Seismic performance of short precast bridge columns with grouted splice sleeve (GSS) connectors for shear study: Quasi-static cyclic test and analytical estimation

被引:14
作者
Wang, Zhiqiang [1 ]
Zhang, Jiyan [1 ]
Lv, Hao [2 ]
Yan, Xingfei [2 ]
Li, Tiantian [3 ]
Qu, Hongya [1 ]
机构
[1] Tongji Univ, Dept Bridge Engn, 1239 Siping Rd, Shanghai 200092, Peoples R China
[2] Shanghai Urban Construct Design Res Inst Grp Co Lt, 3447 Dongfang Rd, Shanghai 200125, Peoples R China
[3] Shanghai Typhoon Inst China Meteorol Adm, 166 Puxi Rd, Shanghai 200030, Peoples R China
基金
中国国家自然科学基金;
关键词
Quasi -static cyclic test; Precast column; Grouted splice sleeve; Shear strength; Failure mechanism; Analytical solution; REINFORCED-CONCRETE BEAMS; TRUSS-MODEL; BOND STRENGTH; BEHAVIOR; JOINTS; BARS; FAILURE; MEMBERS; STEEL;
D O I
10.1016/j.soildyn.2022.107659
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
In this study, shear damage development of four precast bridge columns with different connection design details are first examined via quasi-static test. The short columns are of identical dimension and reinforcement arrangement for both pier and footing segments, and the span-to-depth ratio is 0.85 for shear study. The connection utilizes grouted splice sleeve (GSS) couplers for all four specimens. Different bonding materials are compared, effectiveness of shear keys is investigated, and variation of steel rebar grades is carried out. It is found that epoxy retain lower bond strength than high strength mortar, lower grade of longitudinal rebar significantly reduces shear strength of bridge column, and shear keys are of limited effectiveness on the overall shear damage development. An analytical method for shear strength calculation is then proposed and calibrated based on different test results, which incorporates possible influencing factors for shear strength estimation. Maximum difference between the test results and estimated strength values are less than 10%, and it indicates that the proposed method can be used as a reference for shear strength estimation of short precast bridge columns for seismic strength estimation.
引用
收藏
页数:13
相关论文
共 71 条
  • [1] ACI (American Concrete Institute), 2019, ACI31808
  • [2] Stresses, deformations and damages of various joints in precast concrete segmental box girder bridges subjected to direct shear loading
    Ahmed, Ghafur H.
    Aziz, Omar Q.
    [J]. ENGINEERING STRUCTURES, 2020, 206
  • [3] Shifted Plastic Hinging for Grouted Sleeve Column Connections
    Al-Jelawy, Haider M.
    Mackie, Kevin R.
    Haber, Zachary B.
    [J]. ACI STRUCTURAL JOURNAL, 2018, 115 (04) : 1101 - 1114
  • [4] [Anonymous], 2009, AASHTO GUID SPEC LRF, V1st
  • [5] [Anonymous], 2019, Caltrans Seismic Design Criteria Version 2.0
  • [6] [Anonymous], 2013, fib model code for concrete structures 2010
  • [7] Arai T, 2000, KATRI ANN REP, V48, P25
  • [8] Ascheim M, 1992, UCBEERC9204
  • [9] Belleri A, 2012, PCI J, P97