Design optimization of a solar system integrated double-skin fagade for a clustered housing unit

被引:18
作者
Barone, G. [1 ]
Vassiliades, C. [2 ]
Elia, C. [3 ]
Savvides, A. [3 ]
Kalogirou, S. [4 ]
机构
[1] Univ Naples Federico II, Dept Ind Engn, Ple Tecchio 80, I-80125 Naples, Italy
[2] Neapolis Univ Pafos, Dept Architecture Land Environm Sci, 2 Danais Ave, CY-8042 Pafos, Cyprus
[3] Univ Cyprus, Dept Architecture, POB 20537, CY-1678 Nicosia, Cyprus
[4] Cyprus Univ Technol, Dept Mech Engn & Mat Sci & Engn, 30 Archbishop Kyprianos Str, CY-3036 Limassol, Cyprus
关键词
Building integration; Double fagade; Energy analysis; Sustainable architecture; Building integrated photovoltaic-thermal; ENERGY PERFORMANCE; RENEWABLE ENERGY; THERMAL PERFORMANCE; HEAT-PUMP; FACADE; SIMULATION; COLLECTOR; COMFORT; HOT; BUILDINGS;
D O I
10.1016/j.renene.2023.119023
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The study compares a conventional double fagade (DF), a building-integrated photovoltaic double fagade (BIPV DF), and building-integrated photovoltaic thermal double fagade (BIPVT DF), by considering the impact of the depth of the cavity between the photovoltaic system and the fagade. The problematization aims at augmenting the function of an interstitial spaces between building envelope and programmed space both in terms of spatial expansion, but also in terms of energy production. The approach involves examining this space in terms of its spatial parameters and ability to accept an architecturally integrated solar system. To conduct the present analyses, three distinct systems were employed and applied to a sample thermal zone, where the cavity space shaped by the double fagade was considered as a veranda space. The energy systems were modelled utilizing the commercial software DesignBuilder, and various dynamic simulations were performed using the building energy simulation software EnergyPlus for a representative South-Eastern Mediterranean weather zone. A parametric analysis was conducted, which involved varying the cavity depths from 0.25 m to 1.50 m. Results show that the conventional DF system demonstrates lower heating demands than the other systems, whereas the opposites occur for the cooling needs. Furthermore, an increase in the cavity depth between the PV system and the fagade resulted in an increase in heating thermal loads and a decrease in cooling loads. The primary energy minimization approach provided interesting results, including the optimal depth cavity of the veranda (0.97 m).
引用
收藏
页数:12
相关论文
共 70 条
[61]   Energy renovation of an existing building in Nicosia Cyprus and investigation of the passive contribution of a BIPV/T double facade system: A case-study [J].
Theokli, Constantina ;
Elia, Christina ;
Markou, Markos ;
Vassiliades, Constantinos .
ENERGY REPORTS, 2021, 7 :8522-8533
[62]   Assessment of the electrical and thermal performances of building integrated bifacial photovoltaic modules [J].
Tina, Giuseppe Marco ;
Scavo, Fausto Bontempo ;
Aneli, Stefano ;
Gagliano, Antonio .
JOURNAL OF CLEANER PRODUCTION, 2021, 313
[63]   Building integration of active solar energy systems for facades renovation in the urban fabric: Effects on the thermal comfort in outdoor public spaces in Naples and Thessaloniki [J].
Vassiliades, C. ;
Savvides, A. ;
Buonomano, A. .
RENEWABLE ENERGY, 2022, 190 :30-47
[64]   Building integration of active solar energy systems: A review of geometrical and architectural characteristics [J].
Vassiliades, C. ;
Agathokleous, R. ;
Barone, G. ;
Forzano, C. ;
Giuzio, G. F. ;
Palombo, A. ;
Buonomano, A. ;
Kalogirou, S. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2022, 164
[65]   Assessment of an innovative plug and play PV/T system integrated in a prefabricated house unit: Active and passive behaviour and life cycle cost analysis [J].
Vassiliades, C. ;
Barone, G. ;
Buonomano, A. ;
Forzano, C. ;
Giuzio, G. F. ;
Palombo, A. .
RENEWABLE ENERGY, 2022, 186 :845-863
[66]   A Roadmap for the Integration of Active Solar Systems into Buildings [J].
Vassiliades, Constantinos ;
Kalogirou, Soteris ;
Michael, Aimilios ;
Savvides, Andreas .
APPLIED SCIENCES-BASEL, 2019, 9 (12)
[67]   Novel triangle flat plate solar thermal collector for facades integration [J].
Visa, Ion ;
Moldovan, Macedon ;
Duta, Anca .
RENEWABLE ENERGY, 2019, 143 :252-262
[68]   Environmental assessments and economic performance of BAPV and BIPV systems in Shanghai [J].
Wang, Wenli ;
Liu, Yongsheng ;
Wu, Xinfang ;
Xu, Yan ;
Yu, Wenying ;
Zhao, Chunjiang ;
Zhong, Yunbo .
ENERGY AND BUILDINGS, 2016, 130 :98-106
[69]   Performance assessment of BIPV/T double-skin facade for various climate zones in Australia: Effects on energy consumption [J].
Yang, Siliang ;
Cannavale, Alessandro ;
Di Carlo, Aldo ;
Prasad, Deo ;
Sproul, Alistair ;
Fiorito, Francesco .
SOLAR ENERGY, 2020, 199 :377-399
[70]   Design and overall energy performance of a ventilated photovoltaic facade [J].
Yun, Geun Young ;
McEvoy, Mike ;
Steemers, Koen .
SOLAR ENERGY, 2007, 81 (03) :383-394