Diagnostic performance of Kaiser score in patients with newly diagnosed breast cancer: Factors associated with false-negative results

被引:5
|
作者
Aslan, Aydan Avdan [1 ,2 ]
Gultekin, Serap [1 ]
机构
[1] Gazi Univ, Fac Med, Dept Radiol, Ankara, Turkiye
[2] Gazi Univ, Fac Med, Dept Radiol, Emniyet, Mevlana Blv 29, TR-06560 Ankara, Turkiye
关键词
Kaiser score; Magnetic resonance imaging; Breast cancer; Scoring system; SKIN-SPARING MASTECTOMY; LOCAL RECURRENCE; MRI; SYSTEM; TREE;
D O I
10.1016/j.ejrad.2023.110864
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the factors associated with false-negative results in the diagnosis of breast cancer via breast magnetic resonance imaging (MRI) using the Kaiser score (KS).Methods: This institutional review board (IRB)-approved, single-center, retrospective study enrolled 219 consecutive histopathologically proven breast cancer lesions in 205 women who underwent preoperative breast MRI. Two breast radiologists evaluated each lesion according to the KS. The clinicopathological characteristics and imaging findings were also analyzed. Interobserver variability was assessed using the intraclass correlation coefficient (ICC). Multivariate regression analysis was used to investigate factors associated with false-negative KS results for breast cancer diagnosis.Results: Of 219 breast cancers, KS yielded 200 (91.3%) true-positive and 19 (8.7%) false-negative results. The interobserver ICC for the KS between the two readers was good, with a value of 0.804 (95% CI 0.751-0.846). Multivariate regression analysis revealed that small lesion size (<= 1 cm) (adjusted OR 6.86, 95% CI 2.14-21.94, p = 0.001) and personal breast cancer history (adjusted OR 7.59, 95% CI, 1.55-37.23, p = 0.012) were significantly associated with false-negative KS results.Conclusion: Small lesion size (<= 1 cm) and presence of personal breast cancer history are factors significantly associated with false-negative KS results. Our results suggest that radiologists should consider these factors in clinical practice as potential pitfalls of KS, which may be compensated for by a multimodal approach combined with clinical evaluation.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Kaiser score diagnosis of breast MRI lesions: Factors associated with false-negative and false-positive results
    Zhang, Bing
    Guo, Zhuanzhuan
    Lei, Zhe
    Liang, Wenbin
    Chen, Xin
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 178
  • [2] False-negative results of breast MR computer-aided evaluation in patients with breast cancer: correlation with clinicopathologic and radiologic factors
    Shin, YunKyung
    Sohn, Yu-Mee
    Seo, Mirinae
    Han, Kyunghwa
    CLINICAL IMAGING, 2016, 40 (06) : 1086 - 1091
  • [3] Diagnostic performance of Kaiser score in the evaluation of breast cancer using MRI: A systematic review and meta-analysis
    Mohammadzadeh, Saeed
    Mohebbi, Alisa
    Moradi, Zahra
    Abdi, Ali
    Mohammadi, Afshin
    Hakim, Peyman Kamali
    Ahmadinejad, Nasrin
    Zeinalkhani, Fahimeh
    EUROPEAN JOURNAL OF RADIOLOGY, 2025, 186
  • [4] Factors affecting false-negative breast sentinel node biopsy in chinese patients
    Chok, Kenneth S. H.
    Suen, Dacita T. K.
    Lim, Fiona M. Y.
    Li, George K. H.
    Kwong, Ava
    ANZ JOURNAL OF SURGERY, 2007, 77 (10) : 866 - 869
  • [5] False-Negative and False-Positive Results in FDG-PET and PET/CT in Breast Cancer
    Kumar, Rakesh
    Rani, Neerja
    Patel, Chetan
    Basu, Sandip
    Alavi, Abass
    PET CLINICS, 2009, 4 (03) : 289 - 298
  • [6] False-negative results on computer-aided detection software in preoperative automated breast ultrasonography of breast cancer patients
    Kim, Youngjune
    Rim, Jiwon
    Kim, Sun Mi
    Yun, Bo La
    Park, So Yeon
    Ahn, Hye Shin
    Kim, Bohyoung
    Jang, Mijung
    ULTRASONOGRAPHY, 2021, 40 (01) : 83 - 92
  • [7] A mini-review on factors and countermeasures associated with false-negative sentinel lymph node biopsies in breast cancer
    Han, Chao
    Yang, Li
    Zuo, Wenshu
    CHINESE JOURNAL OF CANCER RESEARCH, 2016, 28 (03) : 370 - 376
  • [8] A mini-review on factors and countermeasures associated with false-negative sentinel lymph node biopsies in breast cancer
    Chao Han
    Li Yang
    Wenshu Zuo
    Chinese Journal of Cancer Research, 2016, 28 (03) : 370 - 376
  • [9] Performance of breast magnetic resonance imaging in axillary nodal staging in newly diagnosed breast cancer patients
    Chayakulkheeree, Jatuporn
    Pungrassami, Dirapit
    Prueksadee, Jenjeera
    POLISH JOURNAL OF RADIOLOGY, 2019, 84 : E413 - E418
  • [10] A nomogram based on multiparametric magnetic resonance imaging improves the diagnostic performance of breast lesions diagnosed as BI-RADS category 4: A comparative study with the Kaiser score
    Yang, Xiao
    Lu, Zhou
    Tan, Xiaoying
    Shao, Lin
    Shi, Jie
    Dou, Weiqiang
    Sun, Zongqiong
    EUROPEAN JOURNAL OF RADIOLOGY, 2025, 183