Impact of TAVR on coronary artery hemodynamics using clinical measurements and image-based patient-specific in silico modeling

被引:5
|
作者
Garber, Louis [1 ]
Khodaei, Seyedvahid [2 ]
Maftoon, Nima [3 ,4 ]
Keshavarz-Motamed, Zahra [1 ,2 ,5 ]
机构
[1] McMaster Univ, Sch Biomed Engn, Hamilton, ON, Canada
[2] McMaster Univ, Dept Mech Engn, Hamilton, ON L8S 4L7, Canada
[3] Univ Waterloo, Dept Syst Design Engn, Waterloo, ON, Canada
[4] Univ Waterloo, Ctr Bioengn & Biotechnol, Waterloo, ON, Canada
[5] McMaster Univ, Sch Computat Sci & Engn, Hamilton, ON, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
TRANSCATHETER AORTIC-VALVE; FRACTIONAL FLOW RESERVE; COMPUTATIONAL FLUID-DYNAMICS; BLOOD-FLOW; COMPUTED-TOMOGRAPHY; STENOSIS; VELOCITY; QUANTIFICATION; IMPLANTATION; COARCTATION;
D O I
10.1038/s41598-023-31987-w
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
In recent years, transcatheter aortic valve replacement (TAVR) has become the leading method for treating aortic stenosis. While the procedure has improved dramatically in the past decade, there are still uncertainties about the impact of TAVR on coronary blood flow. Recent research has indicated that negative coronary events after TAVR may be partially driven by impaired coronary blood flow dynamics. Furthermore, the current technologies to rapidly obtain non-invasive coronary blood flow data are relatively limited. Herein, we present a lumped parameter computational model to simulate coronary blood flow in the main arteries as well as a series of cardiovascular hemodynamic metrics. The model was designed to only use a few inputs parameters from echocardiography, computed tomography and a sphygmomanometer. The novel computational model was then validated and applied to 19 patients undergoing TAVR to examine the impact of the procedure on coronary blood flow in the left anterior descending (LAD) artery, left circumflex (LCX) artery and right coronary artery (RCA) and various global hemodynamics metrics. Based on our findings, the changes in coronary blood flow after TAVR varied and were subject specific (37% had increased flow in all three coronary arteries, 32% had decreased flow in all coronary arteries, and 31% had both increased and decreased flow in different coronary arteries). Additionally, valvular pressure gradient, left ventricle (LV) workload and maximum LV pressure decreased by 61.5%, 4.5% and 13.0% respectively, while mean arterial pressure and cardiac output increased by 6.9% and 9.9% after TAVR. By applying this proof-of-concept computational model, a series of hemodynamic metrics were generated non-invasively which can help to better understand the individual relationships between TAVR and mean and peak coronary flow rates. In the future, tools such as these may play a vital role by providing clinicians with rapid insight into various cardiac and coronary metrics, rendering the planning for TAVR and other cardiovascular procedures more personalized.
引用
收藏
页数:19
相关论文
共 50 条
  • [21] Hemodynamics of Proximal Coronary Lesions in Patient Undergoing Aortic Valve Replacement: Patient-Specific In Silico Study
    Bellouche, Yahia
    Abdelli, Sirine
    Mansourati, Jacques
    Le Ven, Florent
    Didier, Romain
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 82 (17) : B29 - B29
  • [22] Image-based finite element Modeling of Hemodynamics in stenosed carotid artery
    Cebral, JR
    Löhner, R
    Soto, O
    Choyke, PL
    Yim, PJ
    MEDICAL IMAGING 2002: PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES, 2002, 4683 : 297 - 304
  • [23] Image based CFD modeling of coronary artery wall shear stress and importance of patient-specific velocity boundary conditions
    Johnson, Kevin R.
    Oshinski, John N.
    PROCEEDING OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2007, 2007, : 555 - 556
  • [24] Image-based biomarkers for engineering neuroblastoma patient-specific computational models
    Hervas-Raluy, Silvia
    Sainz-DeMena, Diego
    Gomez-Benito, Maria Jose
    Garcia-Aznar, Jose Manuel
    ENGINEERING WITH COMPUTERS, 2024, 40 (05) : 3215 - 3231
  • [25] Towards a Digital Twin of Coronary Stenting: A Suitable and Validated Image-Based Approach for Mimicking Patient-Specific Coronary Arteries
    Poletti, Gianluca
    Antonini, Luca
    Mandelli, Lorenzo
    Tsompou, Panagiota
    Karanasiou, Georgia S.
    Papafaklis, Michail, I
    Michalis, Lampros K.
    Fotiadis, Dimitrios, I
    Petrini, Lorenza
    Pennati, Giancarlo
    ELECTRONICS, 2022, 11 (03)
  • [26] Image-Based Estimation of Ventricular Fiber Orientations for Patient-Specific Simulations
    Vadakkumpadan, Fijoy
    Arevalo, Hermenegild
    Ceritoglu, Can
    Miller, Michael
    Trayanova, Natalia
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 1672 - 1675
  • [27] A fluid-structure interaction analysis on hemodynamics in carotid artery based on patient-specific clinical data
    Lee, Sang Hyuk
    Kang, Seongwon
    Hur, Nahmkeon
    Jeong, Seul-Ki
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2012, 26 (12) : 3821 - 3831
  • [28] A fluid-structure interaction analysis on hemodynamics in carotid artery based on patient-specific clinical data
    Sang Hyuk Lee
    Seongwon Kang
    Nahmkeon Hur
    Seul-Ki Jeong
    Journal of Mechanical Science and Technology, 2012, 26 : 3821 - 3831
  • [29] Long-term prognostic impact of paravalvular leakage on coronary artery disease requires patient-specific quantification of hemodynamics
    Khodaei, Seyedvahid
    Garber, Louis
    Bauer, Julia
    Emadi, Ali
    Keshavarz-Motamed, Zahra
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [30] Long-term prognostic impact of paravalvular leakage on coronary artery disease requires patient-specific quantification of hemodynamics
    Seyedvahid Khodaei
    Louis Garber
    Julia Bauer
    Ali Emadi
    Zahra Keshavarz-Motamed
    Scientific Reports, 12