Design optimization of a solar system integrated double-skin fagade for a clustered housing unit

被引:18
作者
Barone, G. [1 ]
Vassiliades, C. [2 ]
Elia, C. [3 ]
Savvides, A. [3 ]
Kalogirou, S. [4 ]
机构
[1] Univ Naples Federico II, Dept Ind Engn, Ple Tecchio 80, I-80125 Naples, Italy
[2] Neapolis Univ Pafos, Dept Architecture Land Environm Sci, 2 Danais Ave, CY-8042 Pafos, Cyprus
[3] Univ Cyprus, Dept Architecture, POB 20537, CY-1678 Nicosia, Cyprus
[4] Cyprus Univ Technol, Dept Mech Engn & Mat Sci & Engn, 30 Archbishop Kyprianos Str, CY-3036 Limassol, Cyprus
关键词
Building integration; Double fagade; Energy analysis; Sustainable architecture; Building integrated photovoltaic-thermal; ENERGY PERFORMANCE; RENEWABLE ENERGY; THERMAL PERFORMANCE; HEAT-PUMP; FACADE; SIMULATION; COLLECTOR; COMFORT; HOT; BUILDINGS;
D O I
10.1016/j.renene.2023.119023
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The study compares a conventional double fagade (DF), a building-integrated photovoltaic double fagade (BIPV DF), and building-integrated photovoltaic thermal double fagade (BIPVT DF), by considering the impact of the depth of the cavity between the photovoltaic system and the fagade. The problematization aims at augmenting the function of an interstitial spaces between building envelope and programmed space both in terms of spatial expansion, but also in terms of energy production. The approach involves examining this space in terms of its spatial parameters and ability to accept an architecturally integrated solar system. To conduct the present analyses, three distinct systems were employed and applied to a sample thermal zone, where the cavity space shaped by the double fagade was considered as a veranda space. The energy systems were modelled utilizing the commercial software DesignBuilder, and various dynamic simulations were performed using the building energy simulation software EnergyPlus for a representative South-Eastern Mediterranean weather zone. A parametric analysis was conducted, which involved varying the cavity depths from 0.25 m to 1.50 m. Results show that the conventional DF system demonstrates lower heating demands than the other systems, whereas the opposites occur for the cooling needs. Furthermore, an increase in the cavity depth between the PV system and the fagade resulted in an increase in heating thermal loads and a decrease in cooling loads. The primary energy minimization approach provided interesting results, including the optimal depth cavity of the veranda (0.97 m).
引用
收藏
页数:12
相关论文
共 70 条
[11]   Study of a building integrated bifacial photovoltaic facade [J].
Assoa, Ya Brigitte ;
Thony, Philippe ;
Messaoudi, Paul ;
Schmitt, Emmanuel ;
Bizzini, Olivier ;
Gelibert, Stephane ;
Therme, Didier ;
Rudy, Julie ;
Chabuel, Fabien .
SOLAR ENERGY, 2021, 227 (227) :497-515
[12]   Assessing active and passive effects of fa ade building integrated photovoltaics/thermal systems: Dynamic modelling and simulation [J].
Athienitis, Andreas K. ;
Barone, Giovanni ;
Buonomano, Annamaria ;
Palombo, Adolfo .
APPLIED ENERGY, 2018, 209 :355-382
[13]   A Review on Building Integrated Photovoltaic Facade Customization Potentials [J].
Attoye, Daniel Efurosibina ;
Aoul, Kheira Anissa Tabet ;
Hassan, Ahmed .
SUSTAINABILITY, 2017, 9 (12)
[14]  
Barone G, 2019, SOLAR HYDROGEN PRODUCTION: PROCESSES, SYSTEMS AND TECHNOLOGIES, P151, DOI 10.1016/B978-0-12-814853-2.00006-0
[15]   Experimentation, modelling and applications of a novel low-cost air-based photovoltaic thermal collector prototype [J].
Barone, Giovanni ;
Buonomano, Annamaria ;
Forzano, Cesare ;
Palombo, Adolfo ;
Panagopoulos, Orestis .
ENERGY CONVERSION AND MANAGEMENT, 2019, 195 :1079-1097
[16]   Modeling and simulation of a photovoltaic/thermal air collector assisting a facade integrated small scale heat pump with radiant PCM panel [J].
Bigaila, E. ;
Athienitis, A. K. .
ENERGY AND BUILDINGS, 2017, 149 :298-309
[17]   The role of solar cooling for nearly zero energy multifamily buildings: Performance analysis across different climates [J].
Bilardo, Matteo ;
Ferrara, Maria ;
Fabrizio, Enrico .
RENEWABLE ENERGY, 2022, 194 :1343-1353
[18]   Investigation on energy performance of double skin facade in Hong Kong [J].
Chan, A. L. S. ;
Chow, T. T. ;
Fong, K. F. ;
Lin, Z. .
ENERGY AND BUILDINGS, 2009, 41 (11) :1135-1142
[19]   Research of BIPV optimal tilted angle, use of latitude concept for south orientated plans [J].
Cheng, C. L. ;
Jimenez, Charles S. Sanchez ;
Lee, Meng-Chieh .
RENEWABLE ENERGY, 2009, 34 (06) :1644-1650
[20]   Energy performance of a ventilated double skin facade with PCM under different climates [J].
de Gracia, Alvaro ;
Navarro, Lidia ;
Castell, Albert ;
Cabeza, Luisa F. .
ENERGY AND BUILDINGS, 2015, 91 :37-42