Biomechanical study of internal fixation methods for femoral neck fractures based on Pauwels angle

被引:12
作者
Wang, Fuyang [1 ]
Liu, Yuchen [1 ]
Huo, Yi [2 ]
Wang, Ziming [1 ]
Zhang, Jinge [3 ]
Xu, Minghao [1 ]
Ma, Kaiming [1 ]
Wang, Linbao [1 ]
Lu, Yongtao [2 ]
Cheng, Liangliang [1 ]
Zhao, Dewei [1 ]
机构
[1] Dalian Univ, Affiliated Zhongshan Hosp, Dept Orthoped, Dalian, Peoples R China
[2] Dalian Univ Technol, Dept Engn Mech, Dalian, Peoples R China
[3] Dalian Univ, Affiliated Zhongshan Hosp, Dept Anesthesiol, Dalian, Peoples R China
关键词
femoral neck fractures; finite element analysis; biomechanics; medial buttress plate; cannulated compression screws; porous tantalum screws; MECHANICAL STIMULATION; FINITE-ELEMENT; HIP SCREW; ADULTS;
D O I
10.3389/fbioe.2023.1143575
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Objective: To select the most appropriate internal fixation method based on the Pauwels angle, in order to provide a new concept for clinical accurate treatment of femoral neck fractures (FNFs). Methods: FNFs models of Pauwels 30 degrees; 40 degrees; 50 degrees; 60 degrees were created respectively. For Pauwels <= 50 degrees, 1, 2 and 3 Cannulated Compression Screws (CCS) and Porous Tantalum Screws (PTS) were used to fix the fracture for the models. For Pauwels 60 degrees, 3CCS and Medial Buttress Plate (MBP) combined with 1, 2 and 3CCS were used to fix the fracture. Based on the results of the finite element (FE) analysis, the biomechanical properties of each model were compared by analyzing and evaluating the following four parameters: maximal stress of the bone (MBS), maximal stress of the implants (MIS), maximal displacement of bone (MBD), interfragmentary motion (IFM). Results: At Pauwels 30 degrees, the larger parameters were found in 1CCS, which was 94.8 MPa (MBS), 307.7 MPa (MIS), 0.86 mm (MBD) and 0.36 mm (IFM). In 2CCS group, the parameters were 86.1 MPa (MBS), 254.4 MPa (MIS), 0.73 mm (MBD) and 0.27 mm (IFM), which were similar to those of PTS. At Pauwels 40 degrees; 50 degrees, with the increase of the number of used CCS, accordingly, the parameters decreased. Particularly, the MIS (Pauwels 50 degrees) of 1CCS was 1,195.3 MPa, but the other were less than the yield range of the materials. At Pauwels 60 degrees, the MBS of 3CCS group was 128.6 Mpa, which had the risk of failure. In 2CCS + MBP group, the parameters were 124.2 MPa (MBS), 602.5 MPa (MIS), 0.75 mm (MBD) and 0.48 mm (IFM), The model stability was significantly enhanced after adding MBP. Conclusion: Pauwels type I (< 30 degrees) fractures can reduce the number of CCS, and PTS is an appropriate alternative treatment. For Pauwels type II fractures (30 degrees similar to 50 degrees), the 3CCS fixation method is still recommended. For Pauwels type III fractures (> 50 degrees), it is recommended to add MBP to the medial femoral neck and combine with 2CCS to establish a satisfactory fracture healing environment.
引用
收藏
页数:11
相关论文
共 30 条
[1]   Vertically oriented femoral neck fractures: Mechanical analysis of four fixation techniques [J].
Aminian, Arash ;
Gao, Fan ;
Fedoriw, Wasyl W. ;
Zhang, Li-Qun ;
Kalainov, David M. ;
Merk, Bradley R. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (08) :544-548
[2]   Pauwels' classification of femoral neck fractures:: Correct interpretation of the original [J].
Bartonícek, J .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2001, 15 (05) :358-360
[3]  
Berkes MB, 2013, J BONE JOINT SURG AM, V95A, P1769, DOI [10.2106/JBJS.L.00401, 10.2106/JBJS.L.00949, 10.2106/JBJS.L.00012, 10.2106/JBJS.L.01185]
[4]   Fracture fixation in the operative management of hip fractures (FAITH): an international, multicentre, randomised controlled trial [J].
Bhandari, Mohit ;
Devereaux, P. J. ;
Guyatt, Gordon ;
Thabane, Lehana ;
Walter, Stephen D. ;
Heetveld, Martin J. ;
Jeray, Kyle J. ;
Liew, Susan ;
Schemitsch, Emil H. ;
Tornetta, Paul, III ;
Della Rocca, Gregory J. ;
McCormack, Robert ;
Oliver, Todd M. ;
Segers, Michiel J. M. ;
Rangan, Amar ;
Richardson, Martin ;
Sprague, Sheila ;
Slobogean, Gerard P. ;
Scott, Taryn ;
Garibaldi, Alisha ;
Zhou, Qi ;
Heels-Ansdell, Diane ;
Viveiros, Helena ;
Zielinski, Stephanie M. ;
Van Lieshout, Esther M. M. ;
Johal, Herman ;
Hanusch, Birgit C. ;
Swiontkowski, Marc .
LANCET, 2017, 389 (10078) :1519-1527
[5]   Biomechanical Evaluation of Internal Fixation of Pauwels Type III Femoral Neck Fractures: A Systematic Review of Various Fixation Methods [J].
Cha, Yong-Han ;
Yoo, Jun-Il ;
Hwang, Seok-Young ;
Kim, Kap-Jung ;
Kim, Ha-Yong ;
Choy, Won-Sik ;
Hwang, Sun-Chul .
CLINICS IN ORTHOPEDIC SURGERY, 2019, 11 (01) :1-14
[6]   Challenges in the Treatment of Femoral Neck Fractures in the Nonelderly Adult [J].
Davidovitch, Roy I. ;
Jordan, Charles J. ;
Egol, Kenneth A. ;
Vrahas, Mark S. .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2010, 68 (01) :236-242
[7]   Experimental Validation of a Finite Element Model of the Proximal Femur Using Digital Image Correlation and a Composite Bone Model [J].
Dickinson, A. S. ;
Taylor, A. C. ;
Ozturk, H. ;
Browne, M. .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2011, 133 (01)
[8]   A biomechanical evaluation of orthopaedic implants for hip fractures by finite element analysis and in-vitro tests [J].
Eberle, S. ;
Gerber, C. ;
von Oldenburg, G. ;
Hoegel, F. ;
Augat, P. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2010, 224 (H10) :1141-1152
[9]   Two Cannulated Screws Provide Sufficient Biomechanical Strength for Prophylactic Fixation in Adult Patients With an Aggressive Benign Femoral Neck Lesion [J].
Fu, Guangtao ;
Zhong, Guoqing ;
Yang, Zehong ;
Cheng, Shi ;
Ma, Limin ;
Zhang, Yu .
FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
[10]   Implicit modeling of screw threads for efficient finite element analysis of complex bone-implant systems [J].
Inzana, Jason A. ;
Varga, Peter ;
WindoIf, Markus .
JOURNAL OF BIOMECHANICS, 2016, 49 (09) :1836-1844