High intermediate precision Sm isotope measurements in geological samples by MC-ICP-MS

被引:11
|
作者
Bai, Jiang-Hao [1 ,2 ,4 ]
Lin, Mang [1 ]
Zhong, Song-Xiong [3 ]
Deng, Yi-Nan [2 ]
Zhang, Le [1 ]
Luo, Kai [1 ,4 ]
Wu, Hao [1 ,4 ]
Ma, Jin-Long [1 ]
Wei, Gang-Jian [1 ]
机构
[1] Chinese Acad Sci, Guangzhou Inst Geochem, CAS Ctr Excellence Deep Earth Sci, State Key Lab Isotope Geochem, Guangzhou 510640, Peoples R China
[2] Minist Nat & Resources, Key Lab Marine Mineral Resources, Guangzhou 511458, Peoples R China
[3] Guangdong Acad Sci, Inst Ecoenvironm & Soil Sci, Natl Reg Joint Engn Res Ctr Soil Pollut Control &, Key Lab Integrated Agroenvironm Pollut Control & M, Guangzhou 510650, Guangdong, Peoples R China
[4] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
RARE-EARTH-ELEMENTS; TODGA RESIN COLUMN; HALF-LIFE; SEPARATION; NEODYMIUM; ND; FRACTIONATION; EXTRACTION; RATIO; EVOLUTION;
D O I
10.1039/d2ja00412g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The measurement of Sm isotopes in geological materials is challenging, thus limiting their extensive applications in geoscience and environmental science. Herein, we developed a technique for the high intermediate precision analysis of Sm isotopes via multi-collector-inductively coupled plasma-mass spectrometry (MC-ICP-MS). Interference impurities, particularly Nd, Eu, and Gd, were completely removed from Sm using a new two-column [AG50W-X12 (200-400 mesh) and TODGA (50-100 mu m)] procedure, which quantitatively (99.4 +/- 0.3%) extracted Sm. The complete purification of Sm allowed the development of a high intermediate precision calibration method combined with standard-sample bracketing and Eu internal normalization to correct the instrumental mass bias. A long-term intermediate precision better than 0.04 parts per thousand (2SD) for delta Sm-152/149 was obtained. This intermediate precision is significantly better than those of the existing MC-ICP-MS methods (0.15 parts per thousand-0.30 parts per thousand) and double spike-thermal ionization mass spectrometry methods (0.15 parts per thousand-0.20 parts per thousand), as confirmed by multiple purifications and measurements of 11 geological reference materials (GRMs) with different rock types (e.g., basalt, andesite, granodiorite, granite, nepheline, syenite, manganese nodule, and marine sediment). In addition, we observed a detectable variation in delta Sm-152/149 (0.22 parts per thousand) among these 11 GRMs, which could not be identified at the previous intermediate precision. This finding highlights that the high intermediate precision delta Sm-152/149 measurements in natural samples established herein have the potential to provide new constraints on diverse natural processes, ranging from planetary formation to chemical weathering and ocean circulation and create new opportunities for stable Sm isotope studies.
引用
收藏
页码:629 / 637
页数:10
相关论文
共 50 条
  • [1] High precision Rb isotope measurements by MC-ICP-MS
    Hu, Xia
    Nan, Xiao-Yun
    Yu, Hui-Min
    Huang, Fang
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2021, 36 (12) : 2744 - 2755
  • [2] High-precision barium isotope measurements by MC-ICP-MS
    Nan, Xiaoyun
    Wu, Fei
    Zhang, Zhaofeng
    Hou, Zhenhui
    Huang, Fang
    Yu, Huimin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2015, 30 (11) : 2307 - 2315
  • [3] Ce and Nd stable isotope purification and determination of geological samples by MC-ICP-MS
    Bai, Jiang-Hao
    Ma, Jin-Long
    Wei, Gang-Jian
    Zhang, Le
    Zhong, Song-Xiong
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (08) : 1618 - 1628
  • [4] Stable cerium isotope analysis of geological materials by MC-ICP-MS
    Liu, Fang
    Ling, Mingxing
    Zhang, Zhaofeng
    Lu, Wenning
    Xu, Jianbing
    Li, Xin
    Yang, Di
    Wu, Jiaojiao
    Yang, Hong
    CHEMICAL GEOLOGY, 2023, 637
  • [5] High precision measurements of gallium isotopic compositions in geological materials by MC-ICP-MS
    Zhang, Ting
    Zhou, Lian
    Yang, Lu
    Wang, Qian
    Feng, Lan-ping
    Liu, Yong-Sheng
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (08) : 1673 - 1679
  • [6] High-Precision Iron Isotope Analysis of Geological Reference Materials by High-Resolution MC-ICP-MS
    He, Yongsheng
    Ke, Shan
    Teng, Fang-Zhen
    Wang, Tiantian
    Wu, Hongjie
    Lu, Yinhuai
    Li, Shuguang
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2015, 39 (03) : 341 - 356
  • [7] Precise and accurate determination of Sm, Nd concentrations and Nd isotopic compositions in geological samples by MC-ICP-MS
    Yang, Yue-Heng
    Chu, Zhu-Yin
    Wu, Fu-Yuan
    Xie, Lie-Wen
    Yang, Jin-Hui
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2011, 26 (06) : 1237 - 1244
  • [8] Rubidium Isotope Measurements of Low-Rb Geological Materials by MC-ICP-MS
    Zhang, Ya-Qi
    Wei, Wei
    Zhang, Zhuoying
    Hu, Xia
    Yu, Hui-Min
    Huang, Fang
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2024,
  • [9] Gd matrix effects on Eu isotope fractionation using MC-ICP-MS: Optimizing europium isotope ratio measurements in geological rock samples
    Lee, Seung-Gu
    Tanaka, Tsuyoshi
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2021, 469
  • [10] High-precision double-spike Sn isotope analysis of geological materials by MC-ICP-MS
    She, Jia-Xin
    Li, Weiqiang
    An, Shichao
    Cai, Yuanfeng
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2023, 38 (01) : 142 - 155