Photoanthropometric craniofacial parameters in individuals with osteogenesis imperfecta

被引:0
作者
Marcal, Felipe Franco [1 ]
Lopes, Luiza Lassi de Araujo [1 ]
Moreno, Lara Matos [3 ]
Freire Junior, Jorge Luiz Moreira [3 ]
Chaves Junior, Cauby Maia [2 ]
Silva, Paulo Goberlanio de Barros [4 ]
Ribeiro, Erlane Marques [5 ,6 ]
Fonteles, Cristiane Sa Roriz [7 ]
Ribeiro, Thyciana Rodrigues [2 ,8 ]
机构
[1] Univ Fed Ceara, Postgrad Program Dent, Fortaleza, Ceara, Brazil
[2] Univ Fed Ceara, Dept Clin Dent, Fortaleza, Brazil
[3] Univ Fed Ceara, Fortaleza, Ceara, Brazil
[4] Christus Univ Ctr, Sch Dent, Fortaleza, Brazil
[5] Christus Univ Ctr, Sch Med, Fortaleza, Brazil
[6] Childrens Hosp Albert Sabin, Div Genet, Fortaleza, Brazil
[7] Univ Fed Ceara, Dept Clin Dent, Fortaleza, Brazil
[8] Rua Monsenhor Furtado,S-N Rodolfo Teofilo, BR-60430355 Fortaleza, Ceara, Brazil
来源
MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL | 2024年 / 29卷 / 01期
关键词
Osteogenesis imperfecta; face; photography; MANAGEMENT; TRAITS;
D O I
10.4317/medoral.26083
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: This study aimed to evaluate facial photoanthropometric parameters in patients with OI.Material and Methods: We selected 20 Brazilian patients diagnosed with OI treated at the Extension Service for Minors in Need of Specialized Treatment of the Dentistry Course at the Federal University of Ceara (Fortaleza, Brazil), of both sexes, without age restriction, and able to understand and sign the informed consent form (ICF). As a control group, 38 non-syndromic Brazilian individuals, categorized as ASA I, able to understand and sign the ICF, matched by sex, age, and Legan and Burstone facial profile were selected. The exclusion criteria were: previ-ous orthodontic treatment, craniofacial trauma and/or surgery, and the presence of any other systemic diseases. Photoanthropometric analysis of the 18 facial parameters proposed by Stengel-Rutkowski et al. (1984), previously established in the literature for craniofacial syndromes, were conducted. A single examiner digitally performed all effective and angular measurements with the CorelDRAWX7 (R) software.Results: Horizontally shortened ears (p<0.001) but larger in height in relation to the face (p= 0.012) were shown to be alterations belonging to individuals with OI.Conclusions: OI patients present distinct photoanthropometric parameters inherent in this condition.
引用
收藏
页码:e87 / e94
页数:8
相关论文
共 21 条
  • [1] Aspects of the history of osteogenesis imperfecta (Vrolik's syndrome)
    Baljet, B
    [J]. ANNALS OF ANATOMY-ANATOMISCHER ANZEIGER, 2002, 184 (01) : 1 - 7
  • [2] Butler MG, 1998, CLIN GENET, V53, P268
  • [3] PHOTOANTHROPOMETRIC ANALYSIS OF INDIVIDUALS WITH THE FRAGILE-X SYNDROME
    BUTLER, MG
    ALLEN, GA
    SINGH, DN
    CARPENTER, NJ
    HALL, BD
    [J]. AMERICAN JOURNAL OF MEDICAL GENETICS, 1988, 30 (1-2): : 165 - 168
  • [4] The craniofacial characteristics of osteogenesis imperfecta patients
    Chang, Pei-Ching
    Lin, Shiao-Yu
    Hsu, Kuang-Hung
    [J]. EUROPEAN JOURNAL OF ORTHODONTICS, 2007, 29 (03) : 232 - 237
  • [5] Comparison of three methods of facial measurement
    Ghoddousi, H.
    Edler, R.
    Haers, P.
    Wertheim, D.
    Greenhill, D.
    [J]. INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2007, 36 (03) : 250 - 258
  • [6] Gorczyca Piotr, 2012, Iran J Psychiatry, V7, P41
  • [7] Hovis CL, 1997, CLIN GENET, V51, P379
  • [8] Kindelan J, 2003, J Orthod, V30, P291, DOI 10.1093/ortho/30.4.291
  • [9] The management of osteogenesis imperfecta in adults: state of the art
    Lafage-Proust, Marie-Helene
    Courtois, Isabelle
    [J]. JOINT BONE SPINE, 2019, 86 (05) : 589 - 593
  • [10] LEGAN HL, 1980, J ORAL SURG, V38, P744