共 51 条
Forced boiling of nonazeotropic immiscible mixture in a supercapillary microchannel array for ultra-high heat flux removal with chip junction temperature below 85°C
被引:1
作者:
Sun, Bo
[1
]
Bao, YuChen
[1
]
Tian, Tong
[1
]
Li, Ji
[2
]
机构:
[1] Univ Chinese Acad Sci, Sch Engn Sci, Beijing 100049, Peoples R China
[2] Univ Chinese Acad Sci, Sch Engn Sci, Lab Adv Thermal Management Technol, Beijing 100049, Peoples R China
基金:
中国国家自然科学基金;
关键词:
microchannel;
sintered powder coating;
submicron nucleation cavities;
nonazeotropic immiscible;
ultra-high heat flux;
DIVERGING MICROCHANNEL;
WATER MIXTURES;
PRESSURE-DROP;
FLOW;
SINK;
ENHANCEMENT;
PERFORMANCE;
ELECTRONICS;
INSTABILITY;
NANOFLUID;
D O I:
10.1007/s11431-023-2511-x
中图分类号:
T [工业技术];
学科分类号:
08 ;
摘要:
In this study, a structure-optimized two-phase microchannel heat sink with sintered submicron nucleation sites was developed and tested. The copper-based microchannels had a rectangular cross-section with an equivalent hydraulic diameter of 222 mu m. The subcooled flow boiling characteristics were comprehensively compared between pure HFE-7100 and a non-azeotropic, immiscible binary mixture of HFE-7100 and water, considering heating areas of 1 and 5 cm(2). The total heating power input to the test section were 100-1500 and 250-3000 W for a 1 and 5 cm(2) heat source, respectively, with a flow rate ranging from 50 to 150 L/h. Compared to pure HFE-7100, the non-azeotropic immiscible binary mixture of HFE-7100/water in the sintered porous microchannels exhibited a much higher overall heat transfer coefficient and lower power consumption. To maintain the junction temperature of a high power electronic chip below 85 degrees C, the proposed supercapillary microchannel heat sink could effectively dissipate the heat flux of 1275 W/cm(2) over 1 cm(2) heat source and 500 W/cm(2) over 5 cm(2) heat source. In addition, the volume ratio of the binary mixture strongly influence the two-phase flow heat transfer characteristics. An optimal volume ratio exist in terms of the thermal resistance-pumping power minimization (HFE-7100:water=2:8 is recommended in this study). The findings of this investigation on the flow boiling properties of non-azeotropic immiscible mixtures help fill a gap in the related field.
引用
收藏
页码:1364 / 1380
页数:17
相关论文