Acquiring Hyperpolarized 129Xe Magnetic Resonance Images of Lung Ventilation

被引:0
作者
Garrison, William J. [1 ]
Mugler, John P., III [1 ,2 ]
Mata, Jaime F. [2 ]
Nunoo-Asare, Roselove N. [2 ]
Shim, Y. Michael [3 ]
Miller, G. Wilson [1 ,2 ,4 ]
机构
[1] Univ Virginia, Dept Biomed Engn, Charlottesville, VA 22903 USA
[2] Univ Virginia, Dept Radiol & Med Imaging, Charlottesville, VA 22903 USA
[3] Univ Virginia, Dept Med, Charlottesville, VA USA
[4] Univ Virginia, Dept Phys, Charlottesville, VA 22903 USA
来源
JOVE-JOURNAL OF VISUALIZED EXPERIMENTS | 2023年 / 201期
基金
美国国家卫生研究院;
关键词
XE-129; MRI; HEALTHY-VOLUNTEERS; PULMONARY-FIBROSIS; GAS; ASTHMA; HE-3; TOLERABILITY; SPECTROSCOPY; (129)XENON; QUANTIFY;
D O I
10.3791/65982
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Hyperpolarized 129Xe MRI comprises a unique array of structural and functional lung imaging techniques. Technique standardization across sites is increasingly important given the recent FDA approval of 129Xe as an MR contrast agent and as interest in 129Xe MRI increases among research and clinical institutions. Members of the 129Xe MRI Clinical Trials Consortium (Xe MRI CTC) have agreed upon best practices for each of the key aspects of the 129Xe MRI workflow, and these recommendations are summarized in a recent publication. This work provides practical information to develop an end-to-end workflow for collecting 129Xe MR images of lung ventilation according to the Xe MRI CTC recommendations. Preparation and administration of 129Xe for MR studies will be discussed and demonstrated, with specific topics including choice of appropriate gas volumes for entire studies and for individual MR scans, preparation and delivery of individual 129Xe doses, and best practices for monitoring subject safety and 129Xe tolerability during studies. Key MR technical considerations will also be covered, including pulse sequence types and optimized parameters, calibration of 129Xe flip angle and center frequency, and 129Xe MRI ventilation image analysis.
引用
收藏
页数:26
相关论文
共 43 条
[1]  
[Anonymous], 2022, FDA APPROVES POLAREA
[2]   A thermally polarized 129Xe phantom for quality assurance in multi-center hyperpolarized gas MRI studies [J].
Bier, Elianna A. ;
Nouls, John C. ;
Wang, Ziyi ;
He, Mu ;
Schrank, Geoff ;
Morales-Medina, Naomi ;
Hashoian, Ralph ;
Svetlik, Harvey ;
Mugler, John P., III ;
Driehuys, Bastiaan .
MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (05) :1961-1968
[3]   3D diffusion-weighted 129Xe MRI for whole lung morphometry [J].
Chan, Ho-Fung ;
Stewart, Neil J. ;
Norquay, Graham ;
Collier, Guilhem J. ;
Wild, Jim M. .
MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (06) :2986-2995
[4]   Hyperpolarized 129Xe MR Imaging of Alveolar Gas Uptake in Humans [J].
Cleveland, Zackary I. ;
Cofer, Gary P. ;
Metz, Gregory ;
Beaver, Denise ;
Nouls, John ;
Kaushik, S. Sivaram ;
Kraft, Monica ;
Wolber, Jan ;
Kelly, Kevin T. ;
McAdams, H. Page ;
Driehuys, Bastiaan .
PLOS ONE, 2010, 5 (08)
[5]   Single breath-held acquisition of coregistered 3D 129Xe lung ventilation and anatomical proton images of the human lung with compressed sensing [J].
Collier, Guilhem J. ;
Hughes, Paul J. C. ;
Horn, Felix C. ;
Chan, Ho-Fung ;
Tahir, Bilal ;
Norquay, Graham ;
Stewart, Neil J. ;
Wild, Jim M. .
MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (01) :342-347
[6]   The Clinical Use of Lung MRI in Cystic Fibrosis What, Now, How? [J].
Dournes, Gael ;
Walkup, Laura L. ;
Benlala, Ilyes ;
Willmering, Matthew M. ;
Macey, Julie ;
Bui, Stephanie ;
Laurent, Francois ;
Woods, Jason C. .
CHEST, 2021, 159 (06) :2205-2217
[7]   Chronic Obstructive Pulmonary Disease: Safety and Tolerability of Hyperpolarized 129Xe MR Imaging in Healthy Volunteers and Patients [J].
Driehuys, Bastiaan ;
Martinez-Jimenez, Santiago ;
Cleveland, Zackary I. ;
Metz, Gregory M. ;
Beaver, Denise M. ;
Nouls, John C. ;
Kaushik, S. Sivaram ;
Firszt, Rafael ;
Willis, Christine ;
Kelly, Kevin T. ;
Wolber, Jan ;
Kraft, Monica ;
McAdams, H. Page .
RADIOLOGY, 2012, 262 (01) :279-289
[8]   The role of hyperpolarized 129xenon in MR imaging of pulmonary function [J].
Ebner, Lukas ;
Kammerman, Jeff ;
Driehuys, Bastiaan ;
Schiebler, Mark L. ;
Cadman, Robert V. ;
Fain, Sean B. .
EUROPEAN JOURNAL OF RADIOLOGY, 2017, 86 :343-352
[9]   Hyperpolarized 129Xenon Magnetic Resonance Imaging to Quantify Regional Ventilation Differences in Mild to Moderate Asthma A Prospective Comparison Between Semiautomated Ventilation Defect Percentage Calculation and Pulmonary Function Tests [J].
Ebner, Lukas ;
He, Mu ;
Virgincar, Rohan S. ;
Heacock, Timothy ;
Kaushik, Suryanarayanan S. ;
Freemann, Matthew S. ;
McAdams, H. Page ;
Kraft, Monica ;
Driehuys, Bastiaan .
INVESTIGATIVE RADIOLOGY, 2017, 52 (02) :120-127
[10]   3D Single-Breath Chemical Shift Imaging Hyperpolarized Xe-129 MRI of Healthy, CF, IPF, and COPD Subjects [J].
Guan, Steven ;
Tustison, Nick ;
Qing, Kun ;
Shim, Yun Michael ;
Mugler, John, III ;
Altes, Talissa ;
Albon, Dana ;
Froh, Deborah ;
Mehrad, Borna ;
Patrie, James ;
Ropp, Alan ;
Miller, Braden ;
Nehrbas, Jill ;
Mata, Jaime .
TOMOGRAPHY, 2022, 8 (05) :2574-2587