Self-cleaning sensors based on thermoresponsive polymeric film modified screen-printed platinum electrodes

被引:2
|
作者
Yang, Lei [1 ,2 ]
Lopes, Ilanna Campelo [2 ,3 ]
Vadgama, Pankaj [1 ,2 ]
机构
[1] Liaoning Petrochem Univ, Sch Petrochem Engn, Fushun 113001, Peoples R China
[2] Queen Mary Univ London, Sch Engn & Mat Sci, London E1 4NS, England
[3] Univ Fed Maranhao, Dept Tecnol Quim, Ctr Ciencias Exatas & Tecnol, BR-65080805 Sao Luis, MA, Brazil
基金
中国国家自然科学基金;
关键词
Poly(N-isopropylacrylamide) (NIPAAm); N-vinyl pyrrolidone (NVP); Electrochemical sensors; Self-cleaning films; Anti-biofouling ability; PROTEIN ADSORPTION; SWELLING BEHAVIOR; CELL-ADHESION; PVDF MEMBRANE; POLY(N-ISOPROPYLACRYLAMIDE); COPOLYMERS; SEPARATION; MECHANISM; GROWTH;
D O I
10.1016/j.cej.2023.145932
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Electrochemical sensors have progressively become important tools for monitoring the concentration of complex substances in biological media. However, surface fouling and biological contamination from bio-colloids have not been effectively resolved. In this study, a self-cleaning electrochemical sensor was constructed where a thermoresponsive outer polymer layer was equipped to repel the absorbent proteins. Enhanced hydrophilic P (NIPAAm-co-NVP) copolymers bearing N-isopropylacrylamide (NIPAAm) and N-vinyl pyrrolidone (NVP) were synthesized by free radical polymerization, and the resulting thermoresponsive polymeric films were drop coated on screen-printed platinum electrodes (SPPEs) followed by thermal annealing. Grafting density, surface wettability, surface microstructure, amperometric response, electrochemical active surface area (EAS) and other performances, were evaluated for the modified SPPEs. Self-cleaning behavior after albumin adsorption was assessed by cyclic voltammetry (CV) and scanning electron microscopy (SEM) using various set temperatures respectively. The results showed the lower critical solution temperature (LCST) varied from 25 degrees C to 40 degrees C for P (NIPAAm-co-NVP) copolymers with the NVP content ranging from 0 to 47.62%. It indicated that NVP enhanced film hydrophilicity and could raise the LCST to above physiological data. The thermosensitivity, stability and repeatability of the modified sensors was proved to be well, and the unchanged selectivity was consistent with bare platinum electrodes. The copolymer film modified SPPEs showed the decreased and temperature-dependent EAS compared with bare SPPEs. It was concluded that films without NVP or with low NVP content resisted protein adsorption over lower temperatures, whilst with higher NVP content outstanding self-cleaning ability was also seen at physiological temperature. This opens the way to realize smart thermally addressable sensors able to solve the existing problem of biological surface contamination in sensor systems, and provides a strong model basis and technical capability for achieving novel, low drift electrochemical sensors.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Development of a Rapid, Antimicrobial Susceptibility Test for E. coli Based on Low-Cost, Screen-Printed Electrodes
    Hannah, Stuart
    Dobrea, Alexandra
    Lasserre, Perrine
    Blair, Ewen O.
    Alcorn, David
    Hoskisson, Paul A.
    Corrigan, Damion K.
    BIOSENSORS-BASEL, 2020, 10 (11):
  • [32] Low-cost and disposable sensors for the simultaneous determination of coenzyme Q10 and α-lipoic acid using manganese (IV) oxide-modified screen-printed graphene electrodes
    Charoenkitamorn, Kanokwan
    Chaiyo, Sudkate
    Chailapakul, Orawon
    Siangproh, Weena
    ANALYTICA CHIMICA ACTA, 2018, 1004 : 22 - 31
  • [33] Design of screen-printed bulk modified electrodes using anthraquinone-cysteamine functionalized gold nanoparticles and their application to the detection of dissolved oxygen
    Tiwari, Ida
    Singh, Monali
    Gupta, Mandakini
    Metters, Jonathan P.
    Banks, Craig E.
    ANALYTICAL METHODS, 2015, 7 (05) : 2020 - 2027
  • [34] Amperometric Determination of Glucose in White Grape and in Tablets as Ingredient by Screen-Printed Electrode Modified with Glucose Oxidase and Composite of Platinum and Multiwalled Carbon Nanotubes
    Guzsvany, Valeria
    Anojcic, Jasmina
    Vajdle, Olga
    Radulovic, Emil
    Madarasz, Daniel
    Konya, Zoltan
    Kalcher, Kurt
    FOOD ANALYTICAL METHODS, 2019, 12 (02) : 570 - 580
  • [35] Electrochemically reduced graphene oxide-modified screen-printed carbon electrodes for a simple and highly sensitive electrochemical detection of synthetic colorants in beverages
    Jampasa, Sakda
    Siangproh, Weena
    Duangmal, Kiattisak
    Chailapakul, Orawon
    TALANTA, 2016, 160 : 113 - 124
  • [36] Enhancing the Oil-Fouling Resistance of Polymeric Membrane Ion-Selective Electrodes by Surface Modification of a Zwitterionic Polymer-Based Oleophobic Self-Cleaning Coating
    Qi, Longbin
    Jiang, Tianjia
    Liang, Rongning
    Qin, Wei
    ANALYTICAL CHEMISTRY, 2021, 93 (18) : 6932 - 6937
  • [37] Poly-methionine/graphitic carbon nitride modified screen-printed electrodes: A metal-free, bio-interface for tryptophan sensing
    Singh, Ankush Kumar
    Yadav, Rashmi
    Singh, Rosy Abhay
    MATERIALS CHEMISTRY AND PHYSICS, 2024, 328
  • [38] Simultaneous and selective determination of dopamine and tyrosine in the presence of uric acid with 2D-MoS2 nanosheets modified screen-printed carbon electrodes
    Zribi, Rayhane
    Maalej, Ramzi
    Gillibert, Raymond
    Donato, Maria G.
    Gucciardi, Pietro G.
    Leonardi, Salvatore G.
    Neri, Giovanni
    FLATCHEM, 2020, 24
  • [39] Electroanalysis of ethyl-centralite propellant stabiliser at magnetic nanoparticle modified glassy carbon and screen-printed electrodes with extension to forensic firearm residue analysis
    McKeever, Colm
    Dempsey, Eithne
    SENSORS AND ACTUATORS B-CHEMICAL, 2023, 396
  • [40] Amperometric phenol biosensor based on covalent immobilization of tyrosinase on Au nanoparticle modified screen printed carbon electrodes
    Karim, Md Nurul
    Lee, Hye Jin
    TALANTA, 2013, 116 : 991 - 996