条
[41]   A Model-Based DC Fault Location Scheme for Multi-Terminal MMC-HVDC Systems Using a Simplified Transmission Line Representation [J].
Xu, Jianzhong ;
Lu, Yu ;
Zhao, Chengyong ;
Liang, Jun .
IEEE TRANSACTIONS ON POWER DELIVERY, 2020, 35 (01) :386-395
[42]  
Yi L., 2022, P IEEE POW EN SOC GE, P1
[43]   Non-Unit Ultra-High-Speed DC Line Protection Method for HVDC Grids Using First Peak Time of Voltage [J].
Zhang, Chenhao ;
Song, Guobing ;
Dong, Xinzhou .
IEEE TRANSACTIONS ON POWER DELIVERY, 2021, 36 (03) :1683-1693
[44]   A Novel Traveling Wave Protection Method for DC Transmission Lines Using Current Fitting [J].
Zhang, Chenhao ;
Song, Guobing ;
Dong, Xinzhou .
IEEE TRANSACTIONS ON POWER DELIVERY, 2020, 35 (06) :2980-2991
[45]   Single-Ended Traveling Wave Fault Location Method in DC Transmission Line Based on Wave Front Information [J].
Zhang, Chenhao ;
Song, Guobing ;
Wang, Ting ;
Yang, Liming .
IEEE TRANSACTIONS ON POWER DELIVERY, 2019, 34 (05) :2028-2038