Validating Force Sensitive Resistor Strip Sensors for Cardiorespiratory Measurement during Sleep: A Preliminary Study

被引:7
作者
Haghi, Mostafa [1 ]
Asadov, Akhmadbek [1 ]
Boiko, Andrei [1 ]
Ortega, Juan Antonio [2 ]
Madrid, Natividad Martinez [3 ]
Seepold, Ralf [1 ]
机构
[1] HTWG Konstanz, Dept Comp Sci, Ubiquitous Comp Lab, D-78462 Constance, Germany
[2] Univ Seville, Comp Sci Dept, Seville 41012, Spain
[3] Reutlingen Univ, Sch Informat, Internet Things Lab, D-72762 Reutlingen, Germany
关键词
ballistocardiography; sleep monitoring; wavelet signal processing; heart rate; respiration rate; noninvasive sleep measurement; HEART-RATE; APNEA;
D O I
10.3390/s23083973
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Sleep disorders can impact daily life, affecting physical, emotional, and cognitive well-being. Due to the time-consuming, highly obtrusive, and expensive nature of using the standard approaches such as polysomnography, it is of great interest to develop a noninvasive and unobtrusive in-home sleep monitoring system that can reliably and accurately measure cardiorespiratory parameters while causing minimal discomfort to the user's sleep. We developed a low-cost Out of Center Sleep Testing (OCST) system with low complexity to measure cardiorespiratory parameters. We tested and validated two force-sensitive resistor strip sensors under the bed mattress covering the thoracic and abdominal regions. Twenty subjects were recruited, including 12 males and 8 females. The ballistocardiogram signal was processed using the 4th smooth level of the discrete wavelet transform and the 2nd order of the Butterworth bandpass filter to measure the heart rate and respiration rate, respectively. We reached a total error (concerning the reference sensors) of 3.24 beats per minute and 2.32 rates for heart rate and respiration rate, respectively. For males and females, heart rate errors were 3.47 and 2.68, and respiration rate errors were 2.32 and 2.33, respectively. We developed and verified the reliability and applicability of the system. It showed a minor dependency on sleeping positions, one of the major cumbersome sleep measurements. We identified the sensor under the thoracic region as the optimal configuration for cardiorespiratory measurement. Although testing the system with healthy subjects and regular patterns of cardiorespiratory parameters showed promising results, further investigation is required with the bandwidth frequency and validation of the system with larger groups of subjects, including patients.
引用
收藏
页数:16
相关论文
共 71 条
[1]   Development of FBG pressure sensors using FDM technique for monitoring sleeping postures [J].
Abro, Zamir Ahmed ;
Hong, Chengyu ;
Zhang, Yifan ;
Siddiqui, Muhammad Qasim ;
Abbasi, Abdul Malik Rehan ;
Abro, Zafarullah ;
Tariq, Syed Qutaba Bin .
SENSORS AND ACTUATORS A-PHYSICAL, 2021, 331
[2]   Sleep disorders in children with Angelman and Smith-Magenis syndromes: The assessment of potential causes of disrupted settling and night time waking [J].
Agar, Georgie ;
Oliver, Chris ;
Trickett, Jayne ;
Licence, Lucy ;
Richards, Caroline .
RESEARCH IN DEVELOPMENTAL DISABILITIES, 2020, 97
[3]   Bed-Embedded Heart and Respiration Rates Detection by Longitudinal Ballistocardiography and Pattern Recognition [J].
Albukhari, Almothana ;
Lima, Frederico ;
Mescheder, Ulrich .
SENSORS, 2019, 19 (06)
[4]  
Arand DL, 2019, HAND CLINIC, V160, P393, DOI 10.1016/B978-0-444-64032-1.00026-6
[5]   Personalized Maternal Sleep Quality Assessment: An Objective IoT-based Longitudinal Study [J].
Azimi, Iman ;
Oti, Olugbenga ;
Labbaf, Sina ;
Niela-Vilen, Hannakaisa ;
Axelin, Anna ;
Dutt, Nikil ;
Liljeberg, Pasi ;
Rahmani, Amir M. .
IEEE ACCESS, 2019, 7 :93433-93447
[6]   Narcolepsy - clinical spectrum, aetiopathophysiology, diagnosis and treatment [J].
Bassetti, Claudio L. A. ;
Adamantidis, Antoine ;
Burdakov, Denis ;
Han, Fang ;
Gay, Steffen ;
Kallweit, Ulf ;
Khatami, Ramin ;
Koning, Frits ;
Kornum, Brigitte R. ;
Lammers, Gert Jan ;
Liblau, Roland S. ;
Luppi, Pierre H. ;
Mayer, Geert ;
Pollmaecher, Thomas ;
Sakurai, Takeshi ;
Sallusto, Federica ;
Scammell, Thomas E. ;
Tafti, Mehdi ;
Dauvilliers, Yves .
NATURE REVIEWS NEUROLOGY, 2019, 15 (09) :519-539
[7]   Accurate scoring of the apnea-hypopnea index using a simple non-contact breathing sensor [J].
Beattie, Zachary T. ;
Hayes, Tamara L. ;
Guilleminault, Christian ;
Hagen, Chad C. .
JOURNAL OF SLEEP RESEARCH, 2013, 22 (03) :356-362
[8]   Advantages of tunnel monitoring using distributed fibre optic sensing [J].
Buchmayer, Fabian ;
Monsberger, Christoph Martin ;
Lienhart, Werner .
JOURNAL OF APPLIED GEODESY, 2021, 15 (01) :1-12
[9]   Sleep and circadian rhythms: pillars of health-a Keystone Symposia report [J].
Cable, Jennifer ;
Schernhammer, Eva ;
Hanlon, Erin C. ;
Vetter, Celine ;
Cedernaes, Jonathan ;
Makarem, Nour ;
Dashti, Hassan S. ;
Shechter, Ari ;
Depner, Christopher ;
Ingiosi, Ashley ;
Blume, Christine ;
Tan, Xiao ;
Gottlieb, Elie ;
Benedict, Christian ;
Van Cauter, Eve ;
St-Onge, Marie-Pierre .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 2021, 1506 (01) :18-34
[10]   Use of polysomnography and home sleep apnea tests for the longitudinal management of obstructive sleep apnea in adults: an American Academy of Sleep Medicine clinical guidance statement [J].
Caples, Sean M. ;
Anderson, W. McDowell ;
Calero, Karel ;
Howell, Michael ;
Hashmi, Sarah D. .
JOURNAL OF CLINICAL SLEEP MEDICINE, 2021, 17 (06) :1287-1293