High intermediate precision Sm isotope measurements in geological samples by MC-ICP-MS

被引:11
|
作者
Bai, Jiang-Hao [1 ,2 ,4 ]
Lin, Mang [1 ]
Zhong, Song-Xiong [3 ]
Deng, Yi-Nan [2 ]
Zhang, Le [1 ]
Luo, Kai [1 ,4 ]
Wu, Hao [1 ,4 ]
Ma, Jin-Long [1 ]
Wei, Gang-Jian [1 ]
机构
[1] Chinese Acad Sci, Guangzhou Inst Geochem, CAS Ctr Excellence Deep Earth Sci, State Key Lab Isotope Geochem, Guangzhou 510640, Peoples R China
[2] Minist Nat & Resources, Key Lab Marine Mineral Resources, Guangzhou 511458, Peoples R China
[3] Guangdong Acad Sci, Inst Ecoenvironm & Soil Sci, Natl Reg Joint Engn Res Ctr Soil Pollut Control &, Key Lab Integrated Agroenvironm Pollut Control & M, Guangzhou 510650, Guangdong, Peoples R China
[4] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
RARE-EARTH-ELEMENTS; TODGA RESIN COLUMN; HALF-LIFE; SEPARATION; NEODYMIUM; ND; FRACTIONATION; EXTRACTION; RATIO; EVOLUTION;
D O I
10.1039/d2ja00412g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The measurement of Sm isotopes in geological materials is challenging, thus limiting their extensive applications in geoscience and environmental science. Herein, we developed a technique for the high intermediate precision analysis of Sm isotopes via multi-collector-inductively coupled plasma-mass spectrometry (MC-ICP-MS). Interference impurities, particularly Nd, Eu, and Gd, were completely removed from Sm using a new two-column [AG50W-X12 (200-400 mesh) and TODGA (50-100 mu m)] procedure, which quantitatively (99.4 +/- 0.3%) extracted Sm. The complete purification of Sm allowed the development of a high intermediate precision calibration method combined with standard-sample bracketing and Eu internal normalization to correct the instrumental mass bias. A long-term intermediate precision better than 0.04 parts per thousand (2SD) for delta Sm-152/149 was obtained. This intermediate precision is significantly better than those of the existing MC-ICP-MS methods (0.15 parts per thousand-0.30 parts per thousand) and double spike-thermal ionization mass spectrometry methods (0.15 parts per thousand-0.20 parts per thousand), as confirmed by multiple purifications and measurements of 11 geological reference materials (GRMs) with different rock types (e.g., basalt, andesite, granodiorite, granite, nepheline, syenite, manganese nodule, and marine sediment). In addition, we observed a detectable variation in delta Sm-152/149 (0.22 parts per thousand) among these 11 GRMs, which could not be identified at the previous intermediate precision. This finding highlights that the high intermediate precision delta Sm-152/149 measurements in natural samples established herein have the potential to provide new constraints on diverse natural processes, ranging from planetary formation to chemical weathering and ocean circulation and create new opportunities for stable Sm isotope studies.
引用
收藏
页码:629 / 637
页数:10
相关论文
共 50 条
  • [41] High-precision lithium isotopic analysis using the Nu Sapphire MC-ICP-MS
    Liu, Shanke
    Li, Wenjun
    Su, Benxun
    Gao, Bingyu
    Wang, Jing
    Wang, Changle
    Luo, Yang
    Yan, Lizhi
    Zhao, Ye
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2023, 38 (03) : 656 - 666
  • [42] A Review of Mg Isotope Analytical Methods by MC-ICP-MS
    An, Yajun
    Huang, Fang
    JOURNAL OF EARTH SCIENCE, 2014, 25 (05) : 822 - 840
  • [43] Effective Correction of Mass Bias for Rhenium Measurements by MC-ICP-MS
    Poirier, Andre
    Doucelance, Regis
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2009, 33 (02) : 195 - 204
  • [44] Solution and laser ablation MC-ICP-MS lead isotope analysis of gold
    Standish, Christopher
    Dhuime, Bruno
    Chapman, Robert
    Coath, Christopher
    Hawkesworth, Chris
    Pike, Alistair
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2013, 28 (02) : 217 - 225
  • [45] Nickel Isotope Variations in Terrestrial Silicate Rocks and Geological Reference Materials Measured by MC-ICP-MS
    Gueguen, Bleuenn
    Rouxel, Olivier
    Ponzevera, Emmanuel
    Bekker, Andrey
    Fouquet, Yves
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2013, 37 (03) : 297 - 317
  • [46] High-precision potassium isotope analysis using the Nu Sapphire collision cell (CC)-MC-ICP-MS
    Li, Wenjun
    Cui, Mengmeng
    Pan, Qiqi
    Wang, Jing
    Gao, Bingyu
    Liu, Shanke
    Yuan, Meng
    Su, Benxun
    Zhao, Ye
    Teng, Fang-Zhen
    Han, Guilin
    SCIENCE CHINA-EARTH SCIENCES, 2022, 65 (08) : 1510 - 1521
  • [47] A validated analytical procedure for boron isotope analysis in plants by MC-ICP-MS
    Xiao, Jun
    Vogl, Jochen
    Rosner, Martin
    Deng, Li
    Jin, Zhangdong
    TALANTA, 2019, 196 : 389 - 394
  • [48] Barium isotopic analysis of geological reference materials by MC-ICP-MS
    Ma, Shunrong
    Han, Guilin
    Zhang, Qian
    Liu, Jinke
    Ding, Ziyang
    Zhao, Ye
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2025, 228
  • [49] Measurement on high-precision boron isotope of silicate materials by a single column purification method and MC-ICP-MS
    Wei Gangjian
    Wei Jingxian
    Liu Ying
    Ke Ting
    Ren Zhongyuan
    Ma Jinlong
    Xu Yigang
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2013, 28 (04) : 606 - 612
  • [50] High-sensitivity tracing of stable isotope labeled Ag nanoparticles in environmental samples using MC-ICP-MS
    Junk, Tabea
    Rehkamper, Mark
    Laycock, Adam
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (06) : 1173 - 1183