Variations in Concurrent Validity of Two Independent Inertial Measurement Units Compared to Gold Standard for Upper Body Posture during Computerised Device Use

被引:4
作者
Lee, Roger [1 ,2 ]
Akhundov, Riad [1 ,3 ,4 ]
James, Carole [5 ]
Edwards, Suzi [2 ,6 ]
Snodgrass, Suzanne J. [1 ,2 ]
机构
[1] Univ Newcastle, Coll Hlth Med & Wellbeing, Sch Hlth Sci, Callaghan, NSW 2308, Australia
[2] Hunter Med Res Inst, Act Living Res Program, New Lambton Hts, NSW 2305, Australia
[3] Griffith Univ, Menzies Hlth Inst Queensland, Griffith Ctr Biomed & Rehabil Engn GCORE, Gold Coast, Qld 4222, Australia
[4] Griffith Univ, Sch Hlth Sci & Social Work, Gold Coast, Qld 4222, Australia
[5] Univ Sydney, Fac Med & Hlth, Sydney Sch Hlth Sci, Discipline Occupat Therapy, Newcastle, NSW 2308, Australia
[6] Univ Sydney, Fac Med & Hlth, Sch Hlth Sci, Discipline Exercise & Sport Sci, Sydney, NSW 2006, Australia
关键词
validation; inertial measurement unit; upper body posture; posture; computer use; wearables; MUSCLE ACTIVITIES; JOINT KINEMATICS; NECK PAIN; RELIABILITY; SYSTEM; SENSORS; WORK; DISTURBANCES; VALIDATION; ACCURACY;
D O I
10.3390/s23156761
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Inertial measurement units (IMUs) may provide an objective method for measuring posture during computer use, but research is needed to validate IMUs' accuracy. We examine the concurrent validity of two different IMU systems in measuring three-dimensional (3D) upper body posture relative to a motion capture system (Mocap) as a potential device to assess postures outside a laboratory environment. We used 3D Mocap and two IMU systems (Wi-Fi and Bluetooth) to capture the upper body posture of twenty-six individuals during three physical computer working conditions (monitor correct, monitor raised, and laptop). Coefficient of determination (R-2) and root-mean-square error (RMSE) compared IMUs to Mocap. Head/neck segment [HN], upper trunk segment [UTS], and joint angle [HN-UTS] were the primary variables. Wi-Fi IMUs demonstrated high validity for HN and UTS (sagittal plane) and HN-UTS (frontal plane) for all conditions, and for HN rotation movements (both for the monitor correct and monitor raised conditions), others moderate to poor. Bluetooth IMUs for HN, and UTS (sagittal plane) for the monitor correct, laptop, and monitor raised conditions were moderate. Frontal plane movements except UTS (monitor correct and laptop) and all rotation had poor validity. Both IMU systems were affected by gyroscopic drift with sporadic data loss in Bluetooth IMUs. Wi-Fi IMUs had more acceptable accuracy when measuring upper body posture during computer use compared to Mocap, except for trunk rotations. Variation in IMU systems' performance suggests validation in the task-specific movement(s) is essential.
引用
收藏
页数:15
相关论文
共 64 条
  • [1] Validity and reliability of an iPad with a three-dimensional camera for posture imaging
    Agustsson, A.
    Gislason, M. K.
    Ingvarsson, P.
    Rodby-Bousquet, E.
    Sveinsson, Th
    [J]. GAIT & POSTURE, 2019, 68 : 357 - 362
  • [2] Ahmad N., 2013, Int. J. Signal Process. Syst., V1, P256, DOI DOI 10.12720/IJSPS.1.2.256-262
  • [3] Non-invasive assessment of soft-tissue artifact and its effect on knee joint kinematics during functional activity
    Akbarshahi, Massoud
    Schache, Anthony G.
    Fernandez, Justin W.
    Baker, Richard
    Banks, Scott
    Pandy, Marcus G.
    [J]. JOURNAL OF BIOMECHANICS, 2010, 43 (07) : 1292 - 1301
  • [4] Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity
    Al-Amri, Mohammad
    Nicholas, Kevin
    Button, Kate
    Sparkes, Valerie
    Sheeran, Liba
    Davies, Jennifer L.
    [J]. SENSORS, 2018, 18 (03):
  • [5] INERTIAL MOTION SENSORS USING THE VIMOVE© SYSTEM IS A VALID METHOD TO ASSESS SPINAL MOBILITY IN PATIENTS WITH AXIAL SPONDYLOARTHRITIS
    Aranda-Valera, I. C.
    Garrido-Castro, J. L.
    Martinez-Sanchez, I.
    Gonzalez, C.
    Gardiner, P.
    Machado, P. M.
    Collantes, E.
    [J]. ANNALS OF THE RHEUMATIC DISEASES, 2018, 77 : 642 - 643
  • [6] A Comparison of Inertial Measurement Unit and Motion Capture Measurements of Tibiofemoral Kinematics during Simulated Pivot Landings
    Baek, So Young
    Ajdaroski, Mirel
    Shahshahani, Payam Mirshams
    Beaulieu, Melanie L.
    Esquivel, Amanda O.
    Ashton-Miller, James A.
    [J]. SENSORS, 2022, 22 (12)
  • [7] Concurrent validity and reliability of a novel wireless inertial measurement system to assess trunk movement
    Bauer, C. M.
    Rast, F. M.
    Ernst, M. J.
    Kool, J.
    Oetiker, S.
    Rissanen, S. M.
    Suni, J. H.
    Kankaanpaa, M.
    [J]. JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2015, 25 (05) : 782 - 790
  • [8] Concurrent validity of a wearable IMU for objective assessments of functional movement quality and control of the lumbar spine
    Beange, Kristen H. E.
    Chan, Adrian D. C.
    Beaudette, Shawn M.
    Graham, Ryan B.
    [J]. JOURNAL OF BIOMECHANICS, 2019, 97
  • [9] Estimating Orientation Using Magnetic and Inertial Sensors and Different Sensor Fusion Approaches: Accuracy Assessment in Manual and Locomotion Tasks
    Bergamini, Elena
    Ligorio, Gabriele
    Summa, Aurora
    Vannozzi, Giuseppe
    Cappozzo, Aurelio
    Sabatini, Angelo Maria
    [J]. SENSORS, 2014, 14 (10) : 18625 - 18649
  • [10] Compensating for Soft-Tissue Artifact Using the Orientation of Distal Limb Segments During Electromagnetic Motion Capture of the Upper Limb
    Bons, Zachary
    Dickinson, Taylor
    Clark, Ryan
    Beardsley, Kari
    Charles, Steven K.
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2022, 144 (07):