Low-profile visualized intraluminal support-within-Enterprise overlapping-stent technique versus flow diversion in the treatment of intracranial vertebrobasilar trunk dissecting aneurysms

被引:3
|
作者
Wu, Qiaowei [1 ]
Wang, Chunlei [1 ]
Xu, Shancai [1 ]
Ji, Zhiyong [1 ]
Qi, Jingtao [1 ]
Li, Yuchen [1 ]
Yao, Jinbiao [1 ]
Shi, Huaizhang [1 ]
Wu, Pei [1 ]
机构
[1] Harbin Med Univ, Affiliated Hosp 1, Dept Neurosurg, 23 Youzheng Rd, Harbin 150000, Heilongjiang, Peoples R China
基金
黑龙江省自然科学基金;
关键词
Vertebrobasilar aneurysms; low-profile visualized intraluminal support (LVIS); Enterprise stent; flow diverter; stent-assisted coiling; ENDOVASCULAR TREATMENT; NATURAL-HISTORY; OUTCOMES;
D O I
10.21037/qims-22-970
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: It is necessary to explore the safety and efficacy of various endovascular treatment techniques in the treatment of patients with intracranial vertebrobasilar trunk dissecting aneurysms (VBTDAs). This study sought to compare the clinical and angiographic outcomes of patients with intracranial VBTDAs following low-profile visualized intraluminal support (LVIS)-within-Enterprise overlapping-stent technique with those of flow diversion (FD). Methods: This was a retrospective, observational, cohort study. Between January 2014 and March 2022, 9,147 patients with intracranial aneurysms were screened, and 91 patients with 95 VBTDAs who underwent LVIS-within-Enterprise overlapping-stent assisted-coiling technique or FD were included in the analysis. The primary outcome was the complete occlusion rate at the last angiographic follow-up. The secondary outcomes included adequate aneurysm occlusion, in-stent stenosis/thrombosis, general neurological complications, neurological complications within 30 days after the procedure, the mortality rate, and unfavorable outcomes. Results: Among the 91 included patients, 55 were treated with LVIS-within-Enterprise overlapping-stent technique (the LE group) and 36 were treated with FD (the FD group). The angiography results at the median follow-up time of 8 months showed complete occlusion rates of 90.0% and 60.9% for the LE and FD groups, respectively, with an adjusted odds ratio of 5.79 (95% CI: 1.35-24.85; P=0.01). Adequate aneurysm occlusion (P=0.98), in-stent stenosis/thrombosis (P=0.46), general neurological complications (P=0.22), neurological complications within 30 days after the procedure (P=0.63), mortality rate (P=0.31), and unfavorable outcomes (P=0.07) at the last clinical follow-up did not differ significantly between the 2 groups. Conclusions: A significantly higher complete occlusion rate for VBTDAs was found following LVIS-within-Enterprise overlapping- stent technique as compared with FD. The 2 treatment modalities have comparable adequate occlusion rates and safety profiles.
引用
收藏
页码:3536 / 3546
页数:11
相关论文
共 48 条
  • [21] Low-profile visible intraluminal support stent-assisted embolization therapy for intracranial dissecting aneurysms: A retrospective analysis of six cases
    Zhou Jia-Hao
    Richard, Seidu A.
    Ming Jiang
    Deng Yin-sheng
    NEUROLOGY INTERNATIONAL, 2020, 12 (02) : 19 - 23
  • [22] Utility of Low-Profile Visualized Intraluminal Support Junior Stent as a Rescue Therapy for Treating Ruptured Intracranial Aneurysms During Complicated Coil Embolization
    Kim, Seung Soo
    Park, Hyun
    Lee, Kwang Ho
    Jung, Seunguk
    Yoon, Chang Hyo
    Kim, Sung Kwon
    Ryu, Kyeong Hwa
    Baek, Hye Jin
    Hwang, Soo Hyun
    Kwon, O-Ki
    WORLD NEUROSURGERY, 2020, 135 : e710 - e715
  • [23] LVIS-within-enterprise double-stent technique with coil embolization in the treatment of patients with acutely ruptured intracranial vertebrobasilar artery-dissecting aneurysms
    Wu, Qiaowei
    Meng, Yuxiao
    Chen, Aixia
    Xu, Shancai
    Wang, Chunlei
    Ji, Zhiyong
    Qi, Jingtao
    Yuan, Kaikun
    Shao, Jiang
    Shi, Huaizhang
    Wu, Pei
    FRONTIERS IN NEUROLOGY, 2023, 14
  • [24] Long-term outcomes of Low-profile Visualized Intraluminal Support device usage in stent-assisted coiling of intracranial aneurysm
    Yoo, Dong Hyun
    Cho, Young Dae
    Moon, Jusun
    Lee, Jeongjun
    Kang, Hyun-Seung
    Cho, Won-Sang
    Kim, Jeong Eun
    Hwang, Gyojun
    Kwon, O-Ki
    Han, Moon Hee
    JOURNAL OF CLINICAL NEUROSCIENCE, 2018, 50 : 287 - 291
  • [25] Low-profile Visualized Intraluminal Support device (LVIS Jr) as a novel tool in the treatment of wide-necked intracranial aneurysms: initial experience in 32 cases
    Behme, Daniel
    Weber, Anushe
    Kowoll, Annika
    Berlis, Ansgar
    Burke, Thomas H.
    Weber, Werner
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2015, 7 (04) : 281 - 285
  • [26] Comparative analysis of long term effectiveness of Neuroform Atlas stent versus low profile visualized intraluminal stent/Woven EndoBridge devices in treatment of wide necked intracranial aneurysms
    Salem, Mohamed M.
    Jankowitz, Brian T.
    Burkhardt, Jan-Karl
    Price, Lori Lyn
    Zaidat, Osama O.
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2024, 16 (11) : 1115 - +
  • [27] Tiny Cerebral Aneurysms Can Be Treated Safely and Effectively with Low-Profile Visualized Intraluminal Support Stent-Assisted Coiling or Coiling Alone
    Gao, Bu-Lang
    Li, Tian-Xiao
    Li, Li
    Xu, Gang-Qin
    Yang, Bo-Wen
    WORLD NEUROSURGERY, 2018, 113 : E426 - E430
  • [28] Three-dimensional fusion imaging to assess apposition of low-profile visualized intraluminal support stent for intracranial aneurysm coiling
    Kato, Naoki
    Ishibashi, Toshihiro
    Otani, Katharina
    Abe, Yukiko
    Sano, Tohru
    Nagayama, Gota
    Fuga, Michiyasu
    Hataoka, Shunsuke
    Kan, Issei
    Murayama, Yuichi
    WORLD NEUROSURGERY-X, 2024, 23
  • [29] Using overlapping low-profile visualized intraluminal support stent-assisted coil embolization for treating blood blister-like aneurysms of the internal carotid artery
    Zhang, Xiang
    Shen, Rui
    Zhao, Jingjing
    Sun, Jiping
    Zhang, Quanbin
    Chen, Zuoquan
    NEUROSURGICAL REVIEW, 2021, 44 (02) : 1053 - 1060
  • [30] Treatment of wide-necked aneurysms with the Low-profile Visualized Intraluminal Support (LVIS Jr) device: a multicenter experience
    Grossberg, J. A.
    Hanel, R. A.
    Dabus, G.
    Keigher, K.
    Haussen, D. C.
    Sauvageau, E.
    Linfante, I.
    Gonsales, D.
    Salinas, P. Aguilar
    Bouslama, M.
    Mayich, M.
    Nogueira, R. G.
    Lopes, D. K.