Comparison of the Shutdown Transitions of the Full-Flow Pump and Axial-Flow Pump

被引:5
作者
Jiao, Haifeng [1 ]
Shan, Jilian [2 ]
Yang, Guorui [2 ]
Wang, Mengcheng [3 ]
Chen, Songshan [3 ]
机构
[1] Yangzhou Univ, Coll Hydraul Sci & Engn, Yangzhou 225000, Peoples R China
[2] Shandong Survey & Design Inst Water Conservancy Co, Jinan 250000, Peoples R China
[3] Yangzhou Univ, Coll Elect Energy & Power Engn, Yangzhou 225000, Peoples R China
基金
中国国家自然科学基金;
关键词
full-flow pump; axial-flow pump; shutdown transition; model test; omega vortex; entropy production; EXTENSION TUBULAR PUMP; CENTRIFUGAL PUMP; TRANSIENT CHARACTERISTICS; NUMERICAL-SIMULATION; START-UP; TURBINE; MODEL; BEHAVIOR;
D O I
10.3390/jmse11112129
中图分类号
U6 [水路运输]; P75 [海洋工程];
学科分类号
0814 ; 081505 ; 0824 ; 082401 ;
摘要
In this study, a comparative analysis of the shutdown transitions of a full-flow pump and an axial-flow pump was carried out through numerical simulation and model tests. The UDF method was used to achieve control of the impeller rotational speed during shutdown. The results show that during the shutdown transition, the rate of decline of rotational speed, flow rate, and torque of the axial-flow pump are greater than those of the full-flow pump, so the axial-flow pump stops faster than the full-flow pump. The axial force of the axial-flow pump is significantly lower than that of the full-flow pump, and the maximum value of the radial force of the axial-flow pump is approximately 1.14 times that of the full-flow pump. Due to the influence of the clearance backflow vortex, the impeller inlet and outlet of the full-flow pump generate clearance backflow vortices in the near-wall area, resulting in the overall flow pattern of the impeller chamber being worse than that of the axial-flow pump and the hydraulic loss being greater than that of the axial-flow pump. The runaway speed and flow rate of the axial-flow pump are higher than those of the full-flow pump. Due to the influence of the clearance backflow, the range of the high entropy production rate at the suction side of the impeller of the full-flow pump is always larger than that of the axial-flow pump. The research results in this paper can provide theoretical support for the selection and operation of pumps in large low-head pumping stations.
引用
收藏
页数:27
相关论文
共 57 条
  • [1] Abonai C., 2011, Express Water Resour. Hydropower Inf, V32, P29, DOI [10.15974/j.cnki.slsdkb.2011.09.008, DOI 10.15974/J.CNKI.SLSDKB.2011.09.008]
  • [2] [Anonymous], 2010, J. Drain. Irrig. Mach. Eng
  • [3] Pressure Fluctuation Characteristics Analysis of Centrifugal Pump as Turbine in Its Start-Up Process
    Chai, Baodui
    Yang, Junhu
    Wang, Xiaohui
    Jiang, Bingxiao
    [J]. ACTUATORS, 2022, 11 (05)
  • [4] Chen Song-shan, 2009, Journal of Yangzhou University (Natural Science Edition), V12, P74
  • [5] [陈松山 CHEN Songshan], 2007, [水力发电学报, Journal of Hydroelectric Engineering], V26, P128
  • [6] Wake dynamic characteristics of windproof structures in embankment-bridge sections along a high-speed railway under natural strong crosswinds
    Deng, E.
    Yue, Huan
    Ni, Yi-Qing
    He, Xu-Hui
    Yang, Wei-Chao
    Chen, Zheng-Wei
    [J]. PHYSICS OF FLUIDS, 2023, 35 (05)
  • [7] A turbulent crosswind simulation method at high-speed railway tunnel entrance: Based on field test and geometric turbulence generator
    Deng, E.
    Yue, Huan
    Ni, Yi-Qing
    Wang, You-Wu
    He, Xu-Hui
    Chen, Zheng-Wei
    [J]. PHYSICS OF FLUIDS, 2023, 35 (01)
  • [8] Research on Energy Loss Characteristics of Pump-Turbine during Abnormal Shutdown
    Deng, Yuxuan
    Xu, Jing
    Li, Yanna
    Zhang, Yanli
    Kuang, Chunyan
    [J]. PROCESSES, 2022, 10 (08)
  • [9] Experimental and numerical study of a vertical axis tidal turbine performance
    Derakhshan, Shahram
    Ashoori, Mohammadreza
    Salemi, Amirhosein
    [J]. OCEAN ENGINEERING, 2017, 137 : 59 - 67
  • [10] New normalized Rortex/vortex identification method
    Dong, Xiangrui
    Gao, Yisheng
    Liu, Chaoqun
    [J]. PHYSICS OF FLUIDS, 2019, 31 (01)