Validating Force Sensitive Resistor Strip Sensors for Cardiorespiratory Measurement during Sleep: A Preliminary Study

被引:7
作者
Haghi, Mostafa [1 ]
Asadov, Akhmadbek [1 ]
Boiko, Andrei [1 ]
Ortega, Juan Antonio [2 ]
Madrid, Natividad Martinez [3 ]
Seepold, Ralf [1 ]
机构
[1] HTWG Konstanz, Dept Comp Sci, Ubiquitous Comp Lab, D-78462 Constance, Germany
[2] Univ Seville, Comp Sci Dept, Seville 41012, Spain
[3] Reutlingen Univ, Sch Informat, Internet Things Lab, D-72762 Reutlingen, Germany
关键词
ballistocardiography; sleep monitoring; wavelet signal processing; heart rate; respiration rate; noninvasive sleep measurement; HEART-RATE; APNEA;
D O I
10.3390/s23083973
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Sleep disorders can impact daily life, affecting physical, emotional, and cognitive well-being. Due to the time-consuming, highly obtrusive, and expensive nature of using the standard approaches such as polysomnography, it is of great interest to develop a noninvasive and unobtrusive in-home sleep monitoring system that can reliably and accurately measure cardiorespiratory parameters while causing minimal discomfort to the user's sleep. We developed a low-cost Out of Center Sleep Testing (OCST) system with low complexity to measure cardiorespiratory parameters. We tested and validated two force-sensitive resistor strip sensors under the bed mattress covering the thoracic and abdominal regions. Twenty subjects were recruited, including 12 males and 8 females. The ballistocardiogram signal was processed using the 4th smooth level of the discrete wavelet transform and the 2nd order of the Butterworth bandpass filter to measure the heart rate and respiration rate, respectively. We reached a total error (concerning the reference sensors) of 3.24 beats per minute and 2.32 rates for heart rate and respiration rate, respectively. For males and females, heart rate errors were 3.47 and 2.68, and respiration rate errors were 2.32 and 2.33, respectively. We developed and verified the reliability and applicability of the system. It showed a minor dependency on sleeping positions, one of the major cumbersome sleep measurements. We identified the sensor under the thoracic region as the optimal configuration for cardiorespiratory measurement. Although testing the system with healthy subjects and regular patterns of cardiorespiratory parameters showed promising results, further investigation is required with the bandwidth frequency and validation of the system with larger groups of subjects, including patients.
引用
收藏
页数:16
相关论文
共 71 条
[51]   Smart technologies toward sleep monitoring at home [J].
Park, Kwang Suk ;
Choi, Sang Ho .
BIOMEDICAL ENGINEERING LETTERS, 2019, 9 (01) :73-85
[52]   The future of sleep health: a data-driven revolution in sleep science and medicine [J].
Perez-Pozuelo, Ignacio ;
Zhai, Bing ;
Palotti, Joao ;
Mall, Raghvendra ;
Aupetit, Michael ;
Garcia-Gomez, Juan M. ;
Taheri, Shahrad ;
Guan, Yu ;
Fernandez-Luque, Luis .
NPJ DIGITAL MEDICINE, 2020, 3 (01)
[53]   Sleep is essential to health: an American Academy of Sleep Medicine position statement [J].
Ramar, Kannan ;
Malhotra, Raman K. ;
Carden, Kelly A. ;
Martin, Jennifer L. ;
Abbasi-Feinberg, Fariha ;
Aurora, R. Nisha ;
Kapur, Vishesh K. ;
Olson, Eric J. ;
Rosen, Carol L. ;
Rowley, James A. ;
Shelgikar, Anita, V ;
Trotti, Lynn Marie .
JOURNAL OF CLINICAL SLEEP MEDICINE, 2021, 17 (10) :2115-2119
[54]   A New Approach for Detecting Sleep Apnea Using a Contactless Bed Sensor: Comparison Study [J].
Sadek, Ibrahim ;
Heng, Terry Tan Soon ;
Seet, Edwin ;
Abdulrazak, Bessam .
JOURNAL OF MEDICAL INTERNET RESEARCH, 2020, 22 (09)
[55]   Nonintrusive Vital Signs Monitoring for Sleep Apnea Patients: A Preliminary Study [J].
Sadek, Ibrahim ;
Seet, Edwin ;
Biswas, Jit ;
Abdulrazak, Bessam ;
Mokhtari, Mounir .
IEEE ACCESS, 2018, 6 :2506-2514
[56]   A systematic review of the accuracy of sleep wearable devices for estimating sleep onset [J].
Scott, Hannah ;
Lack, Leon ;
Lovato, Nicole .
SLEEP MEDICINE REVIEWS, 2020, 49
[57]   A Minimum Set of Physiological Parameters to Diagnose Obstructive Sleep Apnea Syndrome Using Non-Invasive Portable Monitors. A Systematic Review [J].
Serrano Alarcon, Angel ;
Martinez Madrid, Natividad ;
Seepold, Ralf .
LIFE-BASEL, 2021, 11 (11)
[58]   Piezoelectric Sensor-Based Continuous Monitoring of Respiratory Rate During Sleep [J].
So, Shuhei ;
Jain, Divyanu ;
Kanayama, Naohiro .
JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2021, 41 (02) :241-250
[59]   Comparison of Pulse Wave Signal Monitoring Techniques with Different Fiber-Optic Interferometric Sensing Elements [J].
Ushakov, Nikolai ;
Markvart, Aleksandr ;
Kulik, Dania ;
Liokumovich, Leonid .
PHOTONICS, 2021, 8 (05)
[60]   Camera-Based Vital Signs Monitoring During Sleep - A Proof of Concept Study [J].
van Gastel, Mark ;
Stuijk, Sander ;
Overeem, Sebastiaan ;
van Dijk, Johannes P. ;
van Gilst, Merel M. ;
de Haan, Gerard .
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2021, 25 (05) :1409-1418